Advancement of a high-dose infant air-jet dry powder inhaler (DPI) with passive cyclic loading: Performance tuning for different formulations

被引:5
作者
Howe, Connor [1 ]
Momin, Mohammad A. M. [2 ]
Aladwani, Ghali [1 ]
Strickler, Sarah [1 ]
Hindle, Michael [2 ]
Longest, Worth [1 ,2 ,3 ]
机构
[1] Virginia Commonwealth Univ, Dept Mech & Nucl Engn, 401 W Main St, POB 843015, Richmond, VA 23284 USA
[2] Virginia Commonwealth Univ, Dept Pharmaceut, 410 N 12th St, POB 980533, Richmond, VA 23284 USA
[3] Virginia Commonwealth Univ, 401 West Main St,POB 843015, Richmond, VA 23284 USA
基金
美国国家卫生研究院;
关键词
Trans-nasal aerosol delivery; Nose-to-lung aerosol delivery; Infant DPI; Inline DPI; Powder insufflation; AEROSOL DEPOSITION; IN-VITRO; DELIVERY; CHILDREN; NEBULIZER; DRUGS;
D O I
10.1016/j.ijpharm.2023.123199
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
There is a current medical need for a dry powder aerosol delivery device that can be used to efficiently and consistently administer high dose therapeutics, such as inhaled antibiotics, surfactants and antivirals, to the lungs of infants. This study considered an infant air-jet dry powder inhaler (DPI) that could be actuated multiple times with minimal user interaction (i.e., a passive cyclic loading strategy) and focused on the development of a metering system that could be tuned for individual powder formulations to maintain high efficiency lung delivery. The metering system consisted of a powder delivery tube (PDT) connecting a powder reservoir with an aerosolization chamber and a powder supporting shelf that held a defined formulation volume. Results indicated that the metering system could administer a consistent dose per actuation after reaching a steady state condition. Modifications of the PDT diameter and shelf volume provided a controllable approach that could be tuned to maximize lung delivery efficiency for three different formulations. Using optimized metering system conditions for each formulation, the infant air-jet DPI was found to provide efficient and consistent lung delivery of aerosols (similar to 45% of loaded dose) based on in vitro testing with a preterm nose-throat model and limited dose/actuation to <5 mg.
引用
收藏
页数:11
相关论文
共 36 条
  • [11] Efficient Nose-to-Lung Aerosol Delivery with an Inline DPI Requiring Low Actuation Air Volume
    Farkas, Dale
    Hindle, Michael
    Longest, P. Worth
    [J]. PHARMACEUTICAL RESEARCH, 2018, 35 (10)
  • [12] Fink James B, 2004, Respir Care, V49, P653
  • [13] Delivery of Inhaled Drugs for Infants and Small Children: A Commentary on Present and Future Needs
    Fink, James B.
    [J]. CLINICAL THERAPEUTICS, 2012, 34 (11) : S36 - S45
  • [14] Fok TF, 1996, PEDIATR PULM, V21, P301, DOI 10.1002/(SICI)1099-0496(199605)21:5<301::AID-PPUL5>3.0.CO
  • [15] 2-P
  • [16] Pulmonary deposition of salbutamol aerosol delivered by metered dose inhaler, jet nebulizer, and ultrasonic nebulizer in mechanically ventilated rabbits
    Fok, TF
    AlEssa, M
    Monkman, S
    Dolovich, M
    Girard, L
    Coates, G
    Kirpalani, H
    [J]. PEDIATRIC RESEARCH, 1997, 42 (05) : 721 - 727
  • [17] Development of a High-Dose Infant Air-Jet Dry Powder Inhaler (DPI) with Passive Cyclic Loading of the Formulation
    Howe, Connor
    Momin, Mohammad A. M.
    Aladwani, Ghali
    Hindle, Michael
    Longest, P. Worth
    [J]. PHARMACEUTICAL RESEARCH, 2022, 39 (12) : 3317 - 3330
  • [18] In Vitro Analysis of Nasal Interface Options for High-Efficiency Aerosol Administration to Preterm Infants
    Howe, Connor
    Momin, Mohammad A. M.
    Bass, Karl
    Aladwani, Ghali
    Bonasera, Serena
    Hindle, Michael
    Longest, Philip Worth
    [J]. JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2022, 35 (04) : 196 - 211
  • [19] Advancement of the Infant Air-Jet Dry Powder Inhaler (DPI): Evaluation of Different Positive-Pressure Air Sources and Flow Rates
    Howe, Connor
    Momin, Mohammad A. M.
    Farkas, Dale R.
    Bonasera, Serena
    Hindle, Michael
    Longest, P. Worth
    [J]. PHARMACEUTICAL RESEARCH, 2021, 38 (09) : 1615 - 1632
  • [20] Initial Development of an Air-Jet Dry Powder Inhaler for Rapid Delivery of Pharmaceutical Aerosols to Infants
    Howe, Connor
    Hindle, Michael
    Bonasera, Serena
    Rani, Vijaya
    Longest, P. Worth
    [J]. JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2021, 34 (01) : 57 - 70