Development of Electrically Conductive Cold Weather Cement Concrete

被引:6
作者
Abubakri, Shahriar [1 ]
Lomboy, Gilson R. R. [1 ]
Kennedy, Danielle [2 ]
Watts, Benjamin [2 ]
机构
[1] Rowan Univ, Ctr Res Educ Adv Transportat Engn Syst, Dept Civil & Environm Engn, 201 Mull Hill Rd, Glassboro, NJ 08028 USA
[2] US Army Corps Engineers, Cold Reg Res & Engn Lab, Engineer Res & Dev Ctr, 72 Lyme Rd, Hannover, Germany
关键词
Cold weather; Conductive concrete; Additive-based freeze protection; Heating; FRESH CONCRETE; RESISTIVITY; PARAMETERS; PAVEMENT;
D O I
10.1061/JCRGEI.CRENG-674
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Placing fresh cement concrete is not permitted during cold weather under normal conditions due to the risk of frost damage. On the other hand, electrically conductive concrete can be used for deicing/snow-melting applications. This paper presents laboratory investigations to develop electrically conductive cold weather concrete (ECCWC) that can be cast and cured below freezing temperatures and has sufficient electrical conductivity for Joule heating. The concrete has additive-based freeze protection (ABFP) systems that consist of optimized amounts of accelerators and corrosion-inhibiting admixtures. Several mixture proportions were made with 0.5%, 0.75%, and 1.0% carbon fibers by volume of concrete to increase the concrete's conductivity. ECCWC specimens were mixed, cast, and cured at -5 degrees C. The measured freezing points of fresh concrete mixtures were below -5 degrees C. The compressive strength development of ECCWC cured at -5 degrees C was slow compared with the strength development of conductive concrete cured at 20 degrees C. However, ECCWC could reach 55 MPa at 28 days of age. The temperature of hardened ECCWC increased by 18.5 degrees C within 20 min when subjected to a potential difference of 30 V (alternating current). ABFP implemented in the ECCWC mixtures reduces the risk of frost damage and provides the opportunity to place fresh conductive cold weather concrete at ambient temperatures of -5 degrees C without the need for taking curing precautions. The developed ECCWC introduces a new method for constructing multifunctional concrete structures to be placed and cured in cold regions.
引用
收藏
页数:9
相关论文
共 39 条
[1]   Electric curing parameters of mortar and its mechanical properties in cold weather [J].
Abubakri, Shahriar ;
Mangat, P. S. ;
Starinieri, Vincenzo ;
Lomboy, Gilson R. .
CONSTRUCTION AND BUILDING MATERIALS, 2022, 314
[2]  
ACI (American Concrete Institute), 2016, 306R ACI
[3]  
[Anonymous], 2020, Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
[4]  
[Anonymous], 2015, C143C143M15A ASTM, DOI DOI 10.1520/C0143_C0143M-20
[5]  
[Anonymous], 2017, STANDARD TEST METHOD
[6]  
[Anonymous], 2012, Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement, DOI [10.1520/C0618, DOI 10.1520/C0618-19, 10.1520/C0618-19]
[7]  
[Anonymous], 2012, ASTM C 1760 (Standard Test Method for Bulk Electrical Conductivity of Hardened Concrete)
[8]  
Barna L.A., 2014, Extending the season for concrete construction and repair, phase IIIGuidance for optimizing admixture dosage rates
[9]   A feasibility study of self-heating concrete utilizing carbon nanofiber heating elements [J].
Chang, Christiana ;
Ho, Michelle ;
Song, Gangbing ;
Mo, Yi-Lung ;
Li, Hui .
SMART MATERIALS AND STRUCTURES, 2009, 18 (12)
[10]   Effect of fibers on expansion of concrete with a large amount of high f-CaO fly ash [J].
Chen, B ;
Liu, JY .
CEMENT AND CONCRETE RESEARCH, 2003, 33 (10) :1549-1552