Biomechanical Analysis of Cortical Bone Trajectory Screw Versus Bone Cement Screw for Fixation in Porcine Spinal Low Bone Mass Model

被引:2
作者
Li, Yifan [1 ]
Wang, Silian [2 ]
Zhu, Zhenbiao [4 ]
Chen, Liwei [2 ]
Shi, Zhangpeng [3 ]
Ye, Xiaojian [1 ]
Xu, Wei [1 ]
Li, Zhikun [1 ,5 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Orthoped, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Tongren Hosp, Sch Med, Dept Imaging, Shanghai, Peoples R China
[3] Anhui Med Univ, Shanghai Clin Coll, Shanghai, Peoples R China
[4] Cent South Univ, Dept Orthopaed, Xiangya Sch Med, Affiliated Haikou Hosp, Haikou, Hainan, Peoples R China
[5] Shanghai Tongren Hosp, Shanghai, Peoples R China
来源
CLINICAL SPINE SURGERY | 2023年 / 36卷 / 04期
关键词
cortical bone trajectory screw; bone cement screw; biomechanical analysis; porcine spinal model; PEDICLE; AUGMENTATION; PLACEMENT; ADJACENT;
D O I
10.1097/BSD.0000000000001395
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design: A prospective study of in vitro animal. Objection: To compare the biomechanics of cortical bone trajectory screw (CBT) and bone cement screw (BC) in an isolated porcine spinal low bone mass model. Summary of Background Data: The choice of spinal fixation in patients with osteoporosis remains controversial. Is CBT better than BC? Research on this issue is lacking. Methods:Ten porcine spines with 3 segments were treated with EDTA decalcification. After 8 weeks, all the models met the criteria of low bone mass. Ten specimens were randomly divided into groups, group was implanted with CBT screw (CBT group) and the other group was implanted with bone cement screw (BC group). The biomechanical material testing machine was used to compare the porcine spine activities of the two groups in flexion, extension, bending, and axial rotation, and then insertional torque, pull-out force, and anti-compression force of the 2 groups were compared. Independent sample t test was used for comparison between groups. Results: Ten 3 segments of porcine spine models with low bone mass were established, and the bone mineral density of all models was lower than 0.75 g/cm(2). There is no difference between the CBT and BC groups in flexion, extension, bending, and axial rotation angle, P>0.05. However, there were significant differences between the 2 groups and the control group, with P<0.01. The 2 groups significantly differed between the insertional torque (P=0.03) and the screw pull-out force (P=0.021). The anti-compression forces between the 2 groups have no significant difference between the two groups (P=0.946). Conclusions: The insertional torque and pull-out force of the CBT were higher than those of the BC in the isolated low bone porcine spine model. The range of motion and anti-compression ability of the model was similar between the 2 fixation methods.
引用
收藏
页码:E145 / E152
页数:8
相关论文
共 26 条
[1]   The biomechanics of pedicle screw augmentation with cement [J].
Elder, Benjamin D. ;
Lo, Sheng-Fu L. ;
Holmes, Christina ;
Goodwin, Courtney R. ;
Kosztowski, Thomas A. ;
Lina, Ioan A. ;
Locke, John E. ;
Witham, Timothy F. .
SPINE JOURNAL, 2015, 15 (06) :1432-1445
[2]   Biomechanical evaluation of a new AxiaLIF technique for two-level lumbar fusion [J].
Erkan, Serkan ;
Wu, Chunhui ;
Mehbod, Amir A. ;
Hsu, Brian ;
Pahl, Douglas W. ;
Transfeldt, Ensor E. .
EUROPEAN SPINE JOURNAL, 2009, 18 (06) :807-814
[3]   Pedicle screw loosening: a clinically relevant complication? [J].
Galbusera, Fabio ;
Volkheimer, David ;
Reitmaier, Sandra ;
Berger-Roscher, Nikolaus ;
Kienle, Annette ;
Wilke, Hans-Joachim .
EUROPEAN SPINE JOURNAL, 2015, 24 (05) :1005-1016
[4]   Prevalence of Osteoporosis Treatment and Its Effect on Post-Operative Complications, Revision Surgery and Costs After Multi-Level Spinal Fusion [J].
Jain, Nikhil ;
Labaran, Lawal ;
Phillips, Frank M. ;
Khan, Safdar N. ;
Jain, Amit ;
Kebaish, Khaled M. ;
Hassanzadeh, Hamid .
GLOBAL SPINE JOURNAL, 2022, 12 (06) :1119-1124
[5]   Clinical Effects and Complications of Pedicle Screw Augmentation with Bone Cement: Comparison of Fenestrated Screw Augmentation and Vertebroplasty Augmentation [J].
Kim, Jin Hak ;
Ahn, Dong Ki ;
Shin, Won Shik ;
Kim, Myung Jin ;
Lee, Ho Young ;
Go, Young Rok .
CLINICS IN ORTHOPEDIC SURGERY, 2020, 12 (02) :194-199
[6]   A method to develop an in vitro osteoporosis model of porcine vertebrae: histological and biomechanical study Laboratory investigation [J].
Lee, Ching-yi ;
Chan, She-Hung ;
Lai, Hung-Yi ;
Lee, Shih-Tseng .
JOURNAL OF NEUROSURGERY-SPINE, 2011, 14 (06) :789-798
[7]   Clinical efficacy of Bone Cement-injectable Cannulated Pedicle Screw Short Segment Fixation for Lumbar Spondylolisthesis with Osteoporosise [J].
Liu, Yao-yao ;
Xiao, Jun ;
Yin, Xiang ;
Liu, Ming-yong ;
Zhao, Jian-hua ;
Liu, Peng ;
Dai, Fei .
SCIENTIFIC REPORTS, 2020, 10 (01)
[8]  
Matsukawa K, 2017, SPINE SURG RELAT RES, V1, P164, DOI 10.22603/ssrr.1.2017-0006
[9]   Biomechanical evaluation of lumbar pedicle screws in spondylolytic vertebrae: comparison of fixation strength between the traditional trajectory and a cortical bone trajectory [J].
Matsukawa, Keitaro ;
Yato, Yoshiyuki ;
Imabayashi, Hideaki ;
Hosogane, Naobumi ;
Asazuma, Takashi ;
Chiba, Kazuhiro .
JOURNAL OF NEUROSURGERY-SPINE, 2016, 24 (06) :910-915
[10]   Biomechanical evaluation of fixation strength among different sizes of pedicle screws using the cortical bone trajectory: what is the ideal screw size for optimal fixation? [J].
Matsukawa, Keitaro ;
Yato, Yoshiyuki ;
Imabayashi, Hideaki ;
Hosogane, Naobumi ;
Abe, Yuichiro ;
Asazuma, Takashi ;
Chiba, Kazuhiro .
ACTA NEUROCHIRURGICA, 2016, 158 (03) :465-471