Headspace solid-phase microextraction - gas chromatography - mass spectrometry qualitative screening method for active compounds, adulterants and impurities in ecstasy tablets seized in Northern Santa Catarina State, Brazil

被引:3
作者
Nicolodi, Caroline [1 ]
Slominski, William Henrique [1 ]
Parabocz, Gisele Chibinski [2 ]
Pericolo, Suellen [2 ]
Da-Col, Jose Augusto [1 ]
Martendal, Edmar [1 ]
机构
[1] Santa Catarina State Univ, Analyt Chem Inorgan Nanomat Res Lab, Chem Dept, Joinville, SC, Brazil
[2] Sci Police Joinville Reg Superintendency, Joinville, SC, Brazil
关键词
Ecstasy; SPME; Forensic illicit drug analysis; MDMA; MDMA; IDENTIFICATION; HYDROCHLORIDE; CHEMOMETRICS; PROFILES;
D O I
10.1016/j.forsciint.2024.111932
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
The present work describes the development of a headspace solid-phase microextraction (HS-SPME) followed by gas chromatography - mass spectrometry (GC-MS) method for the qualitative analysis of compounds in seized ecstasy tablets that can be easily implemented in regular laboratories. HS-SPME with a DVB/CAR/PDMS 50/30 mu m fiber was used to extract the ecstasy pills' components, including major and minor ones, in a single extraction/chromatographic run. For HS-SPME, the incubation time (0 min to 30 min), the extraction time (10 min to 40 min) and temperature (40 degrees C to 80 degrees C), the buffer volume (3 mL to 8 mL), the buffer pH (6 to 9) and the NaCl concentration (0 mol/L to 6 mol/L) were evaluated using fractional factorial design. Different split ratios and detector voltages were also evaluated. The optimal compromise between sensitivity and peak resolution was found to be incubation and extraction at 65 degrees C for 10 min and 25 min, respectively, 3 mL of pH 9 buffer containing 3 mol/L NaCl, using 40.0 mg of the powdered samples in a 15-mL amber glass vial, and an injection with a split ratio of 1:10 at 260 degrees C for 10 min. Under optimal conditions, 44 samples from different seizures were analyzed. Seventy-five compounds were tentatively identified by the proposed method, including active substances, medicines, caffeine, safrole derivatives, synthesis intermediates and solvent residues. The number of tentatively identified compounds per sample varied from 8 to 24, with a mean of 15. Important findings in ecstasy samples, such as norcinamolaurin, alpha-methyl-1,3-benzodioxole-5-propanamide, alpha-methyl-3,4-methylenedioxyphenylpropionitrile, acetylsalicylic acid, piperonylonitrile, methyl isobutyl ketone, mesitylene, and 4-[3-(dimethylamino)propyl]- 2,6-dimethylphenol, identified with a frequency higher than 10%, are not found in the literature so far. The method precision, based on relative standard deviation of peak areas, ranged from 5% to 15%, depending on the compound. The method was shown to be simple, relatively fast, precise and a powerful tool for the identification of major and minor components in ecstasy tablets in a single analytical cycle, being useful for screening or quantitative purposes, if authentic standards are available.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Screening for petrochemical contamination in seafood by headspace solid-phase microextraction gas chromatography-mass spectrometry
    Bencsath, F. Aladar
    Benner, Ronald A., Jr.
    Abraham, Ann
    Wang, Yuesong
    El Said, Kathleen R.
    Jester, Edward L. E.
    Plakas, Steven M.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (14) : 4079 - 4090
  • [2] Headspace Solid-Phase Microextraction Coupled with Gas Chromatography Mass Spectrometry for the Characterization of Polymeric Materials
    Kusch, Peter
    LC GC NORTH AMERICA, 2018, 36 (01) : 52 - 61
  • [3] Determination of carbonyl compounds in beer by derivatisation and headspace solid-phase microextraction in combination with gas chromatography and mass spectrometry
    Saison, Daan
    De Schutter, David P.
    Delvaux, Filip
    Delvaux, Freddy R.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (26) : 5061 - 5068
  • [4] Qualitative screening for volatile organic compounds in human blood using solid-phase microextraction and gas chromatography-mass spectrometry
    Gottzein, Anne Kathrin
    Musshoff, Frank
    Madea, Burkhard
    JOURNAL OF MASS SPECTROMETRY, 2010, 45 (04): : 391 - 397
  • [5] Determination of trichloroethylene in biological samples by headspace solid-phase microextraction gas chromatography/mass spectrometry
    Liu, Yongzhen
    Muralidhara, Srinivasa
    Bruckner, James V.
    Bartlett, Michael G.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 863 (01): : 26 - 35
  • [6] Determination of Lactones in Wines by Headspace Solid-Phase Microextraction and Gas Chromatography Coupled with Mass Spectrometry
    Perez-Olivero, S. J.
    Perez-Pont, M. L.
    Conde, J. E.
    Perez-Trujillo, J. P.
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2014, 2014
  • [7] Determination of phthalates and adipate in bottled water by headspace solid-phase microextraction and gas chromatography/mass spectrometry
    Cao, Xu-Liang
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1178 (1-2) : 231 - 238
  • [8] A New Method for the Determination of Carbonyl Compounds in Wines by Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Ion Trap Mass Spectrometry
    Perez Olivero, Sergio J.
    Perez Trujillo, Juan P.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2010, 58 (24) : 12976 - 12985
  • [9] An accurate quantitative method for the analysis of terpenes in milk fat by headspace solid-phase microextraction coupled to gas chromatography-mass spectrometry
    Abilleira, Eunate
    de Renobales, Mertxe
    Isabel Najera, Ana
    Virto, Mailo
    Ruiz de Gordoa, Juan Carlos
    Jose Perez-Elortondo, Francisco
    Albisu, Marta
    Barron, Luis Javier R.
    FOOD CHEMISTRY, 2010, 120 (04) : 1162 - 1169
  • [10] Rapid Analysis of 27 Volatile Sulfur Compounds in Wine by Headspace Solid-Phase Microextraction Gas Chromatography Tandem Mass Spectrometry
    Davide Slaghenaufi
    Loris Tonidandel
    Sergio Moser
    Tomás Román Villegas
    Roberto Larcher
    Food Analytical Methods, 2017, 10 : 3706 - 3715