Superficial Femoral Artery in-Stent Restenosis Treated with Paclitaxel-Coated Balloon Angioplasty - Results of Three-Year Follow-Up

被引:0
|
作者
de Oliveira, Julio Cesar Peclat [1 ,7 ]
Fiorelli, Rossano Kepler Alvim [1 ]
Peclat, Ana Paula Rolim Maia [1 ]
de Oliveira, Lucas Maia Peclat [2 ]
Oliveira, Rafael [3 ]
Belczac, Sergio Quilici [4 ]
Almeida, Renato Santos [5 ]
Dalio, Marcelo Bellini [6 ]
Joviliano, Edwaldo Edner [6 ]
Gutfilen, Bianca [1 ]
机构
[1] Univ Fed Rio de Janeiro, Rio De Janeiro, RJ, Brazil
[2] Fed Univ Estate Rio de Janeiro, Rio De Janeiro, RJ, Brazil
[3] Souza Marques Tech Educ Fdn, Souza Marques Sch Med, Rio De Janeiro, RJ, Brazil
[4] IAPACE Inst, Sao Paulo, Brazil
[5] UNISUAM, Rio De Janeiro, RJ, Brazil
[6] Univ Sao Paulo, Ribeirao Preto Med Sch, Sao Paulo, SP, Brazil
[7] Ave Lucio Costa 2260,B3,Ap 3001, Rio De Janeiro, RJ, Brazil
关键词
in-stent restenosis; superficial femoral artery; endovascular treatment; peripheral artery disease; paclitaxel; drug-coated balloon; angioplasty; DRUG-ELUTING BALLOON; STANDARD BALLOON; MANAGEMENT; CLASSIFICATION; GUIDELINES; DISEASE;
D O I
10.1177/15385744231165877
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background In-stent restenosis remains a common and important complication after endovascular treatment of superficial femoral artery peripheral artery disease. It occurs in 14 to 35% of cases in 1 year and there is still no efficient treatment for this condition. Paclitaxel-coated balloons have shown promising results. Objective Investigate the 3 year results of superficial femoral artery in-stent restenosis treated with paclitaxel-coated balloon angioplasty, using the Lutonix (TM) 035 device. Methods We conducted a retrospective observational study with patients with symptomatic (Rutherford 2 to 5) superficial femoral artery in-stent restenosis, that were treated with paclitaxel-coated balloon angioplasty using the Lutonix (TM) 035 device, in a single center from January 2016 to December 2020. Duplex scan was used to follow the patients. Primary patency was obtained through Kaplan-Meier analysis. Mortality, and amputation rates were also evaluated. Results 105 patients were included. Two patients had technical failure and required an additional stent, and were thus excluded. 103 patients were analyzed. Primary patency was 91.26, 80.47, and 67.71%, respectively, in the first, second, and third year after the procedure. There were no deaths 30 days after the procedure. There were no major amputations during the 3 year follow-up. Conclusion Paclitaxel-coated balloon angioplasty with the Lutonix (TM) 035 device was a safe and effective treatment to superficial femoral artery in-stent restenoses. The results were maintained along the 3 year follow-up.
引用
收藏
页码:673 / 679
页数:7
相关论文
共 50 条
  • [1] Paclitaxel-Coated Balloon vs Uncoated Balloon Angioplasty for Treatment of In-Stent Restenosis in the Superficial Femoral and Popliteal Arteries: The COPA CABANA Trial
    Tepe, Gunnar
    Schroeder, Henrik
    Albrecht, Thomas
    Reimer, Peter
    Diehm, Nicolas
    Baeriswyl, Jean-Luc
    Brechtel, Klaus
    Speck, Ulrich
    Zeller, Thomas
    JOURNAL OF ENDOVASCULAR THERAPY, 2020, 27 (02) : 276 - 286
  • [2] Paclitaxel-coated versus uncoated balloon angioplasty for femoropopliteal artery in-stent restenosis
    Wu, Ridong
    Li, Zilun
    Wang, Mian
    Chang, Guangqi
    Yao, Chen
    Wang, Shenming
    INTERNATIONAL JOURNAL OF SURGERY, 2017, 42 : 72 - 82
  • [3] Paclitaxel-coated balloon catheter versus paclitaxel-coated stent for the treatment of coronary in-stent restenosis: the three-year results of the PEPCAD II ISR study
    Unverdorben, Martin
    Vallbracht, Christian
    Cremers, Bodo
    Heuer, Hubertus
    Hengstenberg, Christian
    Maikowski, Christian
    Werner, Gerald S.
    Antoni, Diethmar
    Kleber, Franz X.
    Bocksch, Wolfgang
    Leschke, Matthias
    Ackermann, Hanns
    Boxberger, Michael
    Speck, Ulrich
    Degenhardt, Ralf
    Scheller, Bruno
    EUROINTERVENTION, 2015, 11 (08) : 926 - 934
  • [4] Two year follow-up after treatment of coronary in-stent restenosis with a paclitaxel-coated balloon catheter
    Bruno Scheller
    Christoph Hehrlein
    Wolfgang Bocksch
    Wolfgang Rutsch
    Dariush Haghi
    Ulrich Dietz
    Michael Böhm
    Ulrich Speck
    Clinical Research in Cardiology, 2008, 97 : 773 - 781
  • [5] Two year follow-up after treatment of coronary in-stent restenosis with a paclitaxel-coated balloon catheter
    Scheller, Bruno
    Hehrlein, Christoph
    Bocksch, Wolfgang
    Rutsch, Wolfgang
    Haghi, Dariush
    Dietz, Ulrich
    Boehm, Michael
    Speck, Ulrich
    CLINICAL RESEARCH IN CARDIOLOGY, 2008, 97 (10) : 773 - 781
  • [6] Drug-coated balloon in superficial femoral artery in-stent restenosis
    Gerardi, Donato
    Alfani, Arturo
    Tesorio, Tullio
    Cioppa, Angelo
    Esposito, Giovanni
    Stabile, Eugenio
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2018, 14 (01): : 9 - 14
  • [7] Paclitaxel-Eluting Balloon vs Standard Angioplasty to Reduce Restenosis in Diabetic Patients With In-Stent Restenosis of the Superficial Femoral and Proximal Popliteal Arteries: Three-Year Results of the DEBATE-ISR Study
    Grotti, Simone
    Liistro, Francesco
    Angioli, Paolo
    Ducci, Kenneth
    Falsini, Giovanni
    Porto, Italo
    Ricci, Lucia
    Ventoruzzo, Giorgio
    Turini, Filippo
    Bellandi, Guido
    Bolognese, Leonardo
    JOURNAL OF ENDOVASCULAR THERAPY, 2016, 23 (01) : 52 - 57
  • [8] Drug-Eluting Balloons for the Treatment of the Superficial Femoral Artery In-Stent Restenosis 2-Year Follow-Up
    Virga, Vittorio
    Stabile, Eugenio
    Biamino, Giancarlo
    Salemme, Luigi
    Cioppa, Angelo
    Giugliano, Giuseppe
    Tesorio, Tullio
    Cota, Linda
    Popusoi, Grigore
    Pucciarelli, Armando
    Esposito, Giovanni
    Trimarco, Bruno
    Rubino, Paolo
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (04) : 411 - 415
  • [9] Paclitaxel-Eluting Balloon Versus Standard Balloon Angioplasty in In-Stent Restenosis of the Superficial Femoral and Proximal Popliteal Artery 1-Year Results of the PACUBA Trial
    Kinstner, Christian M.
    Lammer, Johannes
    Willfort-Ehringer, Andrea
    Matzek, Wolfgang
    Gschwandtner, Michael
    Javor, Domagoj
    Funovics, Martin
    Schoder, Maria
    Koppensteiner, Renate
    Loewe, Christian
    Ristl, Robin
    Wolf, Florian
    JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (13) : 1386 - 1392
  • [10] Feasibility and Safety of Paclitaxel-Coated Balloon Angioplasty for the Treatment of Intracranial Symptomatic In-Stent Restenosis
    Xu, Haowen
    Fu, Xiaojie
    Yuan, Yongjie
    Quan, Tao
    Wang, Zibo
    Han, Kaihao
    Liu, Guo
    Guan, Sheng
    FRONTIERS IN NEUROLOGY, 2020, 11