Electrochemical evaluation and voltammetric determination of some phenolic acids on the boron-doped diamond electrode

被引:3
作者
Sordon, Wanda [1 ]
Jakubowska, Gorzata [1 ]
机构
[1] AGH Univ Sci & Technol, Fac Mat Sci & Ceram, Mickiewicza 30, PL-30059 Krakow, Poland
关键词
BDDE; Phenolic acids; Ammonium citrate buffer; DPV; CAFFEIC ACID; FERULIC ACID; PAPER-CHROMATOGRAPHY; OXIDATIVE STRESS; SENSITIVE DETECTION; GAS-CHROMATOGRAPHY; ANTIOXIDANTS; BEHAVIOR; SAMPLES; EXTRACTION;
D O I
10.1016/j.diamond.2023.110236
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A simple, sensitive, and rapid method of determining phenolic acids, i.e. caffeic, ferulic, syringic, and vanillic using boron-doped diamond electrode (BDDE) by differential pulse voltammetry (DPV) was described. To the best of our knowledge, this is the first presentation of an electrochemical method to determine these compounds on BDDE. Under the conditions presented, the mentioned analytes undergo irreversible oxidation controlled by diffusion. The measurement conditions and composition of the supporting electrolyte were developed and optimized. Optimal measurement parameters ensure the usage of 0.02 mol L (-1) ammonium citrate buffer pH 3.0 as a supporting electrolyte. The calibration graphs were linear with a correlation coefficient (r) >0.9959. The detection limits for the phenolic acids were within 0.01-0.03 mg L (-1). Repeatability in all experiments, expressed by RSD%, was better than 5 %. The influence of interfering metal ions, such as Bi3+, Cd2+, Cu2+, Pb2+ and Tl+, was studied. The proposed method was successfully verified by measuring recoveries of phenolic acids in the model wine solution. The standard addition method was also applied in the determination of syringic acid in homemade and commercially available products: walnuts, walnut tincture, fresh and dried thyme. Effective application of the described analytical approach with the usage of BDDE not only enables the electrochemical detection of these four phenolic acids but also helps to reduce operational costs.
引用
收藏
页数:10
相关论文
共 88 条
[1]   Voltammetric Determination of Ferulic Acid Using Polypyrrole-Multiwalled Carbon Nanotubes Modified Electrode with Sample Application [J].
Abdel-Hamid, Refat ;
Newair, Emad F. .
NANOMATERIALS, 2015, 5 (04) :1704-1715
[2]   Utilizing epicatechin voltammetric oxidation signal for the estimation of total phenolic content in the tea samples via the unmodified boron-doped diamond electrode surface [J].
Ali, Hoshyar Saadi ;
Barzani, Hemn A. H. ;
Yardim, Yavuz .
MICROCHEMICAL JOURNAL, 2023, 189
[3]  
Andrade L.S., 2011, Synthetic Diamond Films, DOI [10.1002/9781118062364.ch8, DOI 10.1002/9781118062364.CH8, DOI 10.1016/J.ELECTACTA.2005.12.039]
[4]   Influence of sonication treatments and extraction solvents on the phenolics and antioxidants in star fruits [J].
Annegowda, H. V. ;
Bhat, Rajeev ;
Min-Tze, Liong ;
Karim, A. A. ;
Mansor, S. M. .
JOURNAL OF FOOD SCIENCE AND TECHNOLOGY-MYSORE, 2012, 49 (04) :510-514
[5]  
AOAC, 2016, Appendix F: Guidelines for standard method performance requirements
[6]   Carbon Paste Electrodes Made from Different Carbonaceous Materials: Application in the Study of Antioxidants [J].
Apetrei, Constantin ;
Mirela Apetrei, Irina ;
Antonio De Saja, Jose ;
Luz Rodriguez-Mendez, Maria .
SENSORS, 2011, 11 (02) :1328-1344
[7]  
ARMSTRONG MD, 1956, J BIOL CHEM, V218, P293
[8]  
Bard A.J., 2001, ELECTROCHEMICAL METH
[9]   Determination of caffeic acid in wine using PEDOT film modified electrode [J].
Bianchini, C. ;
Curulli, A. ;
Pasquali, M. ;
Zane, D. .
FOOD CHEMISTRY, 2014, 156 :81-86
[10]   GAS CHROMATOGRAPHY OF PHENOLIC ACIDS [J].
BLAKLEY, ER .
ANALYTICAL BIOCHEMISTRY, 1966, 15 (02) :350-&