A biomarker panel of secondary hypertension is simultaneously quantified by coupling of magnetic solid-phase extraction and liquid chromatography-tandem mass spectrometry

被引:1
作者
Gao, Xi [1 ,2 ]
Li, Xiaoyong [3 ]
Chen, Lingyun [2 ]
Chen, Shuyan [1 ,4 ]
Hou, Guixue [2 ]
Lin, Liang [2 ]
Wang, Qunjie [5 ,7 ]
Qu, Jiuxin [3 ,8 ]
Liu, Siqi [1 ,2 ,6 ]
机构
[1] Univ Chinese Acad Sci, Coll Life Sci, Beijing, Peoples R China
[2] BGI Genom, Shenzhen, Peoples R China
[3] Southern Univ Sci & Technol, Shenzhen Peoples Hosp 3, Affiliated Hosp 2, Dept Clin Lab,Natl Clin Res Ctr Infect Dis, Shenzhen, Peoples R China
[4] Southern Univ Sci & Technol, Shenzhen Peoples Hosp 3, Affiliated Hosp 2, Natl Clin Res Ctr Infect Dis, Shenzhen, Peoples R China
[5] Biosepur, Suzhou, Peoples R China
[6] Univ Chinese Acad Sci, Coll Life Sci, Beijing 100049, Peoples R China
[7] Biosepur, Suzhou 215123, Peoples R China
[8] Southern Univ Sci & Technol, Shenzhen Peoples Hosp 3, Affiliated Hosp 2, Natl Clin Res Ctr Infect Dis,Dept Clin Lab, Shenzhen 518114, Peoples R China
关键词
RADIOIMMUNOASSAY; ALDOSTERONE; DIAGNOSIS;
D O I
10.1002/rcm.9703
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RationaleSecondary hypertension is often caused by activation of complex multi-organ endocrine systems, while renin activity indicated by angiotensins (Angs), aldosterone (ALD) and cortisol (COR) in such systems are generally accepted as its diagnostic markers. As antibody-based methods cannot offer comparable quantification for these biomarkers, a liquid chromatography (LC)-tandem mass spectrometry (MS/MS)-based approach was developed to quantify them simultaneously and accurately.MethodsFive different beads for magnetic solid-phase extraction (MSPE) were evaluated towards their enrichment efficiency for these biomarkers. An LC system with optimized elution gradient and a triple-quadrupole MS with tuned parameters were coupled to quantitatively monitor the extracted analytes. The method performance was further examined such as linearity, precision, stability, recovery rate and matrix effect. Based on the developed method, the abundance of Ang II, ALD and COR in plasma was measured and the quantification was compared with that derived from commercial ELISA kits.ResultsAs compared with other MSPEs, Angs, ALD and COR were highly enriched by the HLB magnetic beads with satisfactory recoveries. These analytes were simultaneously quantified by LC/MS/MS and all the method parameters for quantification were well matched with the requirements of clinical testing. Comparison of the quantitative results derived from ELISA and LC/MS/MS exhibited that the two methods offered basically comparable values with Pearson r values at 0.896, 0.895 and 0.835, respectively. The stability test for plasma Angs at room temperature indicated that the abundance of Ang II was relatively stable within 3 h, whereas that of Ang I and Ang 1-7 was time-dependently changed.ConclusionsCoupling of HLB beads and LC/MS/MS thus enables simultaneous quantification of a set of biomarkers related to secondary hypertension.
引用
收藏
页数:11
相关论文
共 33 条
  • [11] Stability of direct renin concentration and plasma renin activity in EDTA whole blood and plasma at ambient and refrigerated temperatures from 0 to 72 hours
    Hepburn, Sophie
    Munday, Coral
    Taylor, Kevin
    Halsall, David J.
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2022, 60 (09) : 1384 - 1392
  • [12] Poor Performance of Angiotensin II Enzyme-Linked Immuno-Sorbent Assays in Mostly Hypertensive Cohort Routinely Screened for Primary Aldosteronism
    Lebek-Szatanska, Agnieszka
    Papierska, Lucyna
    Glinicki, Piotr
    Zgliczynski, Wojciech
    [J]. DIAGNOSTICS, 2022, 12 (05)
  • [13] Simultaneous Determination of Cortisol and Cortisone from Human Serum by Liquid Chromatography-Tandem Mass Spectrometry
    Lee, Sanghoo
    Lim, Hwan-Sub
    Shin, Hye-Jin
    Kim, Seol-A
    Park, Jimyeong
    Kim, Hyun-Chul
    Kim, Hyogyeong
    Kim, Hyung Joo
    Kim, Yun-Tae
    Lee, Kyoung-Ryul
    Kim, Young-Jin
    [J]. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2014, 2014
  • [14] The relationship of plasma renin, angiotensin, and aldosterone levels to blood pressure variability and target organ damage in children with essential hypertension
    Liu, Yang
    Lin, Yao
    Zhang, Ming-Ming
    Li, Xiao-Hui
    Liu, Yan-Yan
    Zhao, Jing
    Shi, Lin
    [J]. BMC CARDIOVASCULAR DISORDERS, 2020, 20 (01)
  • [15] Quantitation of plasma angiotensin II in healthy Chinese subjects by a validated liquid chromatography tandem mass spectrometry method
    Lo, Clara Wai-Shan
    Tsui, Teresa Kam-Chi
    Ma, Ronald Ching-Wan
    Chan, Michael Ho-Ming
    Ho, Chung-Shun
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (05)
  • [16] LUN S, 1983, CLIN CHEM, V29, P268
  • [17] MENARD J, 1985, J HYPERTENS, V3, pS275
  • [18] Analysis of urinary organic acids by gas chromatography tandem mass spectrometry method for metabolic profiling applications
    Mouskeftara, T.
    Virgiliou, C.
    Theodoridis, G.
    Gika, H.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2021, 1658
  • [19] Analysis of Immunobiochemical Parameters in Overweight People in Assessing the Risk of Cardiovascular Diseases
    Myagkova, M. A.
    Orlova, E. A.
    Petrochenko, S. N.
    Bobrova, Z. V.
    Bachurin, S. O.
    [J]. BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2023, 174 (04) : 446 - 450
  • [20] Intrarenal angiotensin II and its contribution to the genesis of chronic hypertension
    Navar, L. Gabriel
    Prieto, Minolfa C.
    Satou, Ryousuke
    Kobori, Hiroyuki
    [J]. CURRENT OPINION IN PHARMACOLOGY, 2011, 11 (02) : 180 - 186