Noninvasive intracranial pressure assessment by optic nerve sheath diameter: Automated measurements as an alternative to clinician-performed measurements

被引:4
|
作者
Netteland, Dag Ferner [1 ,2 ]
Aarhus, Mads [1 ]
Smistad, Erik [3 ]
Sandset, Else Charlotte [4 ,5 ]
Padayachy, Llewellyn [6 ]
Helseth, Eirik [1 ,2 ]
Brekken, Reidar [3 ]
机构
[1] Oslo Univ Hosp Ulleval, Dept Neurosurg, Oslo, Norway
[2] Univ Oslo, Fac Med, Oslo, Norway
[3] SINTEF, Dept Hlth Res, Med Technol, Trondheim, Norway
[4] Oslo Univ Hosp Ulleval, Dept Neurol, Oslo, Norway
[5] Norwegian Air Ambulance Fdn, Oslo, Norway
[6] Univ Pretoria, Steve Biko Acad Hosp, Fac Hlth Sci, Sch Med,Dept Neurosurg, Pretoria, South Africa
来源
FRONTIERS IN NEUROLOGY | 2023年 / 14卷
关键词
optic nerve sheath diameter; ultrasound; intracranial pressure; traumatic brain injury; automated measurements; machine learning;
D O I
10.3389/fneur.2023.1064492
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
IntroductionOptic nerve sheath diameter (ONSD) has shown promise as a noninvasive parameter for estimating intracranial pressure (ICP). In this study, we evaluated a novel automated method of measuring the ONSD in transorbital ultrasound imaging. MethodsFrom adult traumatic brain injury (TBI) patients with invasive ICP monitoring, bedside manual ONSD measurements and ultrasound videos of the optic nerve sheath complex were simultaneously acquired. Automatic ONSD measurements were obtained by the processing of the ultrasound videos by a novel software based on a machine learning approach for segmentation of the optic nerve sheath. Agreement between manual and automated measurements, as well as their correlation to invasive ICP, was evaluated. Furthermore, the ability to distinguish dichotomized ICP for manual and automatic measurements of ONSD was compared, both for ICP dichotomized at >= 20 mmHg and at the 50th percentile (>= 14 mmHg). Finally, we performed an exploratory subgroup analysis based on the software's judgment of optic nerve axis alignment to elucidate the reasons for variation in the agreement between automatic and manual measurements. ResultsA total of 43 ultrasound examinations were performed on 25 adult patients with TBI, resulting in 86 image sequences covering the right and left eyes. The median pairwise difference between automatically and manually measured ONSD was 0.06 mm (IQR -0.44 to 0.38 mm; p = 0.80). The manually measured ONSD showed a positive correlation with ICP, while automatically measured ONSD showed a trend toward, but not a statistically significant correlation with ICP. When examining the ability to distinguish dichotomized ICP, manual and automatic measurements performed with similar accuracy both for an ICP cutoff at 20 mmHg (manual: AUC 0.74, 95% CI 0.58-0.88; automatic: AUC 0.83, 95% CI 0.66-0.93) and for an ICP cutoff at 14 mmHg (manual: AUC 0.70, 95% CI 0.52-0.85; automatic: AUC 0.68, 95% CI 0.48-0.83). In the exploratory subgroup analysis, we found that the agreement between measurements was higher in the subgroup where the automatic software evaluated the optic nerve axis alignment as good as compared to intermediate/poor. ConclusionThe novel automated method of measuring the ONSD on the ultrasound videos using segmentation of the optic nerve sheath showed a reasonable agreement with manual measurements and performed equally well in distinguishing high and low ICP.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Are ultrasonography measurements of optic nerve sheath diameter an alternative to funduscopy in children with syndromic craniosynostosis? Clinical article
    Driessen, Caroline
    Bannink, Natalja
    Lequin, Maarten
    van Veelen, Marie-Lise C.
    Naus, Nicole C.
    Joosten, Koen F. M.
    Mathijssen, Irene M. J.
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2011, 8 (03) : 329 - 334
  • [32] Effect of Osmotherapy on Optic Nerve Sheath Diameter in Patients with Increased Intracranial Pressure
    Launey, Yoann
    Nesseler, Nicolas
    Le Maguet, Pascale
    Malledant, Yannick
    Seguin, Philippe
    JOURNAL OF NEUROTRAUMA, 2014, 31 (10) : 984 - 988
  • [33] Optic Nerve Sheath Diameter is not Related to Intracranial Pressure in Subarachnoid Hemorrhage Patients
    Zoerle, Tommaso
    Caccioppola, Alessio
    D'Angelo, Eleonora
    Carbonara, Marco
    Conte, Giorgio
    Avignone, Sabrina
    Zanier, Elisa R.
    Birg, Tatiana
    Ortolano, Fabrizio
    Triulzi, Fabio
    Stocchetti, Nino
    NEUROCRITICAL CARE, 2020, 33 (02) : 491 - 498
  • [34] Monitoring of Intracranial Pressure by CT-Defined Optic Nerve Sheath Diameter
    Bekerman, Inessa
    Kimiagar, Itzhak
    Sigal, Tal
    Vaiman, Michael
    JOURNAL OF NEUROIMAGING, 2016, 26 (03) : 309 - 314
  • [35] Ultrasonography Assessments of Optic Nerve Sheath Diameter as a Noninvasive and Dynamic Method of Detecting Changes in Intracranial Pressure
    Wang, Li-juan
    Chen, Li-min
    Chen, Ying
    Bao, Li-yang
    Zheng, Nan-nan
    Wang, Yu-zhi
    Xing, Ying-qi
    JAMA OPHTHALMOLOGY, 2018, 136 (03) : 250 - 256
  • [36] Optic nerve sheath diameter does not correlate with intracranial pressure in pediatric neurocritical care patients
    Austin Biggs
    Marlina Lovett
    Melissa Moore-Clingenpeel
    Nicole O’Brien
    Child's Nervous System, 2021, 37 : 951 - 957
  • [37] Optic Nerve Sheath Measurements by Computed Tomography to Predict Intracranial Pressure and Guide Surgery in Patients with Traumatic Brain Injury
    Liu, Meng
    Yang, Zhi-Kun
    Yan, Yu-Feng
    Shen, Xiao
    Yao, Hui-Bin
    Fei, Li
    Wang, Er-Song
    WORLD NEUROSURGERY, 2020, 134 : E317 - E324
  • [38] Keep an Eye on the Intracranial Pressure, Thanks to the Optic Nerve Sheath Diameter
    Weinmann, Alexandre Vagh
    Beaucreux, Charlotte
    Kearns, Kevin
    Dubost, Clement
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2018, 22 (06) : 460 - 462
  • [39] Optic nerve sheath diameter ultrasonography for elevated intracranial pressure detection
    Wang Li-Juan
    Chen Hong-Xiu
    Chen Ying
    Yu Ze-Yang
    Xing Ying-Qi
    ANNALS OF CLINICAL AND TRANSLATIONAL NEUROLOGY, 2020, 7 (05): : 865 - 868
  • [40] Bedside sonographic measurements of optic nerve sheath diameter in children with diabetic ketoacidosis
    Sik, Nihan
    Erbas, Ibrahim Mert
    Demir, Korcan
    Yilmaz, Durgul
    Duman, Murat
    PEDIATRIC DIABETES, 2021, 22 (04) : 618 - 624