Concentric and eccentric compressive behaviors of stiffened T-shaped CFST columns

被引:7
|
作者
Zheng, Yongqian [1 ]
Lin, Yihao [1 ]
Liang, Wanggeng [1 ,2 ]
机构
[1] Fujian Univ Technol, Fujian Prov Key Lab Adv Technol & Informatizat Civ, Coll Civil Engn, Fuzhou 350118, Fujian, Peoples R China
[2] Xian Univ Architecture & Technol, Sch Civil Engn, Xian 710055, Peoples R China
基金
中国国家自然科学基金;
关键词
Stiffened columns; T-shaped CFST; Concentric compression; Eccentric compression; Loading angles; Ultimate strength; STEEL TUBULAR COLUMNS; STUB COLUMNS; PERFORMANCE; TUBES;
D O I
10.1016/j.jcsr.2023.108229
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Longitudinal stiffeners can improve the mechanical performance of T-shaped concrete-filled steel tubular (CFST) columns. In practical applications, stiffened T-shaped CFST is often subjected to bidirectional loading, but there has been few studies on its concentric and eccentric compressive performance considering different loading angles in the past. Therefore, six stiffened T-shaped CFST columns were tested in this paper and the main pa-rameters were loading angle (45 degrees and 135 degrees), load eccentricity (0, 0.25 and 0.5), and slenderness ratio (31.5 and 41.9). Finite element (FE) models of stiffened T-shaped CFST columns under different loading angles were established, and the practical design methods for concentrically and eccentrically loaded columns were obtained on the basis of parametric analysis. The results show that the ultimate strength of stiffened T-shaped CFST column at 135 degrees is greater than that at 45 degrees with a difference of 12.6%. Setting longitudinal stiffeners can increase the ultimate strength by 13.2%-24.5%, and the enhancement extent declines with increasing load eccentricity. The maximum deviation of loading angles on stability coefficient under different slenderness ratios can reach 33.9%, while the corresponding deviation on relative moment (M/Mu) under different relative axial load (N/Nu) can reach 63.4%. The design method of stability coefficient for multi-cell T-shaped CFST is also available for concentrically loaded stiffened columns. Considering the loading angle transformation, the proposed interaction curve formulas can be used for the design of eccentrically loaded stiffened T-shaped CFST columns with good accuracy.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Static behavior of T-shaped concrete-filled steel tubular columns subjected to concentric and eccentric compressive loads
    Yang, Yuanlong
    Wang, Yuyin
    Fu, Feng
    Liu, Jingchen
    THIN-WALLED STRUCTURES, 2015, 95 : 374 - 388
  • [2] Experimental study of stiffened L-shaped CFST columns under eccentric compressive loads with different loading angles
    Zheng, Yongqian
    Zeng, Shaoxi
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2021, 42 : 264 - 270
  • [3] Behavior of innovative T-shaped multi-partition steel-concrete composite columns under concentric and eccentric compressive loadings
    Chen, J.
    Zhang, S. M.
    Huang, Z. F.
    Zhang, X. X.
    Guo, L. H.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018), 2018, : 289 - 296
  • [4] Performance of T-shaped CFST columns with embedded T-shaped steel skeleton under axial compression
    Zheng, Zezhong
    Zhang, Jicheng
    Miao, Yuan
    Zhou, Bowen
    Huang, Wenjie
    He, Yuzhou
    Lu, Qichao
    Wang, Yifan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 215
  • [5] Global Stability Performance of Multi-Cellular T-Shaped CFST Slender Columns under Eccentric Compression
    Zhang, Lei
    Zhang, Yu-Jia
    Tong, Jing-Zhong
    Tong, Gen-Shu
    Yu, Chao-Qun
    Xu, Yi-Min
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2023, 23 (02)
  • [6] Behavior of stiffened and multi-cell L-shaped CFST columns under eccentric compression
    Zheng, Yongqian
    Liang, Wanggeng
    Ma, Shuangshuang
    Zeng, Shaoxi
    THIN-WALLED STRUCTURES, 2022, 174
  • [7] SHEAR CAPACITY OF T-SHAPED DIAPHRAGM-THROUGH JOINTS OF CFST COLUMNS
    Rong, Bin
    Liu, Rui
    Zhang, Ruoyu
    Liu, Shuai
    Fafitis, Apostolos
    JOURNAL OF MECHANICS OF MATERIALS AND STRUCTURES, 2017, 12 (04) : 373 - 390
  • [8] Static behavior of T-shaped concrete-filled steel tubular columns subjected to eccentric compressive loads
    Yang, H.
    Zhang, S. M.
    Yang, Y. L.
    TUBULAR STRUCTURES XIV, 2012, : 59 - 64
  • [9] Axial compressive behavior of stiffened and multi-cell cross-shaped CFST stub columns
    Zheng, Yongqian
    Lin, Yihao
    Ma, Shuangshuang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 213
  • [10] Performance of T-shaped CFST stub columns with binding bars under axial compression
    Zuo, Zhi-Liang
    Cai, Jian
    Chen, Qing-Jun
    Liu, Xin-Pei
    Yang, Chun
    Mo, Ting-Wei
    THIN-WALLED STRUCTURES, 2018, 129 : 183 - 196