Bubble cloud characteristics and ablation efficiency in dual-frequency intrinsic threshold histotripsy

被引:3
|
作者
Edsall, Connor [1 ]
Huynh, Laura [2 ]
Hall, Timothy L. [3 ]
Vlaisavljevich, Eli [1 ,4 ]
机构
[1] Virginia Polytech Inst & State Univ, Dept Biomed Engn & Mech, 325 Stanger St, Blacksburg, VA 24061 USA
[2] Virginia Polytech Inst & State Univ, Dept Mat Sci & Engn, 445 Old Turner St, Blacksburg, VA 24061 USA
[3] Univ Michigan, Biomed Engn, Carl A Gerstacker Bldg,2200 Bonisteel Blvd, Ann Arbor, MI 48109 USA
[4] Virginia Polytech Inst & State Univ, ICTAS Ctr Engn Hlth, 325 Stanger St, Blacksburg, VA 24061 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2023年 / 68卷 / 22期
关键词
histotripsy; frequency; dual-frequency; bubble cloud dynamics; cavitation; ablation; PULSED CAVITATIONAL ULTRASOUND; SHOCK-WAVE EMISSION; TISSUE STIFFNESS; PROBE;
D O I
10.1088/1361-6560/ad00a5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Histotripsy is a non-thermal focused ultrasound ablation method that destroys tissue through the generation and activity of acoustic cavitation bubble clouds. Intrinsic threshold histotripsy uses single-cycle pulses to generate bubble clouds when the dominant negative pressure phase exceeds an intrinsic threshold of similar to 25-30 MPa. The ablation efficiency is dependent upon the size and density of bubbles within the bubble cloud. This work investigates the effects of dual-frequency pulsing schemes on the bubble cloud behavior and ablation efficiency in intrinsic threshold histotripsy. A modular 500 kHz:3 MHz histotripsy transducer treated agarose phantoms using dual-frequency histotripsy pulses with a 1:1 pressure ratio from 500 kHz and 3 MHz frequency elements and varying arrival times for the 3 MHz pulse relative to the arrival of the 500 kHz pulse (-100 ns, 0 ns, and +100 ns). High-speed optical imaging captured cavitation effects to characterize bubble cloud and individual bubble dynamics. The effects of dual-frequency pulsing on lesion formation and ablation efficiency were also investigated in red blood cell (RBC) phantoms. Results showed that the single bubble and bubble cloud size for dual-frequency cases were intermediate to published results for the component single-frequencies of 500 kHz and 3 MHz. Additionally, bubble cloud size and dynamics were shown to be altered by the arrival time of the 3 MHz pulse with respect to the 500 kHz pulse, with more uniform cloud expansion and collapse observed for early (-100 ns) arrival. Finally, RBC phantom experiments showed that dual-frequency exposures were capable of generating precise lesions with smaller areas and higher ablation efficiencies than previously published results for 500 kHz or 3 MHz. Overall, results demonstrate dual-frequency histotripsy's ability to modulate bubble cloud size and dynamics can be leveraged to produce precise lesions at higher ablation efficiencies than previously observed for single-frequency pulsing.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Dual-beam dual-frequency scanning laser radar for investigation of ablation profiles
    Molebny, VV
    Pallikaris, IG
    Naoumidis, LP
    Kamerman, GW
    Smirnov, EM
    Ilchenko, LM
    Goncharov, VO
    LASER RADAR TECHNOLOGY AND APPLICATIONS, 1996, 2748 : 68 - 75
  • [22] GPU accelerated study of a dual-frequency driven single bubble in a 6-dimensional parameter space: The active cavitation threshold
    Hegedus, Ferenc
    Klapcsik, Kalman
    Lauterborn, Werner
    Parlitz, Ulrich
    Mettin, Robert
    ULTRASONICS SONOCHEMISTRY, 2020, 67
  • [23] High-Intensity Focused Ultrasound Ablation by the Dual-Frequency Excitation
    Law, Siu Kwun Berlinda
    Zhou, Yufeng
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2019, 66 (01) : 18 - 25
  • [24] Effect of different waveforms and harmonic frequency orders on bubble cavitation in dual-frequency ultrasonic intensification
    Seithtanabutara, Varinrumpai
    Jookjantra, Kittichai
    Wongwuttanasatian, Tanakorn
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2020, 157
  • [25] Cloud Assumption of Precipitation Retrieval Algorithms for the Dual-Frequency Precipitation Radar
    Kubota, Takuji
    Seto, Shinta
    Satoh, Masaki
    Nasuno, Tomoe
    Iguchi, Toshio
    Masaki, Takeshi
    Kwiatkowski, John M.
    Oki, Riko
    JOURNAL OF ATMOSPHERIC AND OCEANIC TECHNOLOGY, 2020, 37 (11) : 2015 - 2031
  • [26] Dual-frequency excited combination resonance and global stability of an oscillating cylindrical bubble
    Yu, Jiaxin
    Luo, Jinxin
    Zhang, Xiangqing
    Zhang, Yuning.
    Lu, Zhanhui
    Zhang, Yuning
    PHYSICS OF FLUIDS, 2024, 36 (12)
  • [27] CHARACTERISTICS OF DUAL-FREQUENCY COMBINED VIBRATOR ANTENNA-ARRAYS
    ILYINSKY, AS
    PONOMARYOV, LI
    BEREZHNAYA, IV
    DOLGIJ, AV
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII RADIOELEKTRONIKA, 1984, 27 (02): : 85 - 86
  • [28] Dual-frequency characteristics of Minkowski-square ring antennas
    Vinoy, K. J.
    Pal, A.
    IET MICROWAVES ANTENNAS & PROPAGATION, 2010, 4 (02) : 219 - 224
  • [29] Numerical investigation of the inertial cavitation threshold by dual-frequency excitation in the fluid and tissue
    Wang, Mingjun
    Zhou, Yufeng
    ULTRASONICS SONOCHEMISTRY, 2018, 42 : 327 - 338
  • [30] A Compact Dual-Frequency Square Ring Antenna with Filtering Characteristics
    Schulwitz, Lora
    Harle, Lee
    Killips, Daniel
    2011 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION (APSURSI), 2011, : 149 - 152