Plan quality analysis of stereotactic ablative body radiotherapy treatment planning in liver tumor

被引:0
作者
Watcharawipha, Anirut [1 ,2 ]
Chakrabandhu, Somvilai [1 ,2 ,4 ]
Kongsa, Anupong [1 ]
Tippanya, Damrongsak [1 ]
Chitapanarux, Imjai [1 ,2 ,3 ]
机构
[1] Chiang Mai Univ, Fac Med, Dept Radiol, Div Radiat Oncol, Chiang Mai, Thailand
[2] Chiang Mai Univ, Fac Med, Northern Thai Res Grp Radiat Oncol NTRG RO, Chiang Mai, Thailand
[3] Chiang Mai Univ, Maharaj Nakorn Chiang Mai Hosp, Fac Med, Chiang Mai Canc Registry, Chiang Mai, Thailand
[4] Chiang Mai Univ, Dept Radiol, Div Radiat Oncol, Fac Med, 110 Intawaroros Rd, Mueang 50200, ChiangMai, Thailand
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2023年 / 24卷 / 07期
关键词
helical tomotherapy; liver tumor; stereotactic ablative body radiotherapy; volumetric-modulated arc therapy; MODULATED ARC THERAPY; HELICAL TOMOTHERAPY; HEPATOCELLULAR-CARCINOMA; RADIATION-THERAPY; CONFORMITY; INDEX; LUNG;
D O I
10.1002/acm2.13948
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeStereotactic ablative body radiotherapy (SABR) in the liver, RTOG-1112 guides the treatment modalities including the dose constraints for this technique but not the plan parameters. This study is not only analyzing the plan quality by utilizing the plan parameters and indexes but also compares treatment modalities from the protocol implementation. Method and materialTwenty-five patients treated in the period from February 2020 to September 2022 were recruited in this analysis. Two planners randomly selected the patients and modalities. The modalities employed were Volumetric-Modulated Arc Therapy (VMAT) and Helical Tomotherapy (HT). Various parameters and indexes were used to access not only the plan quality but also to compare each modality. The parameters and indexes studied were the homogeneity index (HI), conformity index (CI), gradient distance (GD), and the dose received by the organs at risk. ResultThe data reveals that the mean volume of PTV is 60.8 +/- 53.9 cc where these targets exhibit no significant difference between each modality. The HI shows a consistent value for both modalities. Between each modality, the CI value shows less deviation, but the HT shows slightly higher performance than VMAT. The value of GD is 1.5 +/- 0.3 cm where the HT provides a shorter distance compared to VMAT as well. ConclusionThe parameters and indexes should be utilized for the plan evaluation although in the guidelines this was not required. Various modalities were employed for treatment. Both can achieve the treatment criteria with slightly low performance of VMAT.
引用
收藏
页数:9
相关论文
共 24 条
  • [1] Stereotactic body radiotherapy for central lung tumors: Finding the balance between safety and efficacy in the "no fly" zone
    Ahmed, Nissar
    Hasan, Shaakir
    Schumacher, Lana
    Colonias, Athanasios
    Wegner, Rodney E.
    [J]. THORACIC CANCER, 2018, 9 (10) : 1211 - 1214
  • [2] [Anonymous], 2012, RTOG1112, V30, P1
  • [3] Helical IMRT-Based Stereotactic Body Radiation Therapy Using an Abdominal Compression Technique and Modified Fractionation Regimen for Small Hepatocellular Carcinoma
    Chen, Yi-Xing
    Zhuang, Yuan
    Yang, Ping
    Fan, Jia
    Zhou, Jian
    Hu, Yong
    Zhu, Wen-Chao
    Sun, Jing
    Zeng, Zhao-Chong
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2020, 19
  • [4] Choi Seo Hee, 2017, Journal of Liver Cancer, V17, P45
  • [5] Conformity index:: A review
    Feuvret, L
    Noël, G
    Mazeron, JJ
    Bey, P
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (02): : 333 - 342
  • [6] Stereotactic body radiation therapy in patients with hepatocellular carcinoma: A mini-review
    Gerum, Sabine
    Jensen, Alexandra D.
    Roeder, Falk
    [J]. WORLD JOURNAL OF GASTROINTESTINAL ONCOLOGY, 2019, 11 (05) : 367 - 376
  • [7] Liver segmentation: indications, techniques and future directions
    Gotra, Akshat
    Sivakumaran, Lojan
    Chartrand, Gabriel
    Kim-Nhien Vu
    Vandenbroucke-Menu, Franck
    Kauffmann, Claude
    Kadoury, Samuel
    Gallix, Benoit
    de Guise, Jacques A.
    Tang, An
    [J]. INSIGHTS INTO IMAGING, 2017, 8 (04): : 377 - 392
  • [8] Henry J, 2016, J RADIOSURGERY SBRT, V4, P145
  • [9] International Commission on Radiation Units and Measurements, 2010, ICRU Report 83 Prescribing, Recording, and Reporting Photon-beam Intensity-modulated Radiation Therapy (IMRT) -Journal of the ICRU - Vol 10 No 1 2010
  • [10] Homogeneity Index: An objective tool for assessment of conformal radiation treatments
    Kataria, Tejinder
    Sharma, Kuldeep
    Subramani, Vikraman
    Karrthick, K. P.
    Bisht, Shyam S.
    [J]. JOURNAL OF MEDICAL PHYSICS, 2012, 37 (04) : 207 - 213