Multiplexed bead-based assay for the simultaneous quantification of human serum IgG antibodies to tetanus, diphtheria, pertussis toxin, filamentous hemagglutinin, and pertactin

被引:6
作者
Rathod, Vishal [1 ]
Kadam, Laxmikant [1 ]
Gautam, Manish [1 ]
Gumma, Prabhu Dasu [1 ]
Marke, Kevin [2 ]
Asokanathan, Cathy [2 ]
Douglas-Bardsley, Alex [2 ]
Hassell, Laura [2 ]
Bhandare, Sachin [1 ]
Gupta, Sumit [1 ]
Parekh, Sameer [1 ]
Pujari, Pramod [1 ]
Rao, Harish [1 ]
Sharma, Hitt [1 ]
Shaligram, Umesh [1 ]
Gairola, Sunil [1 ]
机构
[1] Serum Inst India Pvt Ltd, Clin Bioanalyt Lab, Pune, Maharashtra, India
[2] Sci Res & Innovat Med & Healthcare Prod Regulatory, South Mimms, England
来源
FRONTIERS IN IMMUNOLOGY | 2023年 / 14卷
关键词
diphtheria; enzyme-linked immunosorbent assay (ELISA); Luminex (xMAP) method; multiplex immunoassay (MIA); pertussis; tetanus; LINKED-IMMUNOSORBENT-ASSAY; BORDETELLA-PERTUSSIS; VACCINES; ELISA; IMMUNOGLOBULIN;
D O I
10.3389/fimmu.2023.1190404
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background: Luminex bead-based assays offer multiplexing to test antibodies against multiple antigens simultaneously; however, this requires validation using internationally certified reference standards. Therefore, there is an urgent need to characterize existing reference standards for the standardization of multiplex immunoassays (MIAs). Here, we report the development and validation of an MIA for the simultaneous estimation of levels of human serum immunoglobulin G (IgG) antibodies for pertussis toxin ( PT), filamentous hemagglutinin ( FHA), pertactin (PRN), diphtheria toxoid (DT), and tetanus toxoid (TT). Methods: The MIA was assessed using a panel of human serum samples and WHO reference standards. The WHO reference standards were also studied for suitability in the MIA. Purified antigens (PT, FHA, PRN, DT, and TT) were coupled to the spectrally unique magnetic carboxylated microspheres. The method was validated in accordance with the United States Food and Drug Administration (US FDA), European Medicines Agency (EMA), and the International Committee of Harmonization Multidisciplinary (ICH M10) guidelines, and parameters such as precision, accuracy, dilutional linearity, assay range, robustness, and stability were assessed. Method agreements with commercially available IgG enzymelinked immunosorbent assay (ELISA) assays were also evaluated. In addition, the study assessed the level of correlation between the IgG levels estimated by the MIA and the cell-based neutralizing antibody assays for PT and DT. Results: We identified that an equimix of WHO international standards (i.e., 06/ 142, 10/262, and TE-3) afforded the best dynamic range for all the antigens in the MIA. For all five antigens, we observed that the back-fitted recoveries using the four-parameter logistic (4-PL) regression fits ranged between 80% and 120% for all calibration levels, and the percentage coefficient of variation (% CV) was < 20%. In addition, the difference in mean fluorescence intensity (MFI) between the monoplex and multiplex format was < 10% for each antigen, indicating no crosstalk among the beads. The MIA also showed good agreement with conventional and commercially available assays, and a positive correlation (> 0.75) with toxin neutralization assays for PT and DT was observed. Conclusion: The MIA that was calibrated in accordance with WHO reference standards demonstrated increased sensitivity, reproducibility, and high throughput capabilities, allowing for the design of robust studies that evaluate both natural and vaccine-induced immunity.
引用
收藏
页数:20
相关论文
共 3 条
  • [1] ACQUISITION OF IGG SERUM ANTIBODIES AGAINST 2 BORDETELLA ANTIGENS (FILAMENTOUS HEMAGGLUTININ AND PERTACTIN) IN CHILDREN WITH NO SYMPTOMS OF PERTUSSIS
    ISACSON, J
    TROLLFORS, B
    TARANGER, J
    LAGERGARD, R
    PEDIATRIC INFECTIOUS DISEASE JOURNAL, 1995, 14 (06) : 517 - 521
  • [2] Development and validation of magnetic bead pentaplex immunoassay for simultaneous quantification of murine serum IgG antibodies to acellular pertussis, diphtheria and tetanus antigens used in combination vaccines
    Kadam, Laxmikant
    Patel, Krunal
    Gautam, Manish
    Thorat, Shrikant
    Kale, Prathamesh
    Ghule, Arvind Kumar
    Gairola, Akansha
    Rao, Harish
    Shinde, Yojana
    Shaligram, Umesh
    Gairola, Sunil
    METHODS, 2019, 158 : 33 - 43
  • [3] Development of a Bead-Based Multiplexed Assay for Simultaneous Quantification of Five Bovine Cytokines by Flow Cytometry
    Rodrigues, Valerie
    Baudier, Jean Baptiste
    Chantal, Isabelle
    CYTOMETRY PART A, 2017, 91A (09) : 901 - 907