Continuous Glucose Monitoring to Optimize Management of Diabetes in Patients with Advanced CKD

被引:28
作者
Galindo, Rodolfo J. J. [1 ,7 ]
Boer, Ian H. de H. [2 ]
Neumiller, Joshua J. J. [3 ]
Tuttle, Katherine R. R. [4 ,5 ,6 ]
机构
[1] Emory Univ, Sch Med, Div Endocrinol, Atlanta, GA USA
[2] Univ Washington, Kidney Res Inst, Seattle, WA USA
[3] Washington State Univ, Coll Pharm & Pharmaceut Sci, Dept Pharmacotherapy, Spokane, WA USA
[4] Univ Washington, Kidney Res Inst, Nephrol Div, Seattle, WA USA
[5] Univ Washington, Inst Translat Hlth Sci, Seattle, WA USA
[6] Providence Hlth Care, Providence Med Res Ctr, Spokane, WA USA
[7] Emory Univ, Sch Med, 69 Jesse Hill Jr Dr,Glenn Bldg,Suite 202, Atlanta, GA 30303 USA
来源
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY | 2023年 / 18卷 / 01期
关键词
chronic dialysis; chronic kidney disease; diabetes; diabetes mellitus; end-stage renal disease; continuous glucose monitoring; CGM; STAGE RENAL-DISEASE; DAILY INSULIN INJECTIONS; QUALITY-OF-LIFE; KIDNEY-DISEASE; SENSING TECHNOLOGY; COMPLICATIONS TRIAL/EPIDEMIOLOGY; GLYCEMIC CONTROL; INHIBITORS; US ADULTS; TYPE-1;
D O I
10.2215/CJN.04510422
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Treatment of patients with diabetes and CKD includes optimizing glycemic control using lifestyle modifications and drugs that safely control glycemia and improve clinical kidney and cardiovascular disease outcomes. However, patients with advanced CKD, defined as eGFR <30 ml/min per 1.73 m(2) or kidney disease treated with dialysis, have limitations to the use of some preferred glucose-lowering medications, are often treated with insulin, and experience high rates of severe hypoglycemia. Moreover, hemoglobin A1c accuracy decreases as GFR deteriorates. Hence, there is a need for better glycemic monitoring tools. Continuous glucose monitoring allows for 24-hour glycemic monitoring to understand patterns and the effects of lifestyle and medications. Real-time continuous glucose monitoring can be used to guide the administration of insulin and noninsulin therapies. Continuous glucose monitoring can overcome the limitations of self-monitored capillary glucose testing and hemoglobin A1c and has been shown to prevent hypoglycemic excursions in some populations. More data are needed to understand whether similar benefits can be obtained for patients with diabetes and advanced CKD. This review provides an updated approach to management of glycemia in advanced CKD, focusing on the role of continuous glucose monitoring in this high-risk population.
引用
收藏
页码:130 / 145
页数:16
相关论文
共 50 条
[41]   Importance of continuous glucose monitoring in the treatment of diabetes mellitus [J].
Moon, Sun Joon ;
Lee, Won-Young .
JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, 2023, 66 (07) :432-438
[42]   Continuous Glucose Monitoring: Review of an Innovation in Diabetes Management [J].
Mian, Zainab ;
Hermayer, Kathie L. ;
Jenkins, Alicia .
AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2019, 358 (05) :332-339
[43]   Randomized comparison of self-monitored blood glucose (BGM) versus continuous glucose monitoring (CGM) data to optimize glucose control in type 2 diabetes [J].
Bergenstal, Richard M. ;
Mullen, Deborah M. ;
Strock, Ellie ;
Johnson, Mary L. ;
Xi, Min X. .
JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2022, 36 (03)
[44]   Comparison of accuracy between flash glucose monitoring and continuous glucose monitoring in patients with type 2 diabetes mellitus undergoing hemodialysis [J].
Matoba, Kenta ;
Hayashi, Akinori ;
Shimizu, Naoya ;
Moriguchi, Ibuki ;
Kobayashi, Naoyuki ;
Shichiri, Masayoshi .
JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2020, 34 (11)
[45]   The Effectiveness of Continuous Glucose Monitoring in Patients with Type 2 Diabetes: A Systematic Review of Literature and Meta-analysis [J].
Park, Cindy ;
Le, Quang A. .
DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 (09) :613-621
[46]   Continuous glucose monitoring in hemodialyzed patients with type 2 diabetes: a multicenter pilot study [J].
Kepenekian, Lori ;
Smagala, Agnieszka ;
Meyer, Laurent ;
Imhoff, Olivier ;
Alenabi, Farideh ;
Serb, Liviu ;
Fleury, Dominique ;
Dorey, Francois ;
Krummel, Thierry ;
Le Floch, Jean-Pierre ;
Chantrel, Francois ;
Kessler, Laurence .
CLINICAL NEPHROLOGY, 2014, 82 (04) :240-246
[47]   Personal continuous glucose monitoring (CGM) in diabetes management: Review of the literature and implementation for practical use [J].
Joubert, M. ;
Reznik, Y. .
DIABETES RESEARCH AND CLINICAL PRACTICE, 2012, 96 (03) :294-305
[48]   Implementation Strategies for Inpatient Continuous Glucose Monitoring-based Diabetes Management: A Systematic Review [J].
Olsen, Mikkel T. ;
Liarakos, Alexandros L. ;
Wilmot, Emma G. ;
Dhatariya, Ketan ;
Thabit, Hood ;
Sanchez-Garcia, David ;
Norgaard, Kirsten ;
Pedersen-Bjergaard, Ulrik ;
Hansen, Katrine B. ;
Vangoitsenhoven, Roman ;
Mathieu, Chantal ;
Kristensen, Peter L. ;
Mader, Julia K. .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2025, 110 (07) :e2411-e2419
[49]   Long-Term Effects of Initiating Continuous Subcutaneous Insulin Infusion (CSII) and Continuous Glucose Monitoring (CGM) in People with Type 1 Diabetes and Unsatisfactory Diabetes Control [J].
Senn, Jon-Duri ;
Fischli, Stefan ;
Slahor, Lea ;
Schelbert, Susanne ;
Henzen, Christoph .
JOURNAL OF CLINICAL MEDICINE, 2019, 8 (03)
[50]   Budget Impact of the Flash Continuous Glucose Monitoring System in Medicaid Diabetes Beneficiaries Treated with Intensive Insulin Therapy [J].
Frank, Jerry R. ;
Blissett, Deirdre ;
Hellmund, Richard ;
Virdi, Naunihal .
DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 :S36-S44