Local and post-local buckling behavior of welded square high-strength steel tubes with concrete-infilled restraints

被引:12
|
作者
Sun, Lipeng [1 ]
Liu, Yongjian [1 ,2 ]
Wang, Haitao [1 ]
Shi, Fengrong [1 ]
机构
[1] Changan Univ, Sch Highway, Xian 710064, Peoples R China
[2] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
基金
中国国家自然科学基金;
关键词
Concrete-filled; High-strength steel; Local buckling; Post-buckling; Slenderness; Effective width; Unilateral restraint; RESIDUAL-STRESS; SLENDERNESS LIMITS; BOX SECTIONS; STUB COLUMNS; TESTS;
D O I
10.1016/j.tws.2022.110381
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Concrete-filled high-strength steel tubular members gain increasing popularity as the building height and bridge span increase. The slender sections and higher stress levels, however, make the high-strength steel plates more susceptible to local buckling. This paper reports an experimental and numerical investigation on local and post-local buckling behavior of welded square high-strength steel tubes with concrete-infilled restraints. Sixteen high-strength steel tubes with nominal yield strengths of 460, 500, and 550 MPa with concrete-infilled restraints were tested. The experimental results reveal that the post-buckling reserve strength of steel tubes with slender sections increases with the increase in plate slenderness regardless of steel grade. A total of 168 numerical models were subsequently established using the verified finite element method. Based on the finite element analysis results, the slenderness limits and effective width formula were proposed for both high-strength and normal-strength steel tubes with concrete-infilled restraints. Available test data of steel-only-loaded concrete-filled steel tubular specimens constitutes an experimental database to evaluate the reliability of the existing slenderness limits and effective width formulas. The comparison result shows that GB 50936, AS/NZS 2327, and AISC 360-16 overestimate the slenderness limits, while Song et al. underestimate the slenderness limit excessively. The proposed slenderness limit (lambda(pl) = 0.500) is more consistent with the experimental results with a reasonable conservative level. The mean ratio of predicted post-buckling strengths by the proposed effective width formula to experimental results is 0.94, with a standard deviation of 0.073. The proposed slenderness limit and effective width formula provide a more accurate prediction and, therefore, are recommended in design.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] High strength steel square and rectangular tubular stub columns infilled with concrete
    Cai, Yancheng
    Su, Meini
    Chen, Xuerui
    Young, Ben
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 179
  • [42] Local-overall interactive buckling of high strength steel welded I-section columns under axial compression
    Huang, Bin
    Zhang, Wen Fu
    THIN-WALLED STRUCTURES, 2020, 157 (157)
  • [43] Experimental study on local buckling of high-strength Q960 steel columns at elevated temperatures
    Wang, Weiyong
    Li, Xiang
    Al-azzani, Hisham
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 183
  • [44] Experimental and Analytical Study on Local Buckling Behavior of the Concrete-filled Thin-walled Welded Steel Columns
    Martinavicius, Deividas
    Augonis, Mindaugas
    Tiago Arruda, Mario Rui
    PERIODICA POLYTECHNICA-CIVIL ENGINEERING, 2020, 64 (03): : 917 - 927
  • [45] Local-overall interactive buckling behaviour of 800 MPa high-strength steel welded H-section members under axial compression
    Cao, Xianlei
    Zhong, Rui
    Xu, Yong
    Cheng, Chao
    Liu, Shitong
    Chen, Zongping
    Kim, Seung-Eock
    Kong, Zhengyi
    THIN-WALLED STRUCTURES, 2021, 164
  • [46] Local buckling of 460 MPa high strength steel welded section stub columns under axial compression
    Shi, Gang
    Zhou, Wenjing
    Bai, Yu
    Lin, Cuocuo
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 100 : 60 - 70
  • [47] Design of concrete-filled high-strength steel RHS and SHS tubes under bending
    Deng, Yun-Qiao
    Huang, Yuner
    Young, Ben
    ENGINEERING STRUCTURES, 2024, 320
  • [48] AXIAL BEHAVIOR OF HIGH-STRENGTH CONCRETE-FILLEDHIGH-STRENGTH SQUARE STEEL TUBULAR STUB COLUMNS
    Li, Guo-Chang
    Chen, Bo-Wen
    Yang, Zhi-Jian
    Ge, Han-bin
    Li, Xiao
    ADVANCED STEEL CONSTRUCTION, 2021, 17 (02): : 158 - 168
  • [49] Axial compressive behavior of high-strength spiral-confined high-strength concrete-filled high-strength square steel-tube columns
    Yang, Zhijian
    Sun, Lisuo
    Liu, Mo
    Pan, Jianbang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2025, 226
  • [50] Experimental and numerical behavior of eccentrically loaded square concrete-filled steel tubular long columns made of high-strength steel and concrete
    Li, Guo-Chang
    Chen, Bo-Wen
    Yang, Zhi-Jian
    Liu, Yao-Peng
    Feng, Yi-He
    THIN-WALLED STRUCTURES, 2021, 159