Overall performance investigation of a CdTe double-skin ventilated facade integrated with a thermal catalytic air-type PV/T in heating and cooling seasons

被引:1
作者
Zhang, Chengyan [1 ]
Ji, Jie [1 ]
Tang, Yayun [1 ]
Ke, Wei [1 ]
机构
[1] Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, Hefei 230026, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
PV double-skin ventilated facade; Thermal catalytic oxidation; CdTe cells; Air-type PV/T; Building energy-saving; TROMBE WALL; WINDOW; FORMALDEHYDE; SYSTEM; VALIDATION; COLLECTOR; ENERGY;
D O I
10.1016/j.energy.2024.130488
中图分类号
O414.1 [热力学];
学科分类号
摘要
To reduce building energy consumption and improve indoor air quality, this paper proposes a CdTe PV doubleskin ventilated facade integrated with a thermal-catalytic air type PV/T (PV-DSF-TCPV/T). The mathematical model of the proposed system was developed and validated against the experimental data. The daily and seasonal overall performances of the proposed system, including the electrical, thermal, and formaldehyde degradation performances, were studied and compared with that of a conventional PV-DSF. Moreover, parametric analysis was conducted. The main results are: (1) The annual electricity outputs of the proposed system and the conventional system were 414.88 kWh and 105.88 kWh, respectively. (2) Compared with the conventional PV-DSF, the heating and cooling loads of the proposed system decreased by 10.85 % and 34.86 %, respectively, due to the reduction of indoor heat gain in summers and the increase of it in winters. (3) The daily formaldehyde conversion ratio and CADR were 30.84 % and 67.86 m3/h (4) The volumetric flow rate and the cell coverage of the PV-DSF both exerted obvious impacts on the proposed system.
引用
收藏
页数:18
相关论文
共 41 条
  • [21] Solar energy system for heating and domestic hot water supply by means of a heat pump coupled to a photovoltaic ventilated facade
    Martin-Escudero, K.
    Salazar-Herran, E.
    Campos-Celador, A.
    Diarce-Belloso, G.
    Gomez-Arriaran, I.
    [J]. SOLAR ENERGY, 2019, 183 : 453 - 462
  • [22] Formaldehyde Exposure and Asthma in Children: A Systematic Review
    McGwin, Gerald, Jr.
    Lienert, Jeffrey
    Kennedy, John I., Jr.
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 2010, 118 (03) : 313 - 317
  • [23] Cooling potential of ventilated PV facade and solar air heaters combined with a desiccant cooling machine
    Mei, L
    Infield, D
    Eicker, U
    Loveday, D
    Fux, V
    [J]. RENEWABLE ENERGY, 2006, 31 (08) : 1265 - 1278
  • [24] Performance study and parametric analysis of a novel heat pipe PV/T system
    Pei Gang
    Fu Huide
    Zhu Huijuan
    Ji Jie
    [J]. ENERGY, 2012, 37 (01) : 384 - 395
  • [25] Optimized finned absorber geometries for solar air heating collectors
    Pottler, K
    Sippel, CM
    Beck, A
    Fricke, J
    [J]. SOLAR ENERGY, 1999, 67 (1-3) : 35 - 52
  • [26] Performance evaluation of photovoltaic double-skin facade with forced ventilation in the composite climate
    Preet, Sajan
    Sharma, Manoj Kumar
    Mathur, Jyotirmay
    Chowdhury, Amartya
    Mathur, Sanjay
    [J]. JOURNAL OF BUILDING ENGINEERING, 2020, 32
  • [27] Qiu S, 2023, Energy and Built Environment
  • [28] Formaldehyde in the Indoor Environment
    Salthammer, Tunga
    Mentese, Sibel
    Marutzky, Rainer
    [J]. CHEMICAL REVIEWS, 2010, 110 (04) : 2536 - 2572
  • [29] CORRELATION FOR LAMINAR HYDRODYNAMIC ENTRY LENGTH SOLUTIONS FOR CIRCULAR AND NONCIRCULAR DUCTS
    SHAH, RK
    [J]. JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1978, 100 (02): : 177 - 179
  • [30] On the temperature dependence of photovoltaic module electrical performance: A review of efficiency/power correlations
    Skoplaki, E.
    Palyvos, J. A.
    [J]. SOLAR ENERGY, 2009, 83 (05) : 614 - 624