Effect of acute CORticosteroids on conduction defects after Transcatheter Aortic Valve Implantation: the CORTAVI study

被引:1
|
作者
Barone, Lucy [1 ,6 ]
Muscoli, Saverio [1 ]
Belli, Martina [2 ,3 ]
Di Luozzo, Marco [1 ]
Sergi, Domenico [1 ]
Marchei, Massimo [1 ]
Prandi, Francesca R. [2 ]
Uccello, Giuseppe [4 ]
Romeo, Francesco [5 ]
Barilla, Francesco [2 ]
机构
[1] Fdn Policlin Tor Vergata, Dept Med Sci, Div Cardiol, Rome, Italy
[2] Univ Roma Tor Vergata, Dept Expt Med, Rome, Italy
[3] Ist Sci San Raffaele, Cardiovasc Imaging Unit, Milan, Italy
[4] IRCCS Osped Galeazzi St Ambrogio, Div Cardiol, Milan, Italy
[5] Univ Hlth & Med Sci, Fac Med, Dept Dept, Unicamillus St Camillus Int, Rome, Italy
[6] Viale Oxford 81, I-00133 Rome, Italy
关键词
bundle branch block and high-grade atrioventricular block; conduction abnormalities; conduction defects; corticosteroids; permanent pacemaker; transcatheter aortic valve implantation; PERMANENT PACEMAKER IMPLANTATION; REPLACEMENT; PREDICTORS; RISK; DEPENDENCY; THERAPY; BLOCK;
D O I
10.2459/JCM.0000000000001516
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
AimsConduction abnormalities, requiring a permanent pacemaker (PPM), are the most common electrical complications after transcatheter aortic valve implantation (TAVI). The exact mechanism for conduction system defects is not yet clear. The local inflammatory process and edema are thought to play a role in the development of electrical disorders. Corticosteroids are effective anti-inflammatory and antiedematous agents. We aim to investigate the potential protective effect of corticosteroids on conduction defects after TAVI.MethodsThis is a retrospective study of a single center. We analyzed 96 patients treated with TAVI. Thirty-two patients received oral prednisone 50 mg for 5 days after the procedure. This population was compared with the control group. All patients were followed up after 2 years.ResultsOf the 96 patients included, 32 (34%) were exposed to glucocorticoids after TAVI. No differences in age, preexisting right bundle branch block or left bundle branch block, or valve type were seen among patients exposed to glucocorticoids versus those who were unexposed. We observed no significant differences between the two groups in the overall frequency of new PPM implantations during hospitalization (12% vs. 17%, P = 0.76). The incidence of atrioventricular block (AVB) (STx 9% vs. non-STx 9%, P = 0.89), right bundle branch block (STx 6% vs. non-STx 11%, P = 0.71), and left bundle branch block (STx 34% vs. non-STx 31%, P = 0.9) was not significantly different between the STx and non-STx groups. At 2 years after TAVI, none of the patients had implanted PPM or had severe arrhythmias documented by 24-h Holter ECG or cardiac examination.ConclusionOral prednisone treatment does not appear to significantly reduce the incidence of AVB requiring acute PPM implantation after TAVI.
引用
收藏
页码:676 / 679
页数:4
相关论文
共 50 条
  • [31] Conduction dynamics after transcatheter aortic valve implantation and implications for permanent pacemaker implantation and early discharge: the CONDUCT-study
    van Gils, Lennart
    Baart, Sara
    Kroon, Herbert
    Rahhab, Zouhair
    El Faquir, Nahid
    Olivares, Ramon Rodriguez
    Aga, Yaar
    Maugenest, Anne-Marie
    Theuns, Dominic A.
    Boersma, Eric
    Torok, Tamas Szili
    De Jaegere, Peter P.
    Van Mieghem, Nicolas M.
    EUROPACE, 2018, 20 (12): : 1981 - 1988
  • [32] Conduction Disturbance, Pacemaker Rates, and Hospital Length of Stay Following Transcatheter Aortic Valve Implantation with the Sapien 3 Valve
    Isogai, Toshiaki
    Shekhar, Shashank
    Saad, Anas M.
    Abdelfattah, Omar M.
    Tarakji, Khaldoun G.
    Wazni, Oussama M.
    Kalra, Ankur
    Yun, James J.
    Krishnaswamy, Amar
    Reed, Grant W.
    Kapadia, Samir R.
    Puri, Rishi
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2022, 6 (03):
  • [33] Effect of a restrictive pacemaker implantation strategy on mortality after transcatheter aortic valve implantation
    Schoechlin, Simon
    Minners, Jan
    Jadidi, Amir
    Abduljalil, Fares
    Ruile, Philip
    Neumann, Franz-Josef
    Arentz, Thomas
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2021, 44 (02): : 240 - 246
  • [34] Reevaluation of the Indications for Permanent Pacemaker Implantation After Transcatheter Aortic Valve Implantation
    Thygesen, Julie Bjerre
    Poay Huan Loh
    Cholteesupachai, Jiranut
    Franzen, Olaf
    Sondergaard, Lars
    JOURNAL OF INVASIVE CARDIOLOGY, 2014, 26 (02) : 94 - 99
  • [35] Conduction Disturbance After Transcatheter Aortic Valve Implantation With Self- or Balloon-Expandable Valve According to the Implantation Depth
    Miyashita, Hirokazu
    Moriyama, Noriaki
    Sugiyama, Yoichi
    Jalanko, Mikko
    Dahlbacka, Sebastian
    Vahasilta, Tommi
    Vainikka, Tiina
    Viikila, Juho
    Laine, Mika
    AMERICAN JOURNAL OF CARDIOLOGY, 2023, 203 : 17 - 22
  • [36] Infective endocarditis after transcatheter aortic valve implantation: a nationwide study
    Bjursten, Henrik
    Rasmussen, Magnus
    Nozohoor, Shahab
    Gotberg, Mattias
    Olaison, Lars
    Ruck, Andreas
    Ragnarsson, Sigurdur
    EUROPEAN HEART JOURNAL, 2019, 40 (39) : 3263 - +
  • [37] Intraoperative Corticosteroids and Pacemaker Implantation After Transcatheter Aortic Valve Replacement
    Tiago, Catarina
    Vaz, Marta Dias
    Marques, Ana
    Barata, Melanie
    Braga, Jose Pedro
    Boa, Ana
    Carvalho, Ana Filipa
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (03)
  • [38] Timing of Onset and Outcome of New Conduction Abnormalities Following Transcatheter Aortic Valve Implantation: Role of Balloon Aortic Valvuloplasty
    Campelo-Parada, Francisco
    Nombela-Franco, Luis
    Urena, Marina
    Regueiro, Ander
    Jimenez-Quevedo, Pilar
    Del Trigo, Maria
    Chamandi, Chekrallah
    Rodriguez-Gabella, Tania
    Auffret, Vincent
    Altisent, Omar Abdul-Jawad
    DeLarochelliere, Robert
    Paradis, Jean-Michel
    Dumont, Eric
    Philippon, Francois
    Perez-Castellano, Nicasio
    Puri, Rishi
    Macaya, Carlos
    Rodes-Cabau, Josep
    REVISTA ESPANOLA DE CARDIOLOGIA, 2018, 71 (03): : 162 - 169
  • [39] Structural Changes of the Right Fibrous Trigone as a Risk Factor for Conduction Disturbance After Transcatheter Aortic Valve Implantation
    Aslan, Serkan
    Turkvatan, Aysel
    Topel, Cagdas
    Guner, Ahmet
    Demir, Ali Riza
    Kahraman, Serkan
    Celik, Omer
    Erturk, Mehmet
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2022, 26 (07) : 532 - 542
  • [40] Left Bundle Branch Block after Transcatheter Aortic Valve Implantation with Edwards Sapien 3 Valve: Influence of the Valve Depth Implantation
    Unzue, Leire
    Garcia, Eulogio
    Diaz-Anton, Belen
    Jose Rodriguez-Rodrigo, Francisco
    Rodriguez del Rio, Miguel
    Teijeiro, Rodrigo
    Medina, Juan
    Javier Parra, Francisco
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2019, 20 (11) : 949 - 955