Study on Development Characteristics of Partial Discharge in Oil-Pressboard Insulation under Constant DC Voltage

被引:1
|
作者
Zhang, Chengjie [1 ]
Li, Yuan [1 ]
Yang, Senhong [1 ]
Li, Ranran [1 ]
机构
[1] Sichuan Univ, Coll Elect Engn, 24 Yihuan Rd, Chengdu 610065, Peoples R China
关键词
oil-pressboard insulation; partial discharge; DC voltage;
D O I
10.3390/en16103970
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The converter transformer is the core equipment of HVDC transmission system, the valve-side winding of which needs to withstand DC voltage. Partial discharge is one of the main threats to the safe operation of converter transformer, yet the characteristics of partial discharge development of the oil-pressboard insulations under constant DC voltage are insufficiently understood. In order to better understand the partial discharge characteristics of the oil-pressboard insulation under DC voltage and provide deeper theoretical support for insulation diagnosis of converter transformers, development characteristics including the time-varying tendency of discharge magnitude and repetition rate of partial discharge in oil-pressboard insulation under constant positive and negative DC voltage were studied. The results indicate that the development of partial discharge in a needle-plane oil-pressboard insulation model under constant DC voltage has three stages: the intensive discharging stage, the silent-burst stage, and the breakdown stage. Throughout all stages, the partial discharge magnitude and repetition rate first decrease and increase afterwards. At the silent-burst stage, the partial discharge appears in the form of a "cluster" with very large magnitude and repetition rate. Each cluster exists for tens of seconds but with at a very long interval with each other. Further analysis shows that the repeated accumulation and dissipation of free charges on the surface of the pressboard cause the above phenomena. Negative charges are easy to accumulate and difficult to dissipate under the same voltage amplitude compared to positive charges, leading to a weaker actual electric field at the needle tip and thus partial discharges under negative DC voltage with a lower magnitude and longer interval.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Partial Discharge Detection Method in Oil-pressboard Insulation Based on Ultra-wideband Method
    Hou K.
    Wang Q.
    Lu X.
    Si W.
    Fu C.
    Li Q.
    Gaodianya Jishu/High Voltage Engineering, 2022, 48 (12): : 4770 - 4779
  • [42] Partial Discharge Process and Characteristics of Oil-Paper Insulation under Pulsating DC Voltage
    Bao, Lianwei
    Li, Jian
    Zhang, Jing
    Jiang, Tianyan
    Li, Xudong
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2016, 11 (02) : 437 - 445
  • [43] Partial Discharge Characteristics caused by Metallic Particles under DC voltage on Oil Immersed Insulation
    Miyaji, Yoshitaka
    Kainaga, Soichiro
    Yoshimura, Manabu
    Muto, Hirotaka
    Suga, Kenichi
    2019 IEEE 20TH INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS (ICDL), 2019,
  • [44] Effects of temperature on creepage discharge characteristics in oil-impregnated pressboard insulation under combined AC–DC voltage
    金福宝
    周远翔
    梁斌
    周仲柳
    张灵
    Plasma Science and Technology, 2019, 21 (05) : 16 - 24
  • [45] Effects of temperature on creepage discharge characteristics in oil-impregnated pressboard insulation under combined AC–DC voltage
    金福宝
    周远翔
    梁斌
    周仲柳
    张灵
    Plasma Science and Technology, 2019, (05) : 16 - 24
  • [46] Investigation on Dynamic Diffusion Behavior of Furfural in Oil-Pressboard Insulation under Partial Oil Replacement Condition
    Liu, Jiefeng
    Geng, Chuhan
    Fan, Xianhao
    Zhang, Yiyi
    Zhang, Heng
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2021, 28 (03) : 1044 - 1052
  • [47] Characteristics of Partial Discharge in the Oil Gap Separated by Pressboard Barrier in Oil/Pressboard Composite Insulation System
    Umemoto, T.
    Kainaga, S.
    Muto, H.
    Tsurimoto, T.
    Yoshida, S.
    Kozako, M.
    Hikita, M.
    PROCEEDINGS OF THE 2014 IEEE 18TH INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS (ICDL 2014), 2014,
  • [48] Effect of Temperature on Creeping Flashover Voltage of Nanofilled Oil-Pressboard Insulation
    Ibrahim, Mohamed E.
    Nassar, Alyaa A.
    Izzularab, Mohamed A.
    Abd-Elhady, Amr M.
    IEEE ACCESS, 2020, 8 : 227222 - 227231
  • [49] Effects of DC Prestressing on Partial Discharge in Oil-impregnated Pressboard Insulation
    Zhou, Y. X.
    Jin, F. B.
    Huang, M.
    Huang, J. W.
    Liu, Z. H.
    Lu, L. C.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (01) : 460 - 468
  • [50] PD Classification in Oil-pressboard Insulation by Simulating a Needle-plate Model with plus DC Voltage
    Li, Simeng
    Li, Qingquan
    He, Dongxin
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2019, 26 (01) : 261 - 269