Lateral load response of L-shaped steel-concrete composite shear walls using multi-partition steel tube

被引:7
|
作者
Wang, Yunhe [1 ,2 ]
Guo, Lanhui [2 ,5 ]
Li, Hongda [2 ]
Shafaei, Soheil [3 ]
Yu, Yue [4 ]
机构
[1] Taiyuan Univ Technol, Sch Civil Engn, Taiyuan 030024, Peoples R China
[2] Harbin Inst Technol, Minist Educ, Key Lab Struct Dynam Behav & Control, Harbin 150090, Peoples R China
[3] Purdue Univ, Lyles Sch Civil Engn, W Lafayette, IN 47906 USA
[4] China Nucl Power Engn Co Ltd, Beijing, Peoples R China
[5] Harbin Inst Technol, Sch Civil Engn, Harbin 150090, Peoples R China
基金
中国国家自然科学基金;
关键词
L-shaped composite shear wall; Multi-partition steel tube; Seismic response; Experimental study; Finite element modeling; SEISMIC BEHAVIOR; FINITE-ELEMENT; STUB COLUMNS; STRENGTH;
D O I
10.1016/j.engstruct.2023.116671
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Behavior of L-shaped multi-partition steel-concrete composite shear walls (MP-SC-CSWs) subjected to the cyclic lateral load is experimentally and numerically evaluated. Such composite shear walls possess proper capacity, stiffness, and ductility, as the steel tube strengthened by inner steel plates considerably confines the infill concrete. Four large-scale L-shaped MP-SC-CSW specimens were designed, fabricated, and tested. The L-shaped specimens were exposed to lateral hysteretic loading and axial compression loading. The experimental parameters were axial load ratios and height-to-depth ratios (wall aspect ratios). The experimental results indicated that the L-shaped MP-SC-CSWs had high lateral capacities, energy dissipations, and good ductility. Based on the experimental observations, specimens failed in flexure mode. Increasing the axial load ratio enhances the capacity to dissipate energy but decreases the ductility. The tested specimens could meet the drift requirement of the specification even when subjected to a high design axial load ratio of 0.76. Additionally, the wall aspect ratios had little influence on the ductility. 3D nonlinear finite element models of tested specimens were established and verified with test results to conduct further numerical studies. A simplified method based on the plastic stress distribution was developed and confirmed by the experimental and finite element analysis to calculate the flexural capacities of MP-SC-CSWs.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Cyclic behavior of low shear-span ratio dovetailed profiled steel-concrete composite shear walls
    Huang, Zhenfeng
    Zhang, Sumei
    Guo, Lanhui
    JOURNAL OF BUILDING ENGINEERING, 2022, 59
  • [32] Shear performance of C-shaped perforated angle connectors in steel-concrete composite beams
    Sakhri, Nafissa
    Ihaddoudene, Abd-Nacer Touati
    Saidani, Messaoud
    Da Costa-Neves, Luis Filipe
    STRUCTURES, 2025, 74
  • [33] Experimental study of lateral load behavior of H-shaped precast reinforced concrete shear walls with bolted steel connections
    Sun, Jian
    Qiu, Hongxing
    Lu, Yong
    Jiang, Hongbo
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2019, 28 (15)
  • [34] Monotonic behavior of C and L shaped angle shear connectors within steel-concrete composite beams: an experimental investigation
    Shariati, Mandi
    Tahmasbi, Farzad
    Mehrabi, Peyman
    Bahadori, Alireza
    Toghroli, Ali
    STEEL AND COMPOSITE STRUCTURES, 2020, 35 (02) : 237 - 247
  • [35] Shear Behavior of U-Shaped Steel-Concrete Composite Beams with Positive and Negative Loading
    Zhao, Yukun
    Li, Zhenbao
    Ma, Hua
    Kan, Jiping
    Zhang, Nana
    INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2022, 20 (10) : 1229 - 1246
  • [36] EXPERIMENTAL RESEARCH ON CONCRETE-ENCASED COMPOSITE COLUMNS WITH L-SHAPED STEEL SECTIONS
    Xiao, Yunfeng
    Zhou, Zhengtao
    Chen, Yiguang
    Jin, SiQian
    Zeng, Lei
    FUNDAMENTAL RESEARCH IN STRUCTURAL ENGINEERING: RETROSPECTIVE AND PROSPECTIVE, VOLS 1 AND 2, 2016, : 1224 - 1232
  • [37] Study on Seismic Performance and Application of L-shaped Concrete-filled Steel Tube Column
    Jiang, Shiqi
    PROCEEDINGS OF THE 2024 3RD INTERNATIONAL CONFERENCE ON STRUCTURAL SEISMIC RESISTANCE, MONITORING AND DETECTION, SSRMD 2024, 2024, 27 : 93 - 104
  • [38] Experimental and numerical analysis of L-shaped concrete-filled steel tube stub columns
    Wu, Lili
    Han, Ganghao
    Di Sarno, Luigi
    Chen, Xi
    Sun, Yao
    STRUCTURES, 2024, 69
  • [39] Effects of Openings and Axial Load Ratio on the Lateral Capacity of Steel-Fiber-Reinforced Concrete Shear Walls
    Lin, Zhou
    Zhang, Hongmei
    Monti, Giorgio
    Castoro, Chiara
    BUILDINGS, 2022, 12 (11)
  • [40] Modelling of Cyclic Load Behaviour of Smart Composite Steel-Concrete Shear Wall Using Finite Element Analysis
    Najm, Hadee Mohammed
    Ibrahim, Amer M.
    Sabri, Mohanad Muayad
    Hassan, Amer
    Morkhade, Samadhan
    Mashaan, Nuha S.
    Eldirderi, Moutaz Mustafa A.
    Khedher, Khaled Mohamed
    BUILDINGS, 2022, 12 (06)