Study on Development Characteristics of Partial Discharge in Oil-Pressboard Insulation under Constant DC Voltage

被引:1
作者
Zhang, Chengjie [1 ]
Li, Yuan [1 ]
Yang, Senhong [1 ]
Li, Ranran [1 ]
机构
[1] Sichuan Univ, Coll Elect Engn, 24 Yihuan Rd, Chengdu 610065, Peoples R China
关键词
oil-pressboard insulation; partial discharge; DC voltage;
D O I
10.3390/en16103970
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The converter transformer is the core equipment of HVDC transmission system, the valve-side winding of which needs to withstand DC voltage. Partial discharge is one of the main threats to the safe operation of converter transformer, yet the characteristics of partial discharge development of the oil-pressboard insulations under constant DC voltage are insufficiently understood. In order to better understand the partial discharge characteristics of the oil-pressboard insulation under DC voltage and provide deeper theoretical support for insulation diagnosis of converter transformers, development characteristics including the time-varying tendency of discharge magnitude and repetition rate of partial discharge in oil-pressboard insulation under constant positive and negative DC voltage were studied. The results indicate that the development of partial discharge in a needle-plane oil-pressboard insulation model under constant DC voltage has three stages: the intensive discharging stage, the silent-burst stage, and the breakdown stage. Throughout all stages, the partial discharge magnitude and repetition rate first decrease and increase afterwards. At the silent-burst stage, the partial discharge appears in the form of a "cluster" with very large magnitude and repetition rate. Each cluster exists for tens of seconds but with at a very long interval with each other. Further analysis shows that the repeated accumulation and dissipation of free charges on the surface of the pressboard cause the above phenomena. Negative charges are easy to accumulate and difficult to dissipate under the same voltage amplitude compared to positive charges, leading to a weaker actual electric field at the needle tip and thus partial discharges under negative DC voltage with a lower magnitude and longer interval.
引用
收藏
页数:14
相关论文
共 50 条
[41]   Influence of PD Between Needle and Plate Electrodes on Oil-Pressboard Aging Under Combined AC-DC Voltage [J].
Xue, Zhitong ;
Liu, Hongshun ;
Guo, Ning ;
Guo, Jiahao ;
Xiao, Xiaolong ;
Shi, Mingming ;
Fang, Xin ;
Cong, Haoxi .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (03) :1288-1295
[42]   The Effect of the Non-uniformity in Dielectric Material on Spatial Distributions of Electric Field in a Parallel Plain Electrodes with Oil-pressboard Composite Insulation under DC Voltage [J].
Gao, Chunjia ;
Qi, Bo ;
Li, Chengrong .
2020 8TH INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD 2020), 2020, :306-309
[43]   An Image-Oriented Recognition Method for PD Development Stage in Oil-Pressboard Insulation with Needle-Plate Model under AC-DC Mixed Voltage [J].
Li, Simeng ;
Li, Qingquan ;
Si, Wen ;
Yao, Junyan .
2017 1ST INTERNATIONAL CONFERENCE ON ELECTRICAL MATERIALS AND POWER EQUIPMENT (ICEMPE), 2017, :275-282
[44]   AC Partial Discharge Characteristics in Ester Oil/Pressboard Composite Insulation System with Metallic Protrusion [J].
Hamasuna, Kyouhei ;
Kozako, Masahiro ;
Hikita, Masayuki ;
Yoshida, Shigeyoshi ;
Yamanaka, Yuta ;
Umemoto, Takahiro .
2022 IEEE 21ST INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS (ICDL), 2022,
[45]   Degradation mechanism of oil-pressboard insulation by multiphysical field aging characteristics and cellulose crytallinity [J].
Wang, Guan ;
Yan, Kuo ;
Zhao, Zhongyu ;
Li, Zihao ;
Liu, Hongshun ;
Li, Qingquan .
CELLULOSE, 2024, 31 (16) :9945-9961
[46]   Space Electric Field Characteristics in Oil of Large-Scale Oil-Pressboard Structure under Various Voltage Stresses [J].
Gao C. ;
Qi B. ;
Han H. ;
Gao Y. ;
Li C. .
Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2019, 34 (22) :4816-4826
[47]   A Recognition Method for PD Development Stage in Oil-pressboard Insulation with Needle-plate Model at AC-DC Mixed Voltage Based on Radar Maps [J].
Li S. ;
Li Q. ;
Liu H. ;
Yao J. ;
Zhao Y. ;
Han K. .
Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2018, 38 (19) :5897-5908
[48]   Partial Discharge Characteristics over Differently Aged Oil/pressboard Interfaces [J].
Li, Junhao ;
Si, Wenrong ;
Yao, Xiu ;
Li, Yanming .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2009, 16 (06) :1640-1647
[49]   Influencing Mechanism of Adhesive on Partial Discharge of Pressboard Block under AC/DC Composite Voltage [J].
Zhang, Yi ;
Qi, Bo ;
Ma, Yukun ;
Huang, Meng ;
Yuan, Qing ;
Lv, Yuzhen ;
Jiao, Yanqiu ;
Li, Chengrong ;
Zhang, Shuqi .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2021, 28 (06) :1883-1891
[50]   Partial discharge process in transformer oil and electrical insulation paper under DC stress [J].
Sha, Yanchao ;
Zhou, Yuanxiang ;
Nie, Dexin ;
Wu, Zhirong ;
Deng, Jiangang ;
Lu, Licheng .
Gaodianya Jishu/High Voltage Engineering, 2014, 40 (01) :80-86