FPGA-Based Decision Support System for ECG Analysis

被引:7
作者
Giorgio, Agostino [1 ]
Guaragnella, Cataldo [1 ]
Rizzi, Maria [1 ]
机构
[1] Politecn Bari, Dipartimento Ingn Elettr & Informaz, via E Orabona 4, I-70125 Bari, Italy
关键词
FPGA; embedded systems; digital signal processing; Matlab; decision support systems (DSS); ECG; arrhythmia; pulmonary embolism risk; QT-segment lengthening; computer-aided detection (CAD); QRS DETECTION; TIME; ACCURACY; SIGNAL;
D O I
10.3390/jlpea13010006
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The high mortality rate associated with cardiac abnormalities highlights the need of accurately detecting heart disorders in the early stage so to avoid severe health consequence for patients. Health trackers have become popular in the form of wearable devices. They are aimed to perform cardiac monitoring outside of medical clinics during peoples' daily lives. Our paper proposes a new diagnostic algorithm and its implementation adopting a FPGA-based design. The conceived system automatically detects the most common arrhythmias and is also able to evaluate QT-segment lengthening and pulmonary embolism risk often caused by myocarditis. Debug and simulations have been carried out firstly in Matlab environment and then in Quartus IDE by Intel. The hardware implementation of the embedded system and the test for the functional accuracy verification have been performed adopting the DE1_SoC development board by Terasic, which is equipped with the Cyclone V 5CSEMA5F31C6 FPGA by Intel. Properly modified real ECG signals corrupted by a mixture of muscle noise, electrode movement artifacts, and baseline wander are used as a test bench. A value of 99.20% accuracy is achieved by taking into account 0.02 mV for the root mean square value of noise voltage. The implemented low-power circuit is suitable as a wearable decision support device.
引用
收藏
页数:24
相关论文
共 62 条
[1]  
AAMI ECAR, 1987, RECOMMENDED PRACTICE
[2]  
academia, FPGA DES VER SYSTEMV
[3]  
Al-Ani MS, 2018, UHD Journal of Science and Technology, V2, P7, DOI [10.21928/uhdjst.v2n2y2018.pp7-14, 10.21928/uhdjst.v2n2y2018.pp7-14, DOI 10.21928/UHDJST.V2N2Y2018.PP7-14]
[4]  
[Anonymous], About Us
[5]  
[Anonymous], 2012, ANSI/AAMI EC57, DOI 10.2345/9781570204784.ch1
[6]   ECG signal denoising by discrete wavelet transform [J].
Aqil M. ;
Jbari A. ;
Bourouhou A. .
International Journal of Online Engineering, 2017, 13 (09) :51-68
[7]   Fusion of ECG and ABP signals based on wavelet transform for cardiac arrhythmias classification [J].
Arvanaghi, Roghayyeh ;
Daneshvar, Sabalan ;
Seyedarabi, Hadi ;
Goshvarpour, Atefeh .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2017, 151 :71-78
[8]  
Baratloo A, 2015, EMERGENCY, V3, P48
[9]   A Survey on Vital Signs Detection Using Radar Techniques and Processing With FPGA Implementation [J].
Bin Obadi, Ameen ;
Soh, Ping Jack ;
Aldayel, Omar ;
Al-Doori, Muataz Hameed ;
Mercuri, Marco ;
Schreurs, Dominique .
IEEE CIRCUITS AND SYSTEMS MAGAZINE, 2021, 21 (01) :41-74
[10]  
Bousseljot R., 1995, NUTZUNG EKG SIGNALDA, V40, P317, DOI 10.1515/bmte.1995.40.s1.317