Can virtual non-contrast imaging replace true non-contrast imaging in multiphase scanning of the neck region?

被引:7
作者
Al-Difaie, Zaid [1 ]
Scheepers, Max H. M. C. [1 ]
Bouvy, Nicole D. [2 ]
Engelen, Sanne [2 ]
Havekes, Bas [3 ]
Postma, Alida A. [4 ,5 ]
机构
[1] Maastricht Univ, GROW Sch Oncol & Dev Biol, Maastricht, Netherlands
[2] Maastricht Univ, Dept Surg, Med Ctr, Maastricht, Netherlands
[3] Maastricht Univ, Med Ctr, Dept Internal Med, Div Endocrinol & Metab Dis, Maastricht, Netherlands
[4] Maastricht Univ, Sch Mental Hlth & Neurosci, Dept Radiol & Nucl Med, Neuroradiol,Med Ctr, Maastricht, Netherlands
[5] Maastricht Univ, Sch Mental Hlth & Neurosci, Dept Radiol & Nucl Med, Neuroradiol,Med Ctr, POB 5800, NL-6229 ER Maastricht, Netherlands
关键词
diagnostic; computed tomography; head and neck; dual-energy CT; virtual non-contrast imaging; DUAL-ENERGY CT; COMPUTED-TOMOGRAPHY; PARATHYROID ADENOMAS; NONCONTRAST IMAGES; HEAD;
D O I
10.1177/20584601231205159
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Dual-energy computed tomography (DECT) is an advanced imaging method that enables reconstruction of virtual non-contrast (VNC) images from a contrast-enhanced acquisition. This has the potential to reduce radiation exposure by eliminating the need for a true non-contrast (TNC) phase.PurposeThe purpose is to evaluate the feasibility of VNC images in the neck region.Materials and methods: A total of 100 patients underwent a DECT scan as part of diagnostic workup of primary hyperparathyroidism. VNC images were reconstructed from 30 s (arterial) and 50 s (venous) post-contrast scans. Regions of interest (ROIs) were placed in thyroid tissue, lymph node, carotid artery, jugular vein, fat, and sternocleidomastoid muscle. Mean densities of all anatomical structures were compared between VNC and TNC images.Results: For all anatomical structures except the thyroid gland, the difference in mean density between TNC and VNC images was less than 15 HU. The mean difference in density between TNC and VNC images of the thyroid was 53.2 HU (95% CI 46.8; 59.6, p = <0.001).Conclusion: This study demonstrated an acceptable agreement in density between true non-contrast and virtual non-contrast images for most anatomical structures in the neck region. Therefore, VNC images may have the potential to replace TNC images in the neck. However, due to significant differences in CT density of thyroid tissue, true non-contrast imaging cannot be directly substituted by virtual non-contrast imaging when examining the thyroid and its surrounding tissue.
引用
收藏
页数:7
相关论文
共 26 条
[1]   Assessment of an Advanced Monoenergetic Reconstruction Technique in Dual-Energy Computed Tomography of Head and Neck Cancer [J].
Albrecht, Moritz H. ;
Scholtz, Jan-Erik ;
Kraft, Johannes ;
Bauer, Ralf W. ;
Kaup, Moritz ;
Dewes, Patricia ;
Bucher, Andreas M. ;
Burck, Iris ;
Wagenblast, Jens ;
Lehnert, Thomas ;
Kerl, J. Matthias ;
Vogl, Thomas J. ;
Wichmann, Julian L. .
EUROPEAN RADIOLOGY, 2015, 25 (08) :2493-2501
[2]   Virtual unenhanced second generation dual-source CT of the liver: Is it time to discard the conventional unenhanced phase? [J].
Barrett, T. ;
Bowden, D. J. ;
Shaida, N. ;
Godfrey, E. M. ;
Taylor, A. ;
Lomas, D. J. ;
Shaw, A. S. .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (07) :1438-1445
[3]   Dual-Energy Parathyroid 4D-CT: Improved Discrimination of Parathyroid Lesions from Thyroid Tissue Using Noncontrast 40-keV Virtual Monoenergetic Images [J].
Bunch, P. M. ;
Pavlina, A. A. ;
Lipford, M. E. ;
Sachs, J. R. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2021, 42 (11) :2001-2008
[4]   Advanced dual-energy CT applications for the evaluation of the soft tissues of the neck [J].
Forghani, R. ;
Mukherji, S. K. .
CLINICAL RADIOLOGY, 2018, 73 (01) :70-80
[5]   Dual-Energy CT Characteristics of Parathyroid Adenomas on 25-and 55-Second 4D-CT Acquisitions: Preliminary Experience [J].
Forghani, Reza ;
Roskies, Michael ;
Liu, Xiaoyang ;
Tan, Xianming ;
Mlynarek, Alex ;
Payne, Richard J. ;
Nair, Jaykumar R. ;
Hier, Michael P. ;
Levental, Mark .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (05) :806-814
[6]   Identification of benign and malignant thyroid nodules by in vivo iodine concentration measurement using single-source dual energy CT: A retrospective diagnostic accuracy study [J].
Gao, Shun-Yu ;
Zhang, Xiao-Yan ;
Wei, Wei ;
Li, Xiao-Ting ;
Li, Yan-Ling ;
Xu, Min ;
Sun, Ying-Shi ;
Zhang, Xiao-Peng .
MEDICINE, 2016, 95 (39)
[7]   Performance of virtual non-contrast images generated on clinical photon-counting detector CT for emphysema quantification: proof of concept [J].
Jungblut, Lisa ;
Sartoretti, Thomas ;
Kronenberg, Daniel ;
Mergen, Victor ;
Euler, Andre ;
Schmidt, Bernhard ;
Alkadhi, Hatem ;
Frauenfelder, Thomas ;
Martini, Katharina .
BRITISH JOURNAL OF RADIOLOGY, 2022, 95 (1135)
[8]   Advanced Computed Tomographic Localization Techniques for Primary Hyperparathyroidism A Systematic Review and Meta-analysis [J].
Kattar, Nrusheel ;
Migneron, Matthew ;
Debakey, Michael S. ;
Haidari, Muhib ;
Pou, Anna M. ;
McCoul, Edward D. .
JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2022, 148 (05) :448-456
[9]   Detection of parathyroid adenomas using a monophasic dual-energy computed tomography acquisition: diagnostic performance and potential radiation dose reduction [J].
Leiva-Salinas, Carlos ;
Flors, Lucia ;
Durst, Christopher R. ;
Hou, Qinghua ;
Patrie, James T. ;
Wintermark, Max ;
Mukherjee, Sugoto .
NEURORADIOLOGY, 2016, 58 (11) :1135-1141
[10]   Attenuation values of renal parenchyma in virtual noncontrast images acquired from multiphase renal dual-energy CT: Comparison with standard noncontrast CT [J].
Lin, Yuan-Mao ;
Chiou, Yi-You ;
Wu, Mei-Han ;
Huang, Shan-Su ;
Shen, Shu-Huei .
EUROPEAN JOURNAL OF RADIOLOGY, 2018, 101 :103-110