Characterization of an Inter-digitated Sensor for Non-invasive Blood-glucose Sensing

被引:1
|
作者
Satish [1 ,2 ]
Sen, Kushal [3 ]
机构
[1] Indian Inst Technol, Ctr Biomed Engn, New Delhi, India
[2] CSIR, Natl Phys Lab, LF HF Impedance & DC Metrol, New Delhi, India
[3] Indian Inst Technol, Dept Text & Fibre Engn, New Delhi, India
关键词
Blood glucose; Diabetes; Electromagnetic properties; Fetal-bovine serum; Microwave sensor; Sensitivity factor; HYPOGLYCEMIA; SYSTEM;
D O I
10.1080/03772063.2023.2202638
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A microwave sensor with an inter-digitated structure is proposed to estimate non-invasive blood glucose sensing. The proposed sensor is designed, fabricated and measured for the required specifications. The transmission electromagnetic response is investigated to predict the blood-glucose level. Initially, the effectiveness of the fabricated sensor is demonstrated with the help of controlled experiments, performed in fetal-bovine serum sample solutions. A novel multi-parameter-based sensitivity factor is determined to estimate the blood glucose level. The proposed work showed that a multi-parameter approach may be effectively utilized to determine the blood-glucose level non-invasively.
引用
收藏
页码:4203 / 4208
页数:6
相关论文
共 50 条
  • [31] Overcoming Individual Discrepancies, a Learning Model for Non-Invasive Blood Glucose Measurement
    Liu, Weijie
    Huang, Anpeng
    Wan, Ping
    APPLIED SCIENCES-BASEL, 2019, 9 (01):
  • [32] Non-invasive Blood Glucose Measurement Performance Analysis through UWB Imaging
    Ali, Md Shawkat
    Shoumy, N. J.
    Khatun, S.
    Kamarudin, L. M.
    Vijayasarveswari, V.
    2016 3RD INTERNATIONAL CONFERENCE ON ELECTRONIC DESIGN (ICED), 2016, : 513 - 516
  • [33] Non-invasive Blood Glucose Measurement Based on mid-Infrared Spectroscopy
    Chen, Yang
    Liu, Jiang
    Pan, Zhenni
    Shimamoto, Shirgeru
    2020 IEEE 17TH ANNUAL CONSUMER COMMUNICATIONS & NETWORKING CONFERENCE (CCNC 2020), 2020,
  • [34] Non-invasive monitoring of gingival crevicular fluid for estimation of blood glucose level
    M. Yamaguchi
    Y. Kawabata
    S. Kambe
    K. W⇘rdell
    F. H. Nystrom
    K. Naitoh
    H. Yoshida
    Medical and Biological Engineering and Computing, 2004, 42 : 322 - 327
  • [35] On the use of fiber lasers in non-invasive blood glucose monitoring
    Peng, Xi
    Yan, Yi-Xin
    Liu, He
    OPTICAL FIBER TECHNOLOGY, 2022, 68
  • [36] Non-invasive prediction of blood glucose trends during hypoglycemia
    Tronstad, Christian
    Elvebakk, Ole
    Staal, Odd Martin
    Kalvoy, Havard
    Hogetveit, Jan Olav
    Jenssen, Trond Geir
    Birkeland, Kare Inge
    Martinsen, Orjan G.
    ANALYTICA CHIMICA ACTA, 2019, 1052 : 37 - 48
  • [37] Investigation on how to choose measurement sites for non-invasive near-infrared blood glucose sensing
    Jiang, Jingying
    Zou, Da
    Min, Xiaolin
    Ma, Zhenhe
    Xu, Kexin
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS IX, 2012, 8222
  • [38] Voltage Intensity Based Non-Invasive Blood Glucose Monitoring
    Menon, K. A. Unnikrishna
    Hemachandran, Deepak
    Kunnath, Abishek Thekkeyil
    2013 FOURTH INTERNATIONAL CONFERENCE ON COMPUTING, COMMUNICATIONS AND NETWORKING TECHNOLOGIES (ICCCNT), 2013,
  • [39] A Non-Invasive Honey-Cell CSRR Glucose Sensor: Design Considerations and Modelling
    Abdesselam, K.
    Hannachi, C.
    Shahbaz, R.
    Deshours, F.
    Alquie, G.
    Kokabi, H.
    Omer, A.
    Davaine, J. -M
    IRBM, 2023, 44 (01)
  • [40] Evaluation of non-invasive detection of blood glucose using OCT
    Xu Q.-S.
    Feng S.
    Ye D.-T.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2010, 18 (12): : 2688 - 2694