Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement

被引:20
作者
Levesque, Thomas [1 ]
Eltchaninoff, Helene [1 ]
Chabannes, Romain [1 ]
Barbe, Thomas [1 ]
Dosseh, Olivier [1 ]
Tron, Christophe [1 ]
Bettinger, Nicolas [1 ]
Bouhzam, Najime [1 ]
Hemery, Thibaut [1 ]
le Pessec, Guillaume [1 ]
Fauvel, Charles [1 ]
Cribier, Alain [1 ]
Pibarot, Philippe [2 ]
Durand, Eric [1 ,3 ]
机构
[1] Normandie Univ, Dept Cardiol, UNIROUEN, U1096,CHU Rouen, Rouen, France
[2] Univ Laval, Inst Univ Cardiol & Pneumol Quebec, Dept Cardiol, Quebec City, PQ, Canada
[3] Charles Nicolle Hosp, Dept Cardiol, 1 rue Germont, Rouen, France
关键词
HIGH-RISK PATIENTS; CLINICAL IMPACT; TRIAL; CALCIFICATION; PREDICTORS; OUTCOMES; STENOSIS;
D O I
10.1016/j.cjca.2023.09.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Data on the long-term impact of prosthesis-patient mismatch (PPM) on outcomes after transcatheter aortic valve replacement (TAVR) remain sparse. We therefore aimed to investigate the incidence, predictive factors, and long-term prognostic impact of PPM on bioprosthesis durability and mortality. Methods: This was a single-centre retrospective study including 2117 patients who underwent TAVR for aortic stenosis from 2002 to 2022. Moderate PPM was defined by indexed effective orifice area (iEOA) > 0.65 and <= 0.85 cm(2)/m(2) (> 0.55 and <= 0.70 cm(2)/m(2) if BMI >= 30 kg/m(2)) and severe PPM by an iEOA <= 0.65 cm(2)/m(2) (<= 0.55 cm(2)/m(2) If BMI >= 30 kg/m(2)). Results: There were 351 patients (16.6%) with PPM, including 39 patients (1.8%) with severe PPM and 312 patients (14.7%) with moderate PPM. The mean follow-up duration was 31.2 +/- 26.5 months. Factors independently associated with the occurrence of PPM were body surface area (odds ratio [OR] 3.32, 95% confidence interval [CI] 1.32-8.35; P = 0.01), valve-in-valve TAVR (OR 6.12, 95% CI 2.29-16.08; P < 0.001), small annulus (OR 2.42, 95% CI 1.41-4.07; P = 0.001), and the use of a balloon-expandable valve (OR 4.17, 95% CI 2.17-8.33; P < 0.001). PPM was associated with increased risk of mortality (hazard ratio [HR] 1.3, 95% CI 1.1-1.5, P = 0.004) and valve thrombosis (HR 4.2, 95% CI 1.4-12.6, P = 0.01), and a trend towards increased risk of structural valve deterioration (HR 1.7, 95% CI 0.9-2.9; P = 0.08). Conclusions: The results of this study suggest that PPM has a negative long-term impact on outcomes after TAVR. These findings emphasise the importance of preventing PPM.
引用
收藏
页码:113 / 122
页数:10
相关论文
共 27 条
[1]   Bioprosthetic Valve Performance After Transcatheter Aortic Valve Replacement With Self-Expanding Versus Balloon-Expandable Valves in Large Versus Small Aortic Valve Annuli Insights From the CHOICE Trial and the CHOICE-Extend Registry [J].
Abdelghani, Mohammad ;
Mankerious, Nader ;
Allali, Abdelhakim ;
Landt, Martin ;
Kaur, Jatinderjit ;
Sulimov, Dmitriy S. ;
Merten, Constanze ;
Sachse, Susanne ;
Mehilli, Julinda ;
Neumann, Franz-Josef ;
Frerker, Christian ;
Kurz, Thomas ;
El-Mawardy, Mohamed ;
Richardt, Gert ;
Abdel-Wahab, Mohamed .
JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (24) :2507-2518
[2]   Surgical aortic valve replacement and patient-prosthesis mismatch: a meta-analysis of 108 182 patients [J].
Barros de Oliveira Sa, Michel Pompeu ;
Barros de Carvalho, Martinha Millianny ;
Sobral Filho, Dario Celestino ;
Pereira Cavalcanti, Luiz Rafael ;
Rayol, Sergio da Costa ;
Silva Diniz, Roberto Gouvea ;
Menezes, Alexandre Motta ;
Clavel, Marie-Annick ;
Pibarot, Philippe ;
Lima, Ricardo Carvalho .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 56 (01) :44-54
[3]   Long-Term Prognosis Value of Paravalvular Leak and Patient-Prosthesis Mismatch following Transcatheter Aortic Valve Implantation: Insight from the France-TAVI Registry [J].
Deharo, Pierre ;
Leroux, Lionel ;
Theron, Alexis ;
Ferrara, Jerome ;
Vaillier, Antoine ;
Jaussaud, Nicolas ;
Porto, Alizee ;
Morera, Pierre ;
Gariboldi, Vlad ;
Iung, Bernard ;
Lefevre, Thierry ;
Commeau, Philippe ;
Gouysse, Margaux ;
du Chayla, Florence ;
Glatt, Nicolas ;
Cayla, Guillaume ;
Le Breton, Herve ;
Benamer, Hakim ;
Beurtheret, Sylvain ;
Verhoye, Jean Philippe ;
Eltchaninoff, Helene ;
Gilard, Martine ;
Collet, Jean Philippe ;
Dumonteil, Nicolas ;
Collart, Frederic ;
Modine, Thomas ;
Cuisset, Thomas .
JOURNAL OF CLINICAL MEDICINE, 2022, 11 (20)
[4]   Five-Year Clinical Outcome and Valve Durability After Transcatheter Aortic Valve Replacement in High-Risk Patients: FRANCE-2 Registry [J].
Didier, Romain ;
Eltchaninoff, Helene ;
Donzeau-Gouge, Patrick ;
Chevreul, Karine ;
Fajadet, Jean ;
Leprince, Pascal ;
Leguerrier, Alain ;
Lievre, Michel ;
Prat, Alain ;
Teiger, Emmanuel ;
Lefevre, Thierry ;
Tchetche, Didier ;
Carrie, Didier ;
Himbert, Dominique ;
Albat, Bernard ;
Cribier, Alain ;
Sudre, Arnaud ;
Blanchard, Didier ;
Rioufol, Gilles ;
Collet, Frederic ;
Houel, Remi ;
Dos Santos, Pierre ;
Meneveau, Nicolas ;
Ghostine, Said ;
Manigold, Thibaut ;
Guyon, Philippe ;
Cuisset, Thomas ;
Le Breton, Herve ;
Delepine, Stephane ;
Favereau, Xavier ;
Souteyrand, Geraud ;
Ohlmann, Patrick ;
Doisy, Vincent ;
Lognone, Therese ;
Gommeaux, Antoine ;
Claudel, Jean-Philippe ;
Bourlon, Francois ;
Bertrand, Bernard ;
Iung, Bernard ;
Gilard, Martine .
CIRCULATION, 2018, 138 (23) :2597-2607
[5]   The Incidence and Consequence of Prosthesis-Patient Mismatch After Surgical Aortic Valve Replacement [J].
Fallon, John M. ;
DeSimone, Joseph P. ;
Brennan, J. Matthew ;
O'Brien, Sean ;
Thibault, Dylan P. ;
DiScipio, Anthony W. ;
Pibarot, Philippe ;
Jacobs, Jeffrey P. ;
Malenka, David J. ;
Clarizia, Nadia A. ;
Ruel, Marc .
ANNALS OF THORACIC SURGERY, 2018, 106 (01) :14-23
[6]   Prosthesis-Patient Mismatch Predicts Structural Valve Degeneration in Bioprosthetic Heart Valves [J].
Flameng, Willem ;
Herregods, Marie-Christine ;
Vercalsteren, Monique ;
Herijgers, Paul ;
Bogaerts, Kris ;
Meuris, Bart .
CIRCULATION, 2010, 121 (19) :2123-2129
[7]   Valve Academic Research Consortium 3: Updated Endpoint Definitions for Aortic Valve Clinical Research [J].
Genereux, Philippe ;
Piazza, Nicolo ;
Alu, Maria C. ;
Nazif, Tamim ;
Hahn, Rebecca T. ;
Pibarot, Philippe ;
Bax, Jeroen J. ;
Leipsic, Jonathon A. ;
Blanke, Philipp ;
Blackstone, Eugene H. ;
Finn, Matthew T. ;
Kapadia, Samir ;
Linke, Axel ;
Mack, Michael J. ;
Makkar, Raj ;
Mehran, Roxana ;
Popma, Jeffrey J. ;
Reardon, Michael ;
Rodes-Cabau, Josep ;
Van Mieghem, Nicolas M. ;
Webb, John G. ;
Cohen, David J. ;
Leon, Martin B. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (21) :2717-2746
[8]   The impact of prosthesispatient mismatch on long-term survival after aortic valve replacement: a systematic review and meta-analysis of 34 observational studies comprising 27 186 patients with 133 141 patient-years [J].
Head, Stuart J. ;
Mokhles, Mostafa M. ;
Osnabrugge, Ruben L. J. ;
Pibarot, Philippe ;
Mack, Michael J. ;
Takkenberg, Johanna J. M. ;
Bogers, Ad J. J. C. ;
Kappetein, Arie Pieter .
EUROPEAN HEART JOURNAL, 2012, 33 (12) :1518-1529
[9]   Prosthesis-Patient Mismatch in Patients Undergoing Transcatheter Aortic Valve Replacement From the STS/ACC TVT Registry [J].
Herrmann, Howard C. ;
Daneshvar, Samuel A. ;
Fonarow, Gregg C. ;
Stebbins, Amanda ;
Vemulapalli, Sreekanth ;
Desai, Nimesh D. ;
Malenka, David J. ;
Thourani, Vinod H. ;
Rymer, Jennifer ;
Kosinski, Andrzej S. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (22) :2701-2711
[10]   Predictors and Clinical Impact of Prosthesis-Patient Mismatch After Self-Expandable TAVR in Small Annuli [J].
Leone, Pier Pasquale ;
Regazzoli, Damiano ;
Pagnesi, Matteo ;
Sanz-Sanchez, Jorge ;
Chiarito, Mauro ;
Cannata, Francesco ;
Van Mieghem, Nicolas M. ;
Barbanti, Marco ;
Tamburino, Corrado ;
Teles, Rui ;
Adamo, Marianna ;
Miura, Mizuki ;
Maisano, Francesco ;
Kim, Won-Keun ;
Bedogni, Francesco ;
Stefanini, Giulio ;
Mangieri, Antonio ;
Giannini, Francesco ;
Colombo, Antonio ;
Reimers, Bernhard ;
Latib, Azeem .
JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (11) :1218-1228