Seismic Retrofitting of Nonseismically Detailed Exterior Reinforced Concrete Beam-Column Joint by Active Confinement Using Shape Memory Alloy Wires

被引:4
|
作者
Suhail, R. [1 ,2 ]
Amato, G. [3 ]
Alam, M. Shahria [4 ]
Broderick, B. [5 ]
Grimes, M. [5 ]
McCrum, D. [6 ]
机构
[1] RMS D&B, Srinagar 190001, Kashmir, India
[2] Queens Univ Belfast, Sch Nat & Built Environm, Belfast BT9 5AG, North Ireland
[3] Queens Univ Belfast, Sch Nat & Built Environm, Belfast BT9 5AG, North Ireland
[4] Univ British Columbia, Fac Appl Sci, Sch Engn, Okanagan Campus, Vancouver, BC V1V 1V7, Canada
[5] Trinity Coll Dublin, Sch Civil Struct & Environm Engn, Dublin, Ireland
[6] Univ Coll Dublin, Sch Civil Engn, Dublin, Ireland
关键词
Seismic retrofitting; Beam-column joint (BCJ); Shape memory alloys (SMAs); Active confinement; Heat-activated prestressing; Fiber reinforced concrete; SHEAR-STRENGTH; TURKEY EARTHQUAKE; AUGUST; 17; BEHAVIOR; PERFORMANCE; DAMAGE; MODEL; KOCAELI; DESIGN; SMA;
D O I
10.1061/JSENDH.STENG-11843
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
It is widely accepted that the seismic retrofitting of nonseismically detailed reinforced concrete beam-column joints (BCJs) in reinforced concrete (RC) frame buildings is an urgent necessity due to its high vulnerability and potential consequences in seismic events. As a result, considerable effort has already been put into developing efficient and practical retrofitting solutions for such BCJs. Most of the existing techniques, however, are based on either passive confinement techniques, for example, fiber reinforced polymer (FRP) wrappings, or involve a considerable joint enlargement, which, in many cases, is undesirable. In this study a new technique of retrofitting BCJs is proposed by employing a more effective method of confinement (i.e., active confinement), utilizing the shape recovery feature of shape memory alloys (SMAs). To evaluate the performance of the proposed retrofitting scheme, experimental tests were conducted on full-scale BCJ specimens. The efficacy of the proposed retrofitting scheme is evaluated in terms of enhancement in strength, ductility, energy dissipation capacity, damage reduction in the specimens, and ease of application. The results from this study suggest that the proposed retrofitting scheme could be effectively used in achieving the full capacity of the joints corresponding to beam yielding and consequently enhances the energy dissipation capacity of the system significantly. The test results demonstrated that the proposed retrofitting scheme performs excellently in reducing the joint shear strain (core damage) (to almost zero or negligible) and also in retaining the full axial load carrying capacity of the column, even at very large drift values. The proposed retrofitted scheme could also be conveniently used in cases where the capacity ratio of column-to-beam needs to be improved.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] Research on seismic design method of a beam-column joint in reinforced concrete space frame
    Cui, Yanwei
    Li, Zhenbao
    Song, Kun
    Ma, Hua
    Tang, Zhenyun
    5TH INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY, ENVIRONMENT AND CHEMICAL ENGINEERING, 2019, 358
  • [43] Numerical investigation of reinforced-concrete beam-column joints retrofitted using external superelastic shape memory alloy bars
    Elbahy, Yamen Ibrahim
    Youssef, Maged A.
    Meshaly, M.
    AIMS MATERIALS SCIENCE, 2021, 8 (05) : 716 - 738
  • [44] Analytical model for predicting sheer strengths of exterior reinforced concrete beam-column joints for seismic resistance
    Hwang, SJ
    Lee, HJ
    ACI STRUCTURAL JOURNAL, 1999, 96 (05) : 846 - 857
  • [45] Interaction of internal forces of exterior beam-column joints of reinforced concrete frames under seismic action
    Zhou, Hua
    Zhang, Zhisheng
    STRUCTURAL ENGINEERING AND MECHANICS, 2012, 44 (02) : 197 - 217
  • [46] Seismic retrofitting of damaged exterior beam-column joints using fibre reinforced plastic composite-steel plate combined technique
    Sasmal, Saptarshi
    Novak, Balthasar
    Ramanjaneyulu, K.
    Srinivas, V.
    Roehm, Constanze
    Lakshmanan, N.
    Iyer, Nagesh R.
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2013, 9 (02) : 116 - 129
  • [47] Seismic performance of RCS beam-column joints using fiber reinforced concrete
    Xuan Huy Nguyen
    Dang Dung Le
    Quang-Huy Nguyen
    Hoang Quan Nguyen
    EARTHQUAKES AND STRUCTURES, 2020, 18 (05) : 599 - 607
  • [48] Experimental Study on Performance of Ductile and Non-ductile Reinforced Concrete Exterior Beam-column Joint
    Ravikumar, S.
    Kothandaraman, S.
    International Journal of Engineering, Transactions B: Applications, 2022, 35 (07): : 1237 - 1245
  • [49] Behavior of sisal fiber-reinforced concrete in exterior beam-column joint under monotonic loading
    Okeola A.A.
    Mwero J.
    Bello A.
    Asian Journal of Civil Engineering, 2021, 22 (4) : 627 - 636
  • [50] APPROXIMATE EQUATION FOR ULTIMATE MOMENT OF REINFORCED CONCRETE EXTERIOR BEAM-COLUMN JOINT WITH BENT BAR ANCHORAGE
    Asuka M.
    Hajime O.
    Kazuhiro M.
    AIJ Journal of Technology and Design, 2024, 30 (75) : 739 - 744