Noninvasive intracranial pressure assessment by optic nerve sheath diameter: Automated measurements as an alternative to clinician-performed measurements

被引:4
|
作者
Netteland, Dag Ferner [1 ,2 ]
Aarhus, Mads [1 ]
Smistad, Erik [3 ]
Sandset, Else Charlotte [4 ,5 ]
Padayachy, Llewellyn [6 ]
Helseth, Eirik [1 ,2 ]
Brekken, Reidar [3 ]
机构
[1] Oslo Univ Hosp Ulleval, Dept Neurosurg, Oslo, Norway
[2] Univ Oslo, Fac Med, Oslo, Norway
[3] SINTEF, Dept Hlth Res, Med Technol, Trondheim, Norway
[4] Oslo Univ Hosp Ulleval, Dept Neurol, Oslo, Norway
[5] Norwegian Air Ambulance Fdn, Oslo, Norway
[6] Univ Pretoria, Steve Biko Acad Hosp, Fac Hlth Sci, Sch Med,Dept Neurosurg, Pretoria, South Africa
来源
FRONTIERS IN NEUROLOGY | 2023年 / 14卷
关键词
optic nerve sheath diameter; ultrasound; intracranial pressure; traumatic brain injury; automated measurements; machine learning;
D O I
10.3389/fneur.2023.1064492
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
IntroductionOptic nerve sheath diameter (ONSD) has shown promise as a noninvasive parameter for estimating intracranial pressure (ICP). In this study, we evaluated a novel automated method of measuring the ONSD in transorbital ultrasound imaging. MethodsFrom adult traumatic brain injury (TBI) patients with invasive ICP monitoring, bedside manual ONSD measurements and ultrasound videos of the optic nerve sheath complex were simultaneously acquired. Automatic ONSD measurements were obtained by the processing of the ultrasound videos by a novel software based on a machine learning approach for segmentation of the optic nerve sheath. Agreement between manual and automated measurements, as well as their correlation to invasive ICP, was evaluated. Furthermore, the ability to distinguish dichotomized ICP for manual and automatic measurements of ONSD was compared, both for ICP dichotomized at >= 20 mmHg and at the 50th percentile (>= 14 mmHg). Finally, we performed an exploratory subgroup analysis based on the software's judgment of optic nerve axis alignment to elucidate the reasons for variation in the agreement between automatic and manual measurements. ResultsA total of 43 ultrasound examinations were performed on 25 adult patients with TBI, resulting in 86 image sequences covering the right and left eyes. The median pairwise difference between automatically and manually measured ONSD was 0.06 mm (IQR -0.44 to 0.38 mm; p = 0.80). The manually measured ONSD showed a positive correlation with ICP, while automatically measured ONSD showed a trend toward, but not a statistically significant correlation with ICP. When examining the ability to distinguish dichotomized ICP, manual and automatic measurements performed with similar accuracy both for an ICP cutoff at 20 mmHg (manual: AUC 0.74, 95% CI 0.58-0.88; automatic: AUC 0.83, 95% CI 0.66-0.93) and for an ICP cutoff at 14 mmHg (manual: AUC 0.70, 95% CI 0.52-0.85; automatic: AUC 0.68, 95% CI 0.48-0.83). In the exploratory subgroup analysis, we found that the agreement between measurements was higher in the subgroup where the automatic software evaluated the optic nerve axis alignment as good as compared to intermediate/poor. ConclusionThe novel automated method of measuring the ONSD on the ultrasound videos using segmentation of the optic nerve sheath showed a reasonable agreement with manual measurements and performed equally well in distinguishing high and low ICP.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Evaluation of Optic Nerve Sheath Diameter and Transcranial Doppler As Noninvasive Tools to Detect Raised Intracranial Pressure in Children
    Sharawat, Indar Kumar
    Kasinathan, Ananthanarayanan
    Bansal, Arun
    Sahu, Jitendra Kumar
    Sodhi, Kushaljit Singh
    Dogra, Mangat Ram
    Sankhyan, Naveen
    PEDIATRIC CRITICAL CARE MEDICINE, 2020, 21 (11) : 959 - 965
  • [42] Ultrasonographic evaluation of the diameter of the optic nerve sheath for medication of intracranial pressure: a case report
    Carrillo Esper, Raul
    Flores Rivera, Oscar Ivan
    Pena Perez, Carlos Alberto
    Carrillo Cordova, Luis Daniel
    Carrillo Cordova, Jorge Raul
    Carrillo Cordova, Carlos Alberto
    Carrillo Cordova, Dulce Maria
    GACETA MEDICA DE MEXICO, 2014, 150 (02): : 165 - 170
  • [43] Sonography for Determining the Optic Nerve Sheath Diameter With Increasing Intracranial Pressure in a Porcine Model
    Hamilton, Douglas R.
    Sargsyan, Ashot E.
    Melton, Shannon L.
    Garcia, Kathleen M.
    Oddo, Bill
    Kwon, David S.
    Feiveson, Alan H.
    Dulchavsky, Scott A.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2011, 30 (05) : 651 - 659
  • [44] Measurement of Optic Nerve Sheath Diameter to Detect Increased Intracranial Pressure in Hypertensive Patients
    Dikmetas, Cesareddin
    Ergin, Mehmet
    Duman, Cigdem Savas
    Gulpembe, Mustafa
    Acar, Tarik
    Yavuz, Kenan
    Cander, Basar
    Girisgin, Sadik
    Kocak, Sedat
    EURASIAN JOURNAL OF EMERGENCY MEDICINE, 2020, 19 (01) : 40 - 45
  • [45] Evaluation of bedside sonographic measurement of optic nerve sheath diameter for assessment of raised intracranial pressure in adult head trauma patients
    Mathews, Alvin
    Cattamanchi, Srihari
    Panneerselvam, Tamilanbu
    Trichur, Ramakrishnan, V
    JOURNAL OF EMERGENCIES TRAUMA AND SHOCK, 2020, 13 (03) : 190 - 195
  • [46] The concordance of optic nerve sheath diameter measurements with the clinical course in children with traumatic head injury
    Kavak, Rasime Pelin
    Ozdemir, Meltem
    Kavak, Nezih
    Ertan, Nurcan
    Kulah, Bahadir
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2020, 26 (05): : 728 - 734
  • [47] Sonographic optic nerve sheath diameter as a surrogate measure for intracranial pressure in anesthetized patients in the Trendelenburg position
    Chin, Ji-Hyun
    Seo, Hyungseok
    Lee, Eun-Ho
    Lee, Joohyun
    Hong, Jun Hyuk
    Hwang, Jai-Hyun
    Kim, Young-Kug
    BMC ANESTHESIOLOGY, 2015, 15
  • [48] Correlation of optic nerve sheath diameter with intracranial pressure monitoring in patients with severe traumatic brain injury
    Sahoo, Siddhartha Shankar
    Agrawal, Deepak
    INDIAN JOURNAL OF NEUROTRAUMA, 2013, 10 (01) : 9 - 12
  • [49] Noninvasive intracranial pressure monitoring via optic nerve sheath diameter for robotic surgery in steep Trendelenburg position
    Shah, Shagun Bhatia
    Bhargava, Ajay Kumar
    Choudhury, Itee
    SAUDI JOURNAL OF ANAESTHESIA, 2015, 9 (03) : 239 - 246
  • [50] Ultrasonographic optic nerve sheath diameter to detect increased intracranial pressure in adults: a meta-analysis
    Kim, Sung-Eun
    Hong, Eun Pyo
    Kim, Heung Cheol
    Lee, Si Un
    Jeon, Jin Pyeong
    ACTA RADIOLOGICA, 2019, 60 (02) : 221 - 229