A "Step-Ramp-Step" Protocol to Identify Running Speed and Power Associated with the Maximal Metabolic Steady State

被引:9
|
作者
Van Rassel, Cody R. [1 ]
Ajayi, Oluwatimilehin O. [1 ]
Sales, Kate M. [1 ]
Azevedo, Rafael A. [1 ]
Murias, Juan M. [1 ]
Macinnis, Martin J. [1 ,2 ]
机构
[1] Univ Calgary, Fac Kinesiol, Calgary, AB, Canada
[2] Fac Kinesiol, KNB 2230,2500 Univ Dr NW, Calgary, AB T2N1N4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
EXERCISE INTENSITY; RUNNING POWER; STRYD; INCREMENTAL EXERCISE TEST; EXERCISE THRESHOLDS; CRITICAL INTENSITY; OXYGEN-UPTAKE; HEART-RATE; THRESHOLD; EXERCISE; WALKING; COST; OUTPUT; ELITE;
D O I
10.1249/MSS.0000000000003066
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
PurposeA previously established Step-Ramp-Step (SRS) exercise protocol was able to accurately predict the work rate associated with the maximal metabolic steady state (MMSS) in cyclists. The purpose of this study was to determine whether a modified SRS protocol could predict the running speed and power associated with the MMSS.MethodsFifteen (8 male; 7 female) runners (V?O-2max 54.5 [6.5] mL center dot kg(-1)center dot min(-1)) were recruited for this investigation composed of four to five visits. In the first visit, runners performed a moderate intensity step (MOD), an incremental exercise test, and a heavy intensity step (HVY), on a motorized treadmill. This SRS protocol was used to predict the running speed and power associated with the MMSS (i.e., the SRS-MMSS), where running power was assessed by a wearable device (Stryd) attached to each runner's shoe. Subsequent visits were used to confirm the maximal lactate steady state (MLSS) as a proxy measure of the MMSS (i.e., the MLSS-MMSS) and to validate the SRS-MMSS speed and power estimates.ResultsThe estimated SRS-MMSS running speed (7.2 [0.6] mph) was significantly lower than confirmed running speed at MLSS-MMSS (7.5 [0.8] mph; bias = 3.6%, P = 0.005); however, the estimated SRS-MMSS running power (241 [35] W) was not different than the MLSS-MMSS confirmed running power (240 [37] W; bias = -0.6%; P = 0.435). V?O-2 at SRS-MMSS (3.22 [0.49] L center dot min(-1)) was not different than respiratory compensation point (3.26 [0.58] L center dot min(-1); P = 0.430). Similarly, V?O-2 at MLSS-MMSS (3.30 [0.54] L center dot min(-1)) was not different than respiratory compensation point (P = 0.438).ConclusionsThe SRS protocol allows MMSS, as measured by MLSS, to be accurately determined using running power (Stryd), but not speed, in a single laboratory visit.
引用
收藏
页码:534 / 547
页数:14
相关论文
共 16 条
  • [1] A "Step-Ramp-Step" Protocol to Identify the Maximal Metabolic Steady State
    Iannetta, Danilo
    Inglis, Erin Calaine
    Pogliaghi, Silvia
    Murias, Juan M.
    Keir, Daniel A.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2020, 52 (09) : 2011 - 2019
  • [2] A modified step-ramp-step protocol to prescribe constant-speed exercise in treadmill running
    Faricier, Robin
    Micheli, Lorenzo
    Guluzade, Nasimi A.
    Murias, Juan M.
    Keir, Daniel A.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2024, 124 (11) : 3445 - 3455
  • [3] Is the critical running speed related to the intermittent maximal lactate steady state?
    de Lucas, Ricardo D.
    Dittrich, Naiandra
    Junior, Rubens B.
    de Souza, Kristopher M.
    Guglielmo, Luiz Guilherme A.
    JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2012, 11 (01) : 89 - 94
  • [4] Kinematics of Maximal Speed Sprinting With Different Running Speed, Leg Length, and Step Characteristics
    Miyashiro, Kenji
    Nagahara, Ryu
    Yamamoto, Kohei
    Nishijima, Takahiko
    FRONTIERS IN SPORTS AND ACTIVE LIVING, 2019, 1
  • [5] Can measures of critical power precisely estimate the maximal metabolic steady-state?
    Maturana, Felipe Mattioni
    Keir, Daniel A.
    McLay, Kaitlin M.
    Murias, Juan M.
    APPLIED PHYSIOLOGY NUTRITION AND METABOLISM, 2016, 41 (11) : 1197 - 1203
  • [6] Effects of step duration in incremental ramp protocols on peak power and maximal oxygen consumption
    Adami, Alessandra
    Sivieri, Andrea
    Moia, Christian
    Perini, Renza
    Ferretti, Guido
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2013, 113 (10) : 2647 - 2653
  • [7] Discussion of "Can measures of critical power precisely estimate the maximal metabolic steady-state?" - Is it still necessary to compare critical power to maximal lactate steady state?
    de Lucas, Ricardo Dantas
    APPLIED PHYSIOLOGY NUTRITION AND METABOLISM, 2018, 43 (01) : 94 - 95
  • [8] Functional threshold power is not a valid marker of the maximal metabolic steady state
    Wong, Stephen
    Burnley, Mark
    Mauger, Alexis
    Fenghua, Sun
    Hopker, James
    JOURNAL OF SPORTS SCIENCES, 2022, 40 (23) : 2578 - 2584
  • [9] Is Running Power a Useful Metric? Quantifying Training Intensity and Aerobic Fitness Using Stryd Running Power Near the Maximal Lactate Steady State
    van Rassel, Cody R.
    Ajayi, Oluwatimilehin O.
    Sales, Kate M.
    Griffiths, James K.
    Fletcher, Jared R.
    Edwards, W. Brent
    MacInnis, Martin J.
    SENSORS, 2023, 23 (21)
  • [10] Can an Incremental Step Test Be Used for Maximal Lactate Steady State Determination in Swimming? Clues for Practice
    Espada, Mario C.
    Alves, Francisco B.
    Curto, Dalia
    Ferreira, Catia C.
    Santos, Fernando J.
    Pessoa-Filho, Dalton M.
    Reis, Joana F.