Implantable cardioverter defibrillator lead performance: A systematic review and individual patient data Meta-analysis

被引:3
作者
Giacopelli, Daniele [1 ,2 ,8 ]
Azzolina, Danila [3 ]
Comoretto, Rosanna Irene [4 ]
Quartieri, Fabio [5 ]
Rovaris, Giovanni [6 ]
Schillaci, Vincenzo [7 ]
Gargaro, Alessio [2 ]
Gregori, Dario [1 ]
机构
[1] Univ Padua, Dept Cardiac Thorac Vasc Sci & Publ Hlth, Padua, Italy
[2] Biotronik Italia, Clin Unit, Milan, Italy
[3] Univ Ferrara, Dept Environm & Prevent Sci, Ferrara, Italy
[4] Univ Torino, Dept Publ Hlth & Pediat, Turin, Italy
[5] Arcispedale Santa Maria Nuova, Dept Cardiol, Reggio Emilia, Italy
[6] Osped San Gerardo, Dept Cardiol, Monza, Italy
[7] Clin Montevergine, Electrophysiol Unit, Mercogliano, Italy
[8] Univ Padua, Dept Cardiac Thorac Vasc Sci & Publ Hlth, Via Giustiniani 2, I-35128 Padua, Italy
关键词
Implantable cardioverter-defibrillator; Post market surveillance; ICD leads; Failure; meta; -analysis; LONG-TERM PERFORMANCE; SPRINT FIDELIS; FAILURE RATES; BIOTRONIK LINOX; RIATA; RISK; SURVIVAL; SURVEILLANCE; MULTICENTER; DYSFUNCTION;
D O I
10.1016/j.ijcard.2022.11.048
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Reliable post-approval surveillance of implantable cardioverter-defibrillator (ICD) lead performance remains a challenge. In the past, two ICD leads were recalled due to a high frequency of failures. In this meta -analysis, we sought to provide a combined estimate of failure-free rate for ICD leads by reconstructing individual patient data from published Kaplan-Meier (KM) curves and to investigate whether estimates could be influenced by the characteristics of the study.Methods: Observational studies assessing failure-free estimates of transvenous ICD leads with KM method, were identified through a systematic search up to November 2021.Results: Forty-four studies were eligible that included 41,870 (63.1%) non-recalled leads and 24,493 (36.9%) recalled leads. The 8-year cumulative failure-free rate was 94.1% (CI, 93.6% -94.6%) for contemporary non-recalled leads and 81.2% (80.3% -82.0%) for recalled leads (hazard ratio [HR], 3.15 [2.85-3.47], p < 0.001). Failure-free rate was lower in single-center studies in both the non-recalled (HR, 0.28 [0.15-0.51], p < 0.001) and recalled (HR, 0.54 [0.33-0.88], p = 0.014) group compared with multicenter studies. Similarly, estimates were significantly lower in small (i.e. extracted KM curve with <312 leads) versus large studies (HR non-recalled group, 0.54 [CI, 0.33-0.89], p = 0.015; HR recalled group, 0.62 [CI, 0.43-0.89], p = 0.009). Conclusions: In this meta-analysis including >66,000 leads, we provide pooled survival curves that may play a role in generating evidence-based standards for assessing clinically acceptable failure rates for ICD leads. Lead performance was underestimated with single-center and small-sized studies; multicenter studies remain the main tool to reliably conduct post-market surveillance of ICD leads.
引用
收藏
页码:57 / 63
页数:7
相关论文
共 50 条
[31]   Systematic Review and Meta-Analysis of Clinical Outcome After Implantable Cardioverter-Defibrillator Therapy in Patients With Chagas Heart Disease [J].
Rassi, Fabio Mahamed ;
Minohara, Lucas ;
Rassi Jr, Anis ;
Lemos Correia, Luis Claudio ;
Marin-Neto, Jose Antonio ;
Rassi, Anis ;
Menezes Jr, Antonio da Silva .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2019, 5 (10) :1213-1223
[32]   ECMO for severe ARDS: systematic review and individual patient data meta-analysis [J].
Combes, Alain ;
Peek, Giles J. ;
Hajage, David ;
Hardy, Pollyanna ;
Abrams, Darryl ;
Schmidt, Matthieu ;
Dechartres, Agnes ;
Elbourne, Diana .
INTENSIVE CARE MEDICINE, 2020, 46 (11) :2048-2057
[33]   Efficacy and safety of the subcutaneous implantable cardioverter-defibrillator in patients with and without obesity: A meta-analysis [J].
Vamos, Mate ;
Zsigmond, Elod-Janos ;
Biffi, Mauro ;
Gausz, Flora Diana ;
Keller, Nora ;
Kupo, Peter ;
Szili-Torok, Tamas ;
Ziacchi, Matteo ;
Benz, Alexander P. ;
Spittler, Raphael ;
Vagvolgyi, Anna .
HEART RHYTHM, 2025, 22 (02) :375-387
[34]   Implantable cardioverter-defibrillator harm in young patients with inherited arrhythmia syndromes: A systematic review and meta-analysis of inappropriate shocks and complications [J].
Nordkamp, Louise R. A. Olde ;
Postema, Pieter G. ;
Knops, Reinoud E. ;
van Dijk, Nynke ;
Limpens, Jacqueline ;
Wilde, Arthur A. M. ;
de Groot, Joris R. .
HEART RHYTHM, 2016, 13 (02) :443-454
[35]   Implantable cardioverter-defibrillator in patients with inherited arrhythmia syndromes: A systematic review [J].
Medeiros, Paulo ;
Santos, Maria ;
Arantes, Carina ;
Pereira, Vitor Hugo ;
Rocha, Sergia .
HEART & LUNG, 2023, 60 :1-7
[36]   Estimating the Risks and Benefits of Implantable Cardioverter Defibrillator Generator Replacement: A Systematic Review [J].
Lewis, Krystina B. ;
Stacey, Dawn ;
Carroll, Sandra L. ;
Boland, Laura ;
Sikora, Lindsey ;
Birnie, David .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2016, 39 (07) :709-722
[37]   Long-Term Performance of the Riata/ST Implantable Cardioverter-Defibrillator Lead [J].
Stroeker, Erwin ;
de Asmundis, Carlo ;
Vanduynhoven, Philippe ;
De Vadder, Katrien ;
De Vusser, Philip ;
Mullens, Wilfried ;
Chierchia, Gian-Battista ;
Brugada, Pedro ;
Czapla, Jens ;
La Meir, Mark ;
Wellens, Francis ;
Van Herendael, Hugo ;
Rivero-Ayerza, Maximo .
AMERICAN JOURNAL OF CARDIOLOGY, 2016, 117 (05) :807-812
[38]   Multiple brain arteriovenous malformations: systematic review and individual patient data meta-analysis [J].
Basilio-Flores, Juan E. ;
Aguilar-Melgar, Joel A. ;
Zevallos, Cynthia B. ;
Aguirre-Carbajo, Remy ;
Ortega-Gutierrez, Santiago ;
Baca, Henry Pacheco-Fernandez .
NEUROSURGICAL REVIEW, 2023, 46 (01)
[39]   Impact of early ventricular tachycardia ablation in patients with an implantable cardioverter-defibrillator: An updated systematic review and meta-analysis of randomized controlled trials [J].
Prasitlumkum, Narut ;
Navaravong, Leenhapong ;
Desai, Aditya ;
Desai, Darshi ;
Cheungpasitporn, Wisit ;
Rattanawong, Pattara ;
Bunch, T. Jared ;
Jongnarangsin, Krit ;
Chokesuwattanaskul, Ronpichai .
HEART RHYTHM, 2022, 19 (12) :2054-2061
[40]   Device infections in implantable cardioverter defibrillators versus permanent pacemakers: A systematic review and meta-analysis [J].
Rattanawong, Pattara ;
Kewcharoen, Jakrin ;
Mekraksakit, Poemlarp ;
Mekritthikrai, Raktham ;
Prasitlumkum, Narut ;
Vutthikraivit, Wasawat ;
Putthapiban, Prapaipan ;
Dworkin, Jonathan .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (07) :1053-1065