Intraparenchymal and Subarachnoid Hemorrhage in Stereotactic Electroencephalography Caused by Indirect Adjacent Arterial Injury: Illustrative Case

被引:3
作者
Kawashima, Toshiyuki [1 ]
Uda, Takehiro [1 ]
Koh, Saya [1 ]
Yindeedej, Vich [1 ,2 ]
Ishino, Noboru [1 ]
Ichinose, Tsutomu [1 ]
Arima, Hironori [1 ]
Sakuma, Satoru [3 ]
Goto, Takeo [1 ]
机构
[1] Osaka Metropolitan Univ, Grad Sch Med, Dept Neurosurg, Osaka 5458585, Japan
[2] Thammasat Univ, Thammasat Univ Hosp, Fac Med, Dept Surg,Div Neurosurg, Pathum Thani 12120, Thailand
[3] Osaka Metropolitan Univ, Grad Sch Med, Dept Pediat, Osaka 5458585, Japan
关键词
stereotactic electroencephalography; hemorrhagic complication; intraparenchymal hemorrhage; arachnoid trabeculae; pseudoaneurysm; IMPLANTATION; ELECTRODES; SAFETY; SEEG;
D O I
10.3390/brainsci13030440
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The complication rate of stereotactic electroencephalography (SEEG) is generally low, but various types of postoperative hemorrhage have been reported. We presented an unusual hemorrhagic complication after SEEG placement. A 20-year-old man presented with suspected frontal lobe epilepsy. We implanted 11 SEEG electrodes in the bilateral frontal lobes and the left insula. Computed tomography after implantation showed intraparenchymal hemorrhage in the left temporal lobe and insula and subarachnoid hemorrhage in the left Sylvian cistern. Later, the point of vessel injury was revealed from the identification of a pseudoaneurysm, but this location was not along the planned or actual electrode trajectory. The cause of hemorrhage was suggested to be indirect injury from stretching of the arachnoid trabeculae by the puncture needle.
引用
收藏
页数:8
相关论文
共 12 条
  • [1] Safety and usefulness of insular depth electrodes implanted via an oblique approach in patients with epilepsy
    Afif, Afif
    Chabardes, Stephan
    Minotti, Lorella
    Kahane, Philippe
    Hoffmann, Dominique
    [J]. NEUROSURGERY, 2008, 62 (05) : 471 - 479
  • [2] Indications, technique, and safety profile of insular stereoelectroencephalography electrode implantation in medically intractable epilepsy
    Alomar, Soha
    Mullin, Jeffrey P.
    Smithason, Saksith
    Gonzalez-Martinez, Jorge
    [J]. JOURNAL OF NEUROSURGERY, 2018, 128 (04) : 1147 - 1157
  • [3] Implantation of Stereoelectroencephalography Electrodes: A Systematic Review
    Cardinale, Francesco
    Casaceli, Giuseppe
    Raneri, Fabio
    Miller, Jonathan
    Lo Russo, Giorgio
    [J]. JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2016, 33 (06) : 490 - 502
  • [4] French guidelines on stereoelectroencephalography (SEEG)
    Isnard, Jean
    Taussig, Delphine
    Bartolomei, Fabrice
    Bourdillon, Pierre
    Catenoix, Helene
    Chassoux, Francine
    Chipaux, Mathilde
    Clemenceau, Stephane
    Colnat-Coulbois, Sophie
    Denuelle, Marie
    Derrey, Stephane
    Devaux, Bertrand
    Dorfmueller, Georg
    Gilard, Vianney
    Guenot, Marc
    Job-Chapron, Anne-Sophie
    Landre, Elisabeth
    Lebas, Axel
    Maillard, Louis
    McGonigal, Aileen
    Minotti, Lorella
    Montavont, Alexandra
    Navarro, Vincent
    Nica, Anca
    Reyns, Nicolas
    Scholly, Julia
    Sol, Jean-Christophe
    Szurhaj, William
    Trebuchon, Agnes
    Tyvaert, Louise
    Valenti-Hirsch, Maria Paola
    Valton, Luc
    Vignal, Jean-Pierre
    Sauleau, Paul
    [J]. NEUROPHYSIOLOGIE CLINIQUE-CLINICAL NEUROPHYSIOLOGY, 2018, 48 (01): : 5 - 13
  • [5] Variation in pediatric stereoelectroencephalography practice among pediatric neurosurgeons in the United States: survey results
    Kennedy, Benjamin C.
    Katz, Joshua
    Lepard, Jacob
    Blount, Jeffrey P.
    [J]. JOURNAL OF NEUROSURGERY-PEDIATRICS, 2021, 28 (02) : 212 - 220
  • [6] Technical Aspects of SEEG and Its Interpretation in the Delineation of the Epileptogenic Zone
    Khoo, Hui Ming
    Hall, Jeffery A.
    Dubeau, Francois
    Tani, Naoki
    Oshino, Satoru
    Fujita, Yuya
    Gotman, Jean
    Kishima, Haruhiko
    [J]. NEUROLOGIA MEDICO-CHIRURGICA, 2020, 60 (12) : 565 - 580
  • [7] Primary Experiences with Robot-assisted Navigation-based Frameless Stereo-electroencephalography: Higher Accuracy than Neuronavigation-guided Manual Adjustment
    Kojima, Yuichiro
    Uda, Takehiro
    Kawashima, Toshiyuki
    Koh, Saya
    Hattori, Masato
    Mito, Yuki
    Kunihiro, Noritsugu
    Ikeda, Shohei
    Umaba, Ryoko
    Goto, Takeo
    [J]. NEUROLOGIA MEDICO-CHIRURGICA, 2022, 62 (08) : 361 - 368
  • [8] Frame-based and robot-assisted insular stereo-electroencephalography via an anterior or posterior oblique approach
    Machetanz, Kathrin
    Grimm, Florian
    Wuttke, Thomas, V
    Kegele, Josua
    Lerche, Holger
    Tatagiba, Marcos
    Rona, Sabine
    Gharabaghi, Alireza
    Honegger, Juergen
    Naros, Georgios
    [J]. JOURNAL OF NEUROSURGERY, 2021, 135 (05) : 1477 - 1486
  • [9] Risk analysis of hemorrhage in stereo-electroencephalography procedures
    McGovern, Robert A.
    Ruggieri, Paul
    Bulacio, Juan
    Najm, Imad
    Bingaman, William E.
    Gonzalez-Martinez, Jorge A.
    [J]. EPILEPSIA, 2019, 60 (03) : 571 - 580
  • [10] Is SEEG safe? A systematic review and meta-analysis of stereo-electroencephalography-related complications
    Mullin, Jeffrey P.
    Shriver, Michael
    Alomar, Soha
    Najm, Imad
    Bulacio, Juan
    Chauvel, Patrick
    Gonzalez-Martinez, Jorge
    [J]. EPILEPSIA, 2016, 57 (03) : 386 - 401