Implantable cardioverter defibrillator lead performance: A systematic review and individual patient data Meta-analysis

被引:3
作者
Giacopelli, Daniele [1 ,2 ,8 ]
Azzolina, Danila [3 ]
Comoretto, Rosanna Irene [4 ]
Quartieri, Fabio [5 ]
Rovaris, Giovanni [6 ]
Schillaci, Vincenzo [7 ]
Gargaro, Alessio [2 ]
Gregori, Dario [1 ]
机构
[1] Univ Padua, Dept Cardiac Thorac Vasc Sci & Publ Hlth, Padua, Italy
[2] Biotronik Italia, Clin Unit, Milan, Italy
[3] Univ Ferrara, Dept Environm & Prevent Sci, Ferrara, Italy
[4] Univ Torino, Dept Publ Hlth & Pediat, Turin, Italy
[5] Arcispedale Santa Maria Nuova, Dept Cardiol, Reggio Emilia, Italy
[6] Osped San Gerardo, Dept Cardiol, Monza, Italy
[7] Clin Montevergine, Electrophysiol Unit, Mercogliano, Italy
[8] Univ Padua, Dept Cardiac Thorac Vasc Sci & Publ Hlth, Via Giustiniani 2, I-35128 Padua, Italy
关键词
Implantable cardioverter-defibrillator; Post market surveillance; ICD leads; Failure; meta; -analysis; LONG-TERM PERFORMANCE; SPRINT FIDELIS; FAILURE RATES; BIOTRONIK LINOX; RIATA; RISK; SURVIVAL; SURVEILLANCE; MULTICENTER; DYSFUNCTION;
D O I
10.1016/j.ijcard.2022.11.048
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Reliable post-approval surveillance of implantable cardioverter-defibrillator (ICD) lead performance remains a challenge. In the past, two ICD leads were recalled due to a high frequency of failures. In this meta -analysis, we sought to provide a combined estimate of failure-free rate for ICD leads by reconstructing individual patient data from published Kaplan-Meier (KM) curves and to investigate whether estimates could be influenced by the characteristics of the study.Methods: Observational studies assessing failure-free estimates of transvenous ICD leads with KM method, were identified through a systematic search up to November 2021.Results: Forty-four studies were eligible that included 41,870 (63.1%) non-recalled leads and 24,493 (36.9%) recalled leads. The 8-year cumulative failure-free rate was 94.1% (CI, 93.6% -94.6%) for contemporary non-recalled leads and 81.2% (80.3% -82.0%) for recalled leads (hazard ratio [HR], 3.15 [2.85-3.47], p < 0.001). Failure-free rate was lower in single-center studies in both the non-recalled (HR, 0.28 [0.15-0.51], p < 0.001) and recalled (HR, 0.54 [0.33-0.88], p = 0.014) group compared with multicenter studies. Similarly, estimates were significantly lower in small (i.e. extracted KM curve with <312 leads) versus large studies (HR non-recalled group, 0.54 [CI, 0.33-0.89], p = 0.015; HR recalled group, 0.62 [CI, 0.43-0.89], p = 0.009). Conclusions: In this meta-analysis including >66,000 leads, we provide pooled survival curves that may play a role in generating evidence-based standards for assessing clinically acceptable failure rates for ICD leads. Lead performance was underestimated with single-center and small-sized studies; multicenter studies remain the main tool to reliably conduct post-market surveillance of ICD leads.
引用
收藏
页码:57 / 63
页数:7
相关论文
共 50 条
  • [21] Performance of Lead Integrity Alert to Assist in the Clinical Diagnosis of Implantable Cardioverter Defibrillator Lead Failures Analysis of Different Implantable Cardioverter Defibrillator Leads
    Ellenbogen, Kenneth A.
    Gunderson, Bruce D.
    Stromberg, Kurt D.
    Swerdlow, Charles D.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (06) : 1169 - 1177
  • [22] Association between fine particulate matter and atrial fibrillation in implantable cardioverter defibrillator patients: a systematic review and meta-analysis
    Yue, Chao
    Yang, Fan
    Wang, Luyi
    Li, Fengwei
    Chen, Yingtai
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2020, 59 (03) : 595 - 601
  • [23] Atrial Fibrillation Is Associated With Higher Overall Mortality in Patients With Implantable Cardioverter-Defibrillator: A Systematic Review and Meta-Analysis
    Mustafa, Usman
    Dherange, Parinita
    Reddy, Rohit
    DeVillier, Joseph
    Chong, Jessica
    Ihsan, Alarozia
    Jones, Ryan
    Duddyala, Narendra
    Reddy, Pratap
    Dominic, Paari
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2018, 7 (22):
  • [24] Association between fine particulate matter and atrial fibrillation in implantable cardioverter defibrillator patients: a systematic review and meta-analysis
    Chao Yue
    Fan Yang
    Luyi Wang
    Fengwei Li
    Yingtai Chen
    Journal of Interventional Cardiac Electrophysiology, 2020, 59 : 595 - 601
  • [25] Implantable cardioverter defibrillator therapy in chronic kidney disease: a meta-analysis
    Korantzopoulos, Panagiotis
    Liu, Tong
    Li, Lijian
    Goudevenos, John A.
    Li, Guangping
    EUROPACE, 2009, 11 (11): : 1469 - 1475
  • [26] The subcutaneous implantable cardioverter defibrillator-review of the recent data
    Westerman, Stacy B.
    El-Chami, Mikhael
    JOURNAL OF GERIATRIC CARDIOLOGY, 2018, 15 (03) : 222 - 228
  • [27] Predictors of Mortality in Patients With an Implantable Cardiac Defibrillator: A Systematic Review and Meta-analysis
    Alba, Ana C.
    Braga, Juarez
    Gewarges, Mena
    Walter, Stephen D.
    Guyatt, Gordon H.
    Ross, Heather J.
    CANADIAN JOURNAL OF CARDIOLOGY, 2013, 29 (12) : 1729 - 1740
  • [28] Implantable cardioverter-defibrillators in adults with congenital heart disease: a systematic review and meta-analysis
    Vehmeijer, Jim T.
    Brouwer, Tom F.
    Limpens, Jacqueline
    Knops, Reinoud E.
    Bouma, Berto J.
    Mulder, Barbara J. M.
    de Groot, Joris R.
    EUROPEAN HEART JOURNAL, 2016, 37 (18) : 1439 - 1448
  • [29] Importance of Implantable Cardioverter-Defibrillator Back-Up in Cardiac Resynchronization Therapy Recipients: A Systematic Review and Meta-Analysis
    Barra, Sergio
    Providencia, Rui
    Tang, Anthony
    Heck, Patrick
    Virdee, Munmohan
    Agarwal, Sharad
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2015, 4 (11):
  • [30] Systematic Review and Meta-Analysis of Clinical Outcome After Implantable Cardioverter-Defibrillator Therapy in Patients With Chagas Heart Disease
    Rassi, Fabio Mahamed
    Minohara, Lucas
    Rassi Jr, Anis
    Lemos Correia, Luis Claudio
    Marin-Neto, Jose Antonio
    Rassi, Anis
    Menezes Jr, Antonio da Silva
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2019, 5 (10) : 1213 - 1223