Implantable cardioverter defibrillator lead performance: A systematic review and individual patient data Meta-analysis

被引:3
作者
Giacopelli, Daniele [1 ,2 ,8 ]
Azzolina, Danila [3 ]
Comoretto, Rosanna Irene [4 ]
Quartieri, Fabio [5 ]
Rovaris, Giovanni [6 ]
Schillaci, Vincenzo [7 ]
Gargaro, Alessio [2 ]
Gregori, Dario [1 ]
机构
[1] Univ Padua, Dept Cardiac Thorac Vasc Sci & Publ Hlth, Padua, Italy
[2] Biotronik Italia, Clin Unit, Milan, Italy
[3] Univ Ferrara, Dept Environm & Prevent Sci, Ferrara, Italy
[4] Univ Torino, Dept Publ Hlth & Pediat, Turin, Italy
[5] Arcispedale Santa Maria Nuova, Dept Cardiol, Reggio Emilia, Italy
[6] Osped San Gerardo, Dept Cardiol, Monza, Italy
[7] Clin Montevergine, Electrophysiol Unit, Mercogliano, Italy
[8] Univ Padua, Dept Cardiac Thorac Vasc Sci & Publ Hlth, Via Giustiniani 2, I-35128 Padua, Italy
关键词
Implantable cardioverter-defibrillator; Post market surveillance; ICD leads; Failure; meta; -analysis; LONG-TERM PERFORMANCE; SPRINT FIDELIS; FAILURE RATES; BIOTRONIK LINOX; RIATA; RISK; SURVIVAL; SURVEILLANCE; MULTICENTER; DYSFUNCTION;
D O I
10.1016/j.ijcard.2022.11.048
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Reliable post-approval surveillance of implantable cardioverter-defibrillator (ICD) lead performance remains a challenge. In the past, two ICD leads were recalled due to a high frequency of failures. In this meta -analysis, we sought to provide a combined estimate of failure-free rate for ICD leads by reconstructing individual patient data from published Kaplan-Meier (KM) curves and to investigate whether estimates could be influenced by the characteristics of the study.Methods: Observational studies assessing failure-free estimates of transvenous ICD leads with KM method, were identified through a systematic search up to November 2021.Results: Forty-four studies were eligible that included 41,870 (63.1%) non-recalled leads and 24,493 (36.9%) recalled leads. The 8-year cumulative failure-free rate was 94.1% (CI, 93.6% -94.6%) for contemporary non-recalled leads and 81.2% (80.3% -82.0%) for recalled leads (hazard ratio [HR], 3.15 [2.85-3.47], p < 0.001). Failure-free rate was lower in single-center studies in both the non-recalled (HR, 0.28 [0.15-0.51], p < 0.001) and recalled (HR, 0.54 [0.33-0.88], p = 0.014) group compared with multicenter studies. Similarly, estimates were significantly lower in small (i.e. extracted KM curve with <312 leads) versus large studies (HR non-recalled group, 0.54 [CI, 0.33-0.89], p = 0.015; HR recalled group, 0.62 [CI, 0.43-0.89], p = 0.009). Conclusions: In this meta-analysis including >66,000 leads, we provide pooled survival curves that may play a role in generating evidence-based standards for assessing clinically acceptable failure rates for ICD leads. Lead performance was underestimated with single-center and small-sized studies; multicenter studies remain the main tool to reliably conduct post-market surveillance of ICD leads.
引用
收藏
页码:57 / 63
页数:7
相关论文
共 50 条
[41]   Implantable cardioverter defibrillators in left ventricular assist device patients: A systematic review and meta-analysis [J].
Rorris, Filippos-Paschalis ;
Antonopoulos, Constantine N. ;
Kyriakopoulos, Christos P. ;
Drakos, Stavros G. ;
Charitos, Christos .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2021, 40 (10) :1098-1106
[42]   Outcomes following implantable cardioverter-defibrillator generator replacement in adults: A systematic review [J].
McCarthy, Killian J. ;
Locke, Andrew H. ;
Coletti, Margo ;
Young, Diane ;
Merchant, Faisal M. ;
Kramer, Daniel B. .
HEART RHYTHM, 2020, 17 (06) :1036-1042
[43]   The experience of patients with an implantable cardioverter-defibrillator: a systematic review and meta-synthesis of qualitative studies [J].
Barisone, Michela ;
Hayter, Mark ;
Ghirotto, Luca ;
Catania, Gianluca ;
Zanini, Milko ;
Dal Molin, Alberto ;
Sasso, Loredana ;
Bagnasco, Annamaria .
EUROPEAN JOURNAL OF CARDIOVASCULAR NURSING, 2022, 21 (07) :677-686
[44]   All cause mortality of cardiac resynchronization therapy with implantable cardioverter defibrillator: A meta-analysis of randomized controlled trials [J].
Huang, Yanlan ;
Wu, Weifeng ;
Cao, Yunfei ;
Qu, Nan .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 145 (03) :413-417
[45]   Performance of the Durata implantable cardioverter defibrillator lead: results of an independent multicenter study [J].
Rordorf, Roberto ;
Taravelli, Erika ;
Forleo, Giovanni B. ;
Giannola, Gabriele ;
Calzolari, Vittorio ;
Tadeo, Giorgio ;
Rossi, Stefano ;
Vicentini, Alfredo ;
Curnis, Antonio ;
Serra, Paolo ;
Santamaria, Matteo ;
Calo, Leonardo .
JOURNAL OF CARDIOVASCULAR MEDICINE, 2019, 20 (10) :676-681
[46]   Impact of prolonged implantable cardioverter-defibrillator arrhythmia detection times on outcomes: A meta-analysis [J].
Scott, Paul A. ;
Silberbauer, John ;
McDonagh, Theresa A. ;
Murgatroyd, Francis D. .
HEART RHYTHM, 2014, 11 (05) :828-835
[47]   Amiodarone for arrhythmia in patients with Chagas disease: A systematic review and individual patient data meta-analysis [J].
Stein, Cinara ;
Migliavaca, Celina Borges ;
Colpani, Veronica ;
da Rosa, Priscila Raupp ;
Sganzerla, Daniel ;
Giordani, Natalia Elis ;
Pinto de Sousa Miguel, Sandro Rene ;
Cruz, Luciane Nascimento ;
Polanczyk, Carisi Anne ;
Ribeiro, Antonio Luiz P. ;
Falavigna, Maicon .
PLOS NEGLECTED TROPICAL DISEASES, 2018, 12 (08)
[48]   Implantable cardioverter-defibrillator use in elderly patients receiving cardiac resynchronization: A meta-analysis [J].
AlTurki, Ahmed ;
Proietti, Riccardo ;
Alturki, Hasan ;
Essebag, Vidal ;
Thao Huynh .
HELLENIC JOURNAL OF CARDIOLOGY, 2019, 60 (05) :276-281
[49]   Two-incision versus three-incision implantation technique of subcutaneous implantable cardioverter defibrillator: Systematic review and meta-analysis of 2076 patients [J].
Elkasaby, Mohamed Hamouda ;
Khalefa, Basma Badrawy ;
Yassin, Mazen Negmeldin Aly ;
El-Hameed, Malak Mohamed Abd ;
Elkoumi, Omar ;
Al Hennawi, Hussam .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2024, 47 (02) :281-291
[50]   Implantable Cardioverter-Defibrillators in Trials of Drug Therapy for Heart Failure: A Systematic Review and Meta-Analysis [J].
Gama, Francisco ;
Ferreira, Jorge ;
Carmo, Joao ;
Costa, Francisco Moscoso ;
Carvalho, Salome ;
Carmo, Pedro ;
Cavaco, Diogo ;
Morgado, Francisco Belo ;
Adragao, Pedro ;
Mendes, Miguel .
JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2020, 9 (08)