Transradial access with Simmons guiding catheter for carotid artery stenting: Feasibility and procedural complications in a single-center experience

被引:2
作者
Muszynski, P. [1 ]
Richard, S. [2 ,3 ]
Finitsis, S. [4 ]
Humbertjean, L. [3 ]
Audibert, G. [5 ]
Mione, G. [3 ]
Harsan, O. [1 ]
Derelle, A. L. [1 ]
Liao, L. [1 ,2 ]
Zhu, F. [1 ,2 ]
Olivot, J. M. [6 ]
Anxionnat, R. [1 ,2 ]
Calvet, D. [7 ]
Gory, Benjamin [1 ,2 ,8 ]
机构
[1] CHRU Nancy, Dept Diagnost & Therapeut Neuroradiol, Nancy, France
[2] Univ Lorraine, Nancy, France
[3] CHRU Nancy, Dept Neurol, Stroke Unit, Nancy, France
[4] Univ Gen Hosp Thessaloniki AHEPA, Neuroradiolol, Thessaloniki, Greece
[5] CHRU Nancy, Dept Intens Care Unit, Nancy, France
[6] Univ Toulouse, Hop Pierre Paul Riquet, CHU Toulouse, Dept Neurol Neuroradiol & Pathol,Toulouse Neuroima, Toulouse, France
[7] Hop Sainte Anne, Neurol & Neurovasc unit, GHU Psychiat & Neurosci, Paris, France
[8] CHRU Nancy, Hop Cent, Dept Diagnost & Therapeut Neuroradiol, 29 Ave Marechal Lattre Tassigny, F-54035 Nancy, France
关键词
Carotid artery stenting; radial approach; interventional neuroradiology;
D O I
10.1177/15910199231171845
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background There is an increasing number of transradial approach (TRA) for carotid artery stenting (CAS), however, similar techniques and materials as for femoral access are used. We report the results of TRA lower profile technique for CAS using a 7 F Simmons guiding catheter, especially in terms of feasibility and procedural safety in a single center. Materials and Methods We retrospectively analyzed 68 consecutive patients with symptomatic extracranial carotid stenoses who underwent 75 CAS between January 2018 and December 2021. The success and crossover rate, procedural time, fluoroscopy, clinical outcomes, technical considerations, and procedural complications were analyzed. Results TRA CAS with Simmons guiding catheter was successful in 67/75 (89.3%) cases, with a 7 (9.3%) crossover rate. Fluoroscopy mean time was 15.8 minutes. Two forearm hematomas were described. No ischemic or surgical site complications were reported. Conclusions In our experience frontline TRA with a 7 F Simmons guiding catheter is feasible with high procedural success and a low rate of access site complications.
引用
收藏
页数:6
相关论文
共 31 条
  • [11] Comparison of dual protection and distal filter protection as a distal embolic protection method during carotid artery stenting: a single-center carotid artery stenting experience
    Kajihara, Yosuke
    Sakamoto, Shigeyuki
    Kiura, Yoshihiro
    Mukada, Kazutoshi
    Chaki, Takahiro
    Kajihara, Shiro
    Kurisu, Kaoru
    NEUROSURGICAL REVIEW, 2015, 38 (04) : 671 - 676
  • [12] The impact of post-dilatation on periprocedural outcomes during carotid artery stenting: A single-center experience
    Besli, Feyzullah
    Gungoren, Fatih
    Kocaturk, Ozcan
    Tanriverdi, Zulkif
    Tascanov, Mustafa Begenc
    ATHEROSCLEROSIS, 2019, 290 : 74 - 79
  • [13] Comparison of dual protection and distal filter protection as a distal embolic protection method during carotid artery stenting: a single-center carotid artery stenting experience
    Yosuke Kajihara
    Shigeyuki Sakamoto
    Yoshihiro Kiura
    Kazutoshi Mukada
    Takahiro Chaki
    Shiro Kajihara
    Kaoru Kurisu
    Neurosurgical Review, 2015, 38 : 671 - 676
  • [14] Carotid artery stenting with distal filter protection: single-center experience in high-surgical-risk patients
    Rainer Knur
    Heart and Vessels, 2011, 26 : 125 - 130
  • [15] Results of carotid stenting in patients with contralateral internal carotid artery occlusion: a retrospective single-center analysis and 22 years of experience
    Esra Kochan Kizilkilic
    Yeşim Namdar Akan
    Baran Atbas
    Seyfullah Halit Karagöz
    Bora Korkmazer
    Serdar Arslan
    Civan Islak
    Naci Kocer
    Osman Kizilkilic
    Neuroradiology, 2025, 67 (2) : 393 - 401
  • [16] Carotid artery stenting with distal filter protection: single-center experience in high-surgical-risk patients
    Knur, Rainer
    HEART AND VESSELS, 2011, 26 (02) : 125 - 130
  • [17] Carotid artery stenting with distal protection using the carotid wallstent and FilterWire neuroprotection: Single-center experience of 380 cases with midterm outcomes
    Lin, Peter H.
    Zhou, Wei
    Guerrero, Marlon A.
    McCoy, Sally A.
    Felkaz, Deborah
    Kougias, Panos
    El Sayed, Hosam F.
    VASCULAR, 2006, 14 (05) : 237 - 244
  • [18] The safety and efficacy of the Mo.Ma system device for carotid artery stenting: A single-center experience from Taiwan
    Cheng, Cheng-Chung
    Lin, Chin-Sheng
    Yin, Wei-Hsian
    Lin, Chin
    Liu, I-Fan
    Lee, Yu-Feng
    Liu, Wei-Ting
    Fu, Hao-Neng
    Huang, Chien-Lung
    Tsao, Tien-Ping
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [19] Simultaneous Carotid Artery Stenting and Coronary Artery Bypass Grafting in Urgent Patients: A Single Center Experience
    Fiorentino, Mariafrancesca
    Mikus, Elisa
    Nerla, Roberto
    Sangiorgi, Diego
    Ruggiero, Andrea
    Tripodi, Alberto
    Castriota, Fausto
    Savini, Carlo
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (23)
  • [20] Predictors of periprocedural complications of carotid artery stenting - a multivariate analysis of a single-centre experience
    Vatan, Mehmet Bulent
    Acar, Bilgehan Atilgan
    Aksoy, Murat
    Can, Yusuf
    Varim, Ceyhun
    Agac, Mustafa Tarik
    Kilic, Harun
    Tatli, Ersan
    Gunduz, Huseyin
    Akdemir, Ramazan
    VASA-EUROPEAN JOURNAL OF VASCULAR MEDICINE, 2016, 45 (05) : 387 - 393