Design of a Novel Haptic Joystick for the Teleoperation of Continuum-Mechanism-Based Medical Robots

被引:7
作者
Xie, Yiping [1 ,2 ]
Hou, Xilong [3 ]
Wang, Shuangyi [2 ,3 ]
机构
[1] Univ Chinese Acad Sci, Sch Artificial Intelligence, Beijing 101408, Peoples R China
[2] Chinese Acad Sci, Inst Automat, State Key Lab Multimodal Artificial Intelligence S, Beijing 100190, Peoples R China
[3] Chinese Acad Sci, Hong Kong Inst Sci & Innovat, Ctr Artificial Intelligence & Robot, Hong Kong 999077, Peoples R China
基金
中国国家自然科学基金;
关键词
haptic device; gravity compensation; continuum robot; teleoperation; variable impedance control; MR ACTUATOR; CLUTCHES; DEVICE; SYSTEM;
D O I
10.3390/robotics12020052
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
Continuum robots are increasingly used in medical applications and the master-slave-based architectures are still the most important mode of operation in human-machine interaction. However, the existing master control devices are not fully suitable for either the mechanical mechanism or the control method. This study proposes a brand-new, four-degree-of-freedom haptic joystick whose main control stick could rotate around a fixed point. The rotational inertia is reduced by mounting all powertrain components on the base plane. Based on the design, kinematic and static models are proposed for position perception and force output analysis, while at the same time gravity compensation is also performed to calibrate the system. Using a continuum-mechanism-based trans-esophageal ultrasound robot as the test platform, a master-slave teleoperation scheme with position-velocity mapping and variable impedance control is proposed to integrate the speed regulation on the master side and the force perception on the slave side. The experimental results show that the main accuracy of the design is within 1.6 degrees. The workspace of the control sticks is -60 degrees to 110 degrees in pitch angle, -40 degrees to 40 degrees in yaw angle, -180 degrees to 180 degrees in roll angle, and -90 degrees to 90 degrees in translation angle. The standard deviation of force output is within 8% of the full range, and the mean absolute error is 1.36 degrees/s for speed control and 0.055 N for force feedback. Based on this evidence, it is believed that the proposed haptic joystick is a good addition to the existing work in the field with well-developed and effective features to enable the teleoperation of continuum robots for medical applications.
引用
收藏
页数:15
相关论文
共 28 条
  • [1] Haptic Device Using a Newly Developed Redundant Parallel Mechanism
    Arata, Jumpei
    Kondo, Hiroyuki
    Ikedo, Norio
    Fujimoto, Hideo
    [J]. IEEE TRANSACTIONS ON ROBOTICS, 2011, 27 (02) : 201 - 214
  • [2] Assessment of a flexible robotic system for endoluminal applications and transanal total mesorectal excision (taTME): Could this be the solution we have been searching for?
    Atallah, S.
    [J]. TECHNIQUES IN COLOPROCTOLOGY, 2017, 21 (10) : 809 - 814
  • [3] Back J, 2017, FRONT ROBOT AI, V4, DOI 10.3389/frobt.2017.00017
  • [4] Bae B, 2001, IROS 2001: PROCEEDINGS OF THE 2001 IEEE/RJS INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, VOLS 1-4, P1738, DOI 10.1109/IROS.2001.977229
  • [5] A Review of Algorithms for Compliant Control of Stiff and Fixed-Compliance Robots
    Calanca, Andrea
    Muradore, Riccardo
    Fiorini, Paolo
    [J]. IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2016, 21 (02) : 613 - 624
  • [6] Development of a Multidirectional Controlled Small-Scale Spherical MR Actuator for Haptic Applications
    Chen, Dapeng
    Song, Aiguo
    Tian, Lei
    Ouyang, Qiangqiang
    Xiong, Pengwen
    [J]. IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2019, 24 (04) : 1597 - 1607
  • [7] Continuum Robots for Medical Interventions
    Dupont, Pierre E.
    Simaan, Nabil
    Choset, Howie
    Rucker, Caleb
    [J]. PROCEEDINGS OF THE IEEE, 2022, 110 (07) : 847 - 870
  • [8] Development and experiments of a continuum robotic system for transoral laryngeal surgery
    Feng, Fan
    Zhou, Yuan
    Hong, Wuzhou
    Li, KeYong
    Xie, Le
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2022, 17 (03) : 497 - 505
  • [9] Design of multi-degree motion haptic mechanisms using smart fluid-based devices
    Han, Young-Min
    Oh, Jong-Seok
    Kim, Soomin
    Choi, Seung-Bok
    [J]. MECHANICS BASED DESIGN OF STRUCTURES AND MACHINES, 2017, 45 (01) : 135 - 144
  • [10] Development of a Novel Gastrointestinal Endoscopic Robot Enabling Complete Remote Control of All Operations: Endoscopic Therapeutic Robot System (ETRS)
    Kume, Keiichiro
    Sakai, Nobuo
    Ueda, Toru
    [J]. GASTROENTEROLOGY RESEARCH AND PRACTICE, 2019, 2019