Does the universal adhesive's film thickness affect dentin-bonding effectiveness?

被引:7
作者
Tang, Chuliang [1 ,2 ]
Mercelis, Ben [1 ,2 ]
Yoshihara, Kumiko [3 ,4 ]
Peumans, Marleen [1 ,2 ]
Van Meerbeek, Bart [1 ,2 ]
机构
[1] KU Leuven Univ Leuven, Dept Oral Hlth Sci, BIOMAT Biomat Res Grp, Kapucijnenvoer 7 Blok A Bus 7001, B-3000 Leuven, Belgium
[2] UZ Leuven Univ Hosp Leuven, Dent, Kapucijnenvoer 7 Blok A Bus 7001, B-3000 Leuven, Belgium
[3] Natl Inst Adv Ind Sci & Technol, Hlth & Med Res Inst, Takamatsu, Kagawa 7610395, Japan
[4] Okayama Univ, Grad Sch Med Dent & Pharmaceut Sci, Dept Pathol & Expt Med, Okayama 7008558, Japan
关键词
Adhesive; Interface; Durability; Class I; Bonding; IN-ONE ADHESIVE; DOUBLE-LAYER APPLICATION; HEMA-FREE; C-FACTOR; POLYMERIZATION SHRINKAGE; OXYGEN INHIBITION; TECHNIQUE SENSITIVITY; CONTRACTION STRESS; COMPOSITE RESIN; STRENGTH;
D O I
10.1007/s00784-024-05523-7
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives To investigate the influence of adhesive resin application modalities on the film thickness of the adhesive resin and the effectiveness of a two-step universal adhesive (UA) bonded in self-etch (SE) bonding mode to high C-factor class-I cavity-bottom dentin. Materials and methods After application of the primer of G2-Bond Universal (G2B, GC), the adhesive resin was applied into standard class-I cavities (human molars) following four application modalities: (1) one layer, strongly air-blown; (2) one layer, gently air-blown; (3) two layers, each gently air-blown; (4) one layer, not air-blown. After being restored with composite, each tooth was sectioned to obtain one micro-specimen (n = 10), of which the adhesive resin film thickness was measured using optical microscopy. The micro-tensile bond strength (mu TBS) was tested immediately or upon 100,000 thermocycles. Statistical analyses involved Kruskal-Wallis and Mann-Whitney U testing (p < 0.05). Results G2B's mu TBS was significantly affected by the adhesive resin application modality and aging. Gently air-blowing the adhesive resin resulted in significantly higher immediate mu TBS than strong air-blowing or no air-blowing. No significant difference in mu TBS was found between single or double gently air-blown adhesive resin applications. The adhesive resin film thickness significantly varied with the application modalities. Conclusions A too thin or too thick adhesive resin film thickness adversely affected bond strength of the two-step UA applied in SE mode and high C-factor condition. Clinical relevance The adhesive resin layer thickness can affect the bonding performance of two-step UAs in high C-factor cavities. Dental clinicians remain advised to avoid improper air-blowing of UAs and strictly follow the application instructions.
引用
收藏
页数:10
相关论文
共 49 条
[1]   Extra Bonding Layer Compensates Universal Adhesive's Thin Film Thickness [J].
Ahmed, Mohammed H. ;
Yao, Chenmin ;
Van Landuyt, Kirsten ;
Peumans, Marleen ;
Van Meerbeek, Bart .
JOURNAL OF ADHESIVE DENTISTRY, 2020, 22 (05) :483-501
[2]   Academy of Dental Materials guidance on in vitro testing of dental composite bonding effectiveness to dentin/enamel using micro-tensile bond strength (μTBS) approach [J].
Armstrong, Steve ;
Breschi, Lorenzo ;
Ozcan, Mutlu ;
Pfefferkorn, Frank ;
Ferrari, Marco ;
Van Meerbeek, Bart .
DENTAL MATERIALS, 2017, 33 (02) :133-143
[3]   Factors involved in the development of polymerization shrinkage stress in resin-composites: A systematic review [J].
Braga, RR ;
Ballester, RY ;
Ferracane, JL .
DENTAL MATERIALS, 2005, 21 (10) :962-970
[4]   Degree of conversion and permeability of dental adhesives [J].
Cadenaro, M ;
Antoniolli, F ;
Sauro, S ;
Tay, FR ;
Di Lenarda, R ;
Prati, C ;
Biasotto, M ;
Contardo, L ;
Breschi, L .
EUROPEAN JOURNAL OF ORAL SCIENCES, 2005, 113 (06) :525-530
[5]   The effects of adhesive thickness on polymerization contraction stress of composite [J].
Choi, KK ;
Condon, JR ;
Ferracane, JL .
JOURNAL OF DENTAL RESEARCH, 2000, 79 (03) :812-817
[6]   Clinical performance and chemical-physical properties of bulk fill composites resin -a systematic review and meta-analysis [J].
Cidreira Boaro, Leticia Cristina ;
Lopes, Diana Pereira ;
Caetano de Souza, Andreia Santos ;
Nakano, Ellea Lie ;
Ayala Perez, Mirko Dennys ;
Pfeifer, Carmem Silvia ;
Goncalves, Flavia .
DENTAL MATERIALS, 2019, 35 (10) :E249-E264
[7]  
D'Arcangelo C, 2009, J ADHES DENT, V11, P109
[8]   A critical review of the durability of adhesion to tooth tissue: Methods and results [J].
De Munck, J ;
Van Landuyt, K ;
Peumans, M ;
Poitevin, A ;
Lambrechts, P ;
Braem, M ;
Van Meerbeek, B .
JOURNAL OF DENTAL RESEARCH, 2005, 84 (02) :118-132
[9]  
De Munck J, 2007, J ADHES DENT, V9, P373
[10]   NaOCl degradation of a HEMA-free all-in-one adhesive bonded to enamel and dentin following two air-blowing techniques [J].
De Munck, Jan ;
Ermis, R. Banu ;
Koshiro, Kenichi ;
Inoue, Satoshi ;
Ikeda, Takatsumi ;
Sano, Hidehiko ;
Van Landuyt, Kirsten L. ;
Van Meerbeek, Bart .
JOURNAL OF DENTISTRY, 2007, 35 (01) :74-83