Seismic Retrofitting of Nonseismically Detailed Exterior Reinforced Concrete Beam-Column Joint by Active Confinement Using Shape Memory Alloy Wires

被引:4
|
作者
Suhail, R. [1 ,2 ]
Amato, G. [3 ]
Alam, M. Shahria [4 ]
Broderick, B. [5 ]
Grimes, M. [5 ]
McCrum, D. [6 ]
机构
[1] RMS D&B, Srinagar 190001, Kashmir, India
[2] Queens Univ Belfast, Sch Nat & Built Environm, Belfast BT9 5AG, North Ireland
[3] Queens Univ Belfast, Sch Nat & Built Environm, Belfast BT9 5AG, North Ireland
[4] Univ British Columbia, Fac Appl Sci, Sch Engn, Okanagan Campus, Vancouver, BC V1V 1V7, Canada
[5] Trinity Coll Dublin, Sch Civil Struct & Environm Engn, Dublin, Ireland
[6] Univ Coll Dublin, Sch Civil Engn, Dublin, Ireland
关键词
Seismic retrofitting; Beam-column joint (BCJ); Shape memory alloys (SMAs); Active confinement; Heat-activated prestressing; Fiber reinforced concrete; SHEAR-STRENGTH; TURKEY EARTHQUAKE; AUGUST; 17; BEHAVIOR; PERFORMANCE; DAMAGE; MODEL; KOCAELI; DESIGN; SMA;
D O I
10.1061/JSENDH.STENG-11843
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
It is widely accepted that the seismic retrofitting of nonseismically detailed reinforced concrete beam-column joints (BCJs) in reinforced concrete (RC) frame buildings is an urgent necessity due to its high vulnerability and potential consequences in seismic events. As a result, considerable effort has already been put into developing efficient and practical retrofitting solutions for such BCJs. Most of the existing techniques, however, are based on either passive confinement techniques, for example, fiber reinforced polymer (FRP) wrappings, or involve a considerable joint enlargement, which, in many cases, is undesirable. In this study a new technique of retrofitting BCJs is proposed by employing a more effective method of confinement (i.e., active confinement), utilizing the shape recovery feature of shape memory alloys (SMAs). To evaluate the performance of the proposed retrofitting scheme, experimental tests were conducted on full-scale BCJ specimens. The efficacy of the proposed retrofitting scheme is evaluated in terms of enhancement in strength, ductility, energy dissipation capacity, damage reduction in the specimens, and ease of application. The results from this study suggest that the proposed retrofitting scheme could be effectively used in achieving the full capacity of the joints corresponding to beam yielding and consequently enhances the energy dissipation capacity of the system significantly. The test results demonstrated that the proposed retrofitting scheme performs excellently in reducing the joint shear strain (core damage) (to almost zero or negligible) and also in retaining the full axial load carrying capacity of the column, even at very large drift values. The proposed retrofitted scheme could also be conveniently used in cases where the capacity ratio of column-to-beam needs to be improved.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Retrofitting nonseismically detailed exterior beam-column joints using concrete covers together with CFRP jacket
    Hadi, Muhammad N. S.
    Tung Minh Tran
    CONSTRUCTION AND BUILDING MATERIALS, 2014, 63 : 161 - 173
  • [2] Seismic behaviour of repaired superelastic shape memory alloy reinforced concrete beam-column joint
    Nehdi, Moncef
    Alam, M. Shahria
    Youssef, Maged A.
    SMART STRUCTURES AND SYSTEMS, 2011, 7 (05) : 329 - 348
  • [3] Effect of confinement on the seismic performance of reinforced concrete exterior beam-column joints
    Asha, P.
    Sundararajan, R.
    AUSTRALIAN JOURNAL OF STRUCTURAL ENGINEERING, 2018, 19 (01) : 59 - 66
  • [4] Behavior of exterior concrete beam-column joints reinforced with Shape Memory Alloy (SMA) bars
    Azariani, Hossein Rezaee
    Esfahani, M. Reza
    Shariatmadar, Hashem
    STEEL AND COMPOSITE STRUCTURES, 2018, 28 (01): : 83 - 98
  • [5] Seismic performance of exterior reinforced concrete beam-column joint with corroded reinforcement
    Zhang, Xinchen
    Li, Bing
    ENGINEERING STRUCTURES, 2021, 228
  • [6] Ultimate moment of reinforced concrete exterior beam-column joint
    Kusuhara, Fumio
    Shiohara, Hitoshi
    Journal of Structural and Construction Engineering, 2013, 78 (693): : 1949 - 1958
  • [7] Numerical seismic performance evaluation of concrete beam-column joint reinforced with different super elastic shape memory alloy rebars
    Nahar, Mumtasirun
    Billah, A. H. M. Muntasir
    Kamal, Habibur R.
    Islam, Kamrul
    ENGINEERING STRUCTURES, 2019, 194 : 161 - 172
  • [8] Seismic Performance of Lightly Reinforced Concrete Exterior Beam-Column Joints
    Meas, Kimreth
    Li, Bing
    Imran, Iswandi
    ADVANCES IN STRUCTURAL ENGINEERING, 2012, 15 (10) : 1765 - 1780
  • [9] Seismic Behavior of Reinforced Concrete Exterior Wide Beam-Column Joints
    Li, Bing
    Kulkarni, Sudhakar A.
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2010, 136 (01): : 26 - 36
  • [10] A Novel Reinforcement Pattern for Exterior Reinforced Concrete Beam-Column Joint
    Kularni, S. M.
    Patil, Y. D.
    CHEMICAL, CIVIL AND MECHANICAL ENGINEERING TRACKS OF 3RD NIRMA UNIVERSITY INTERNATIONAL CONFERENCE ON ENGINEERING (NUICONE2012), 2013, 51 : 184 - 193