A combined experimental-modeling approach for turbidity removal optimization in a coagulation-flocculation unit of a drinking water treatment plant

被引:13
作者
Chiavola, Agostina [1 ]
Di Marcantonio, Camilla [1 ]
D'Agostini, Martina [1 ]
Leoni, Simone [2 ]
Lazzazzara, Marco [2 ]
机构
[1] Sapienza Univ Rome, Dept Civil Bldg & Environm Engn DICEA, Via Eudossiana 18, I-00184 Rome, Italy
[2] ACEA ELABORI SpA, Via Vitorchiano 165, Rome, Italy
关键词
Coagulant; Coagulation-flocculation; Drinking water treatment plant; Elbow method; k-means; Turbidity;
D O I
10.1016/j.jprocont.2023.103068
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The drinking water treatment plant plays a key role in providing the consumers with a safe water, in compliance with the United Nations Sustainable Development Goal n. 6 (Clean water and sanitation). The typical drinking water treatment plant includes: coagulation-flocculation, sedimentation, filtration and disinfection. Turbidity removal is among the more common pollutants to remove; this goal is mainly achieved by the coagulation-flocculation process. The present paper shows the results of the application of a combined experimental-modeling approach for turbidity removal optimization in a coagulation-flocculation unit of a full-scale drinking water treatment plant. The applied approach consisted of a laboratory experimental activity aimed at determining the best coagulant type and dosage. Among the different chemicals tested, Poly aluminum chloride (PAC) provided the highest removal at the lowest dosage (90% at 3.5 mg/L PAC, 88% at 18.9 mg/L PACS and 77% at 30 mg/L FeCl3). The addition of polyelectrolytes did not improve the removal at such a level to justify the consequent increase of the costs. Based on the findings of this phase of the study, a data-driven model was implemented using as input variables the historical data of influent and effluent turbidity and influent flow rate. Combining regression models and statistical analysis, it was possible to build up an algorithm for the case-study plant allowing to select the PAC dosage to apply as a function of the influent turbidity, to ensure the constant compliance with the regulation limit on effluent turbidity. & COPY; 2023 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页数:10
相关论文
共 23 条
[1]  
[Anonymous], 2023, Decreto Legislativo
[2]  
APAT IRSA-CNR, 2003, Analytical methods for water 29/2003
[3]  
APHA, 2017, Standard Methods for Examination of Water and Wastewater, American Public Health Association, AWWA, WEF, V22nd
[4]   Use of Aloe vera as an Organic Coagulant for Improving Drinking Water Quality [J].
Benalia, Abderrezzaq ;
Derbal, Kerroum ;
Khalfaoui, Amel ;
Bouchareb, Raouf ;
Panico, Antonio ;
Gisonni, Corrado ;
Crispino, Gaetano ;
Pirozzi, Francesco ;
Pizzi, Antonio .
WATER, 2021, 13 (15)
[5]   Use of Acorn Leaves as a Natural Coagulant in a Drinking Water Treatment Plant [J].
Benalia, Abderrezzaq ;
Derbal, Kerroum ;
Panico, Antonio ;
Pirozzi, Francesco .
WATER, 2019, 11 (01)
[6]  
Benefield L.D., 1982, PROCESS CHEM WATER W
[7]  
Bratby, 1980, Coagulation and Flocculation with an Emphasis on Water and Wastewater Treatment
[8]  
Droste R., 2018, THEORY PRACTICE WATE, V2nd
[9]  
Edzwald J.K., 2011, WATER QUALITY TREATM
[10]   Optimum coagulant forecasting by modeling jar test experiments using ANNs [J].
Haghiri, Sadaf ;
Daghighi, Amin ;
Moharramzadeh, Sina .
Drinking Water Engineering and Science, 2018, 11 (01) :1-8