A biomarker panel of secondary hypertension is simultaneously quantified by coupling of magnetic solid-phase extraction and liquid chromatography-tandem mass spectrometry

被引:1
作者
Gao, Xi [1 ,2 ]
Li, Xiaoyong [3 ]
Chen, Lingyun [2 ]
Chen, Shuyan [1 ,4 ]
Hou, Guixue [2 ]
Lin, Liang [2 ]
Wang, Qunjie [5 ,7 ]
Qu, Jiuxin [3 ,8 ]
Liu, Siqi [1 ,2 ,6 ]
机构
[1] Univ Chinese Acad Sci, Coll Life Sci, Beijing, Peoples R China
[2] BGI Genom, Shenzhen, Peoples R China
[3] Southern Univ Sci & Technol, Shenzhen Peoples Hosp 3, Affiliated Hosp 2, Dept Clin Lab,Natl Clin Res Ctr Infect Dis, Shenzhen, Peoples R China
[4] Southern Univ Sci & Technol, Shenzhen Peoples Hosp 3, Affiliated Hosp 2, Natl Clin Res Ctr Infect Dis, Shenzhen, Peoples R China
[5] Biosepur, Suzhou, Peoples R China
[6] Univ Chinese Acad Sci, Coll Life Sci, Beijing 100049, Peoples R China
[7] Biosepur, Suzhou 215123, Peoples R China
[8] Southern Univ Sci & Technol, Shenzhen Peoples Hosp 3, Affiliated Hosp 2, Natl Clin Res Ctr Infect Dis,Dept Clin Lab, Shenzhen 518114, Peoples R China
关键词
RADIOIMMUNOASSAY; ALDOSTERONE; DIAGNOSIS;
D O I
10.1002/rcm.9703
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RationaleSecondary hypertension is often caused by activation of complex multi-organ endocrine systems, while renin activity indicated by angiotensins (Angs), aldosterone (ALD) and cortisol (COR) in such systems are generally accepted as its diagnostic markers. As antibody-based methods cannot offer comparable quantification for these biomarkers, a liquid chromatography (LC)-tandem mass spectrometry (MS/MS)-based approach was developed to quantify them simultaneously and accurately.MethodsFive different beads for magnetic solid-phase extraction (MSPE) were evaluated towards their enrichment efficiency for these biomarkers. An LC system with optimized elution gradient and a triple-quadrupole MS with tuned parameters were coupled to quantitatively monitor the extracted analytes. The method performance was further examined such as linearity, precision, stability, recovery rate and matrix effect. Based on the developed method, the abundance of Ang II, ALD and COR in plasma was measured and the quantification was compared with that derived from commercial ELISA kits.ResultsAs compared with other MSPEs, Angs, ALD and COR were highly enriched by the HLB magnetic beads with satisfactory recoveries. These analytes were simultaneously quantified by LC/MS/MS and all the method parameters for quantification were well matched with the requirements of clinical testing. Comparison of the quantitative results derived from ELISA and LC/MS/MS exhibited that the two methods offered basically comparable values with Pearson r values at 0.896, 0.895 and 0.835, respectively. The stability test for plasma Angs at room temperature indicated that the abundance of Ang II was relatively stable within 3 h, whereas that of Ang I and Ang 1-7 was time-dependently changed.ConclusionsCoupling of HLB beads and LC/MS/MS thus enables simultaneous quantification of a set of biomarkers related to secondary hypertension.
引用
收藏
页数:11
相关论文
共 33 条
  • [1] Magnetic multi-walled carbon nanotube poly(styrene-co-divinylbenzene) for propranolol extraction and separation by capillary electrophoresis
    Adelantado, Carlos
    Murtada, Khaled
    Rios, Angel
    Zougagh, Mohammed
    [J]. BIOANALYSIS, 2018, 10 (15) : 1193 - 1205
  • [2] Estimation of angiotensin peptides in biological samples by LC-MS method
    Ali, Quaisar
    Wu, Yonnie
    Nag, Sourashish
    Hussain, Tahir
    [J]. ANALYTICAL METHODS, 2014, 6 (01) : 215 - 222
  • [3] Angiotensin I and angiotensin II concentrations and their ratio in catecholamine-resistant vasodilatory shock
    Bellomo, Rinaldo
    Wunderink, Richard G.
    Szerlip, Harold
    English, Shane W.
    Busse, Laurence W.
    Deane, Adam M.
    Khanna, Ashish K.
    McCurdy, Michael T.
    Ostermann, Marlies
    Young, Paul J.
    Handisides, Damian R.
    Chawla, Lakhmir S.
    Tidmarsh, George F.
    Albertson, Timothy E.
    [J]. CRITICAL CARE, 2020, 24 (01):
  • [4] An LC-MS/MS assay for analysis of equilibrium angiotensin II in human serum
    Bernstone, Laura
    Adaway, Joanne E.
    Keevil, Brian G.
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 2021, 58 (05) : 422 - 433
  • [5] A liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based assay for simultaneous quantification of aldosterone, renin activity, and angiotensin II in human plasma
    Chen, Fangjun
    Cheng, Ziyun
    Peng, Yingfei
    Wang, Zhenxin
    Huang, Chao
    Liu, Dan
    Wang, Beili
    Pan, Baishen
    Guo, Wei
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1179
  • [6] The renin-angiotensin-aldosterone system and its therapeutic targets
    Colafella, Katrina M. Mirabito
    Bovee, Dominique M.
    Danser, A. H. Jan
    [J]. EXPERIMENTAL EYE RESEARCH, 2019, 186
  • [7] SPECIFIC, NON-CHROMATOGRAPHIC RADIOIMMUNOASSAY FOR HUMAN PLASMA CORTISOL
    DASH, RJ
    ENGLAND, BG
    MIDGLEY, AR
    NISWENDER, GD
    [J]. STEROIDS, 1975, 26 (05) : 647 - 661
  • [8] Plasma Steroid Metabolome Profiling for Diagnosis and Subtyping Patients with Cushing Syndrome
    Eisenhofer, Graeme
    Masjkur, Jimmy
    Peitzsch, Mirko
    Di Dalmazi, Guido
    Bidlingmaier, Martin
    Grueber, Matthias
    Fazel, Julia
    Osswald, Andrea
    Beuschlein, Felix
    Reincke, Martin
    [J]. CLINICAL CHEMISTRY, 2018, 64 (03) : 586 - 596
  • [9] Fountain JH., 2023, Physiology, renin angiotensin system
  • [10] Effect of sample delivery conditions on Renin-Angiotensin-Aldosterone System (RAAS) assay
    Fu, Yu
    Ge, Shibin
    Qiu, Xueting
    Cui, Rongrong
    Zhang, Chen
    Xu, Xindan
    Li, Jianhua
    Feng, Jianlin
    Bai, Jianling
    Sun, Min
    Liu, Wei
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2020, 80 (04) : 336 - 342