Accuracy of digital impressions for three- unit and four-unit implant supported fixed dental prostheses using a novel device

被引:8
作者
Kao, Tzu-Yung [1 ]
Hsieh, Min-Chieh [1 ]
Liao, Chi -Chun [2 ,3 ]
Chang, Chih-Ling [1 ,4 ,5 ]
机构
[1] Shin Kong Wu Ho Su Mem Hosp, Dept Prosthodont, Taipei, Taiwan
[2] Natl Taiwan Univ Sci & Technol, High Speed Printing Res Ctr 3D, Taipei, Taiwan
[3] Jien Shin Dent Lab, Taipei, Taiwan
[4] Natl Yang Ming Chiao Tung Univ, Sch Dent, Taipei, Taiwan
[5] Shin Kong Wu Ho Su Mem Hosp, Dept Prosthodont, B1F,95 Wen Chang Rd, Taipei 11101, Taiwan
关键词
Accuracy; Digital impression; Intraoral scan body; Intraoral scanner; PRECISION;
D O I
10.1016/j.jds.2022.10.014
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background/ purpose: Accuracy of digital implant impressions was considered questionable due to the lack of anatomical reference points between implants and the similar-ities in scan body morphology, which lead to the purpose of this research is to propose a simple and convenient technique to improve the accuracy of scanning.Materials and methods: Four implant analogues (teeth: 15, 17, 24, and 27) were inserted into a stone model of a partially edentulous maxilla; two implants were inserted on each side, creating a three-unit span and a four-unit span. The model was scanned using a 3Shape E4 dental laboratory scanner for reference and a TRIOS 3 intraoral scanner for testing. Each side was scanned 10 times, both with and without the novel device attached to the scan bodies. The trueness and precision of interimplant distances (linear deviations), and interimplant an-gulations (angle deviations) between the scan bodies were determined using software. A Mann-Whitney U test was used to determine statistical differences between subgroups.Results: Significant differences were discovered in the trueness of angular deviations (-0.20 degrees +/- 0.15 degrees vs.-0.01 degrees +/- 0.11o) and precision of linear deviations (11.14 +/- 6.35 vs. 3.10 +/- 2.14 mm) for the four-unit groups.Conclusion: The novel device significantly improved scanning accuracy for a four-unit groups (approximately 22.93 mm) compared to three-unit groups. 2022 Association for Dental Sciences of the Republic of China. Publishing services by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/ licenses/by/4.0/).
引用
收藏
页码:702 / 708
页数:7
相关论文
共 42 条
  • [1] Implications of Implant Framework Misfit: A Systematic Review of Biomechanical Sequelae
    Abduo, Jaafar
    Judge, Roy B.
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (03) : 608 - 621
  • [2] Abduo J, 2011, INT J PROSTHODONT, V24, P207
  • [3] Digital Versus Conventional Impressions in Fixed Prosthodontics: A Review
    Ahlholm, Pekka
    Sipila, Kirsi
    Vallittu, Pekka
    Jakonen, Minna
    Kotiranta, Ulla
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (01): : 35 - 41
  • [4] Accuracy of Digital Dental Implants Impression Taking with Intraoral Scanners Compared with Conventional Impression Techniques: A Systematic Review of In Vitro Studies
    Albanchez-Gonzalez, Maria Isabel
    Brinkmann, Jorge Cortes-Breton
    Pelaez-Rico, Jesus
    Lopez-Suarez, Carlos
    Rodriguez-Alonso, Veronica
    Suarez-Garcia, Maria Jesus
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (04)
  • [5] Digital Implant Impression Technique Accuracy: A Systematic Review
    Alikhasi, Marzieh
    Alsharbaty, Mohammed Hussein M.
    Moharrami, Mohammad
    [J]. IMPLANT DENTISTRY, 2017, 26 (06) : 929 - 935
  • [6] Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles: A pilot study
    Andriessen, Frank S.
    Riikens, David R.
    van der Meer, Wither J.
    Wismeijer, Daniell W.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (03) : 186 - 194
  • [7] [Anonymous], 1994, Accuracy (trueness and precision) of measurement methods and results - Part 1: General principies and defmitions
  • [8] Trueness and precision of 5 intraoral scanners for scanning edentulous and dentate complete-arch mandibular casts: A comparative in vitro study
    Braian, Michael
    Wennerberg, Ann
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (02) : 129 - 136
  • [9] OSSEOINTEGRATION AND ITS EXPERIMENTAL BACKGROUND
    BRANEMARK, PI
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1983, 50 (03) : 399 - 410
  • [10] Buzayan Muaiyed Mahmoud, 2014, J Indian Prosthodont Soc, V14, P16, DOI 10.1007/s13191-013-0343-x