Optomechanical assessment of photorefractive corneal cross-linking via optical coherence elastography

被引:2
作者
Frigelli, Matteo [1 ]
Buchler, Philippe [1 ]
Kling, Sabine [1 ,2 ]
机构
[1] Univ Bern, ARTORG Ctr Biomed Engn Res, Computat Bioengn Grp, Bern, Switzerland
[2] Swiss Fed Inst Technol, Inst Biomed Engn, ITET Dept, Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
optical coherence elastography; corneal cross-linking; optomechanical changes; accelerated CXL; ambient pressure modulation; corneal biomechanics. (Min.5-Max. 8; BRILLOUIN MICROSCOPY; DEFORMATION; BIOMECHANICS; KERATOCONUS; NONCONTACT; STRAIN; PROBE; OCT;
D O I
10.3389/fbioe.2023.1272097
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Purpose: Corneal cross-linking (CXL) has recently been used with promising results to positively affect corneal refractive power in the treatment of hyperopia and mild myopia. However, understanding and predicting the optomechanical changes induced by this procedure are challenging.Methods: We applied ambient pressure modulation based optical coherence elastography (OCE) to quantify the refractive and mechanical effects of patterned CXL and their relationship to energy delivered during the treatment on porcine corneas. Three different patterned treatments were performed, designed according to Zernike polynomial functions (circle, astigmatism, coma). In addition, three different irradiation protocols were analyzed: standard Dresden CXL (fluence of 5.4 J/cm(2)), accelerated CXL (fluence of 5.4 J/cm(2)), and high-fluence CXL (fluence of 16.2 J/cm(2)). The axial strain distribution in the stroma induced by ocular inflation (Delta p = 30 mmHg) was quantified, maps of the anterior sagittal curvature were constructed and cylindrical refraction was assessed.Results: Thirty minutes after CXL, there was a statistically significant increase in axial strain amplitude (p < 0.050) and a reduction in sagittal curvature (p < 0.050) in the regions treated with all irradiation patterns compared to the non-irradiated ones. Thirty-6 hours later, the non-irradiated regions showed compressive strains, while the axial strain in the CXL-treated regions was close to zero, and the reduction in sagittal curvature observed 30 minutes after the treatment was maintained. The Dresden CXL and accelerated CXL produced comparable amounts of stiffening and refractive changes (p = 0.856), while high-fluence CXL produced the strongest response in terms of axial strain (6.9 parts per thousand +/- 1.9 parts per thousand) and refractive correction (3.4 +/- 0.9 D). Tripling the energy administered during CXL resulted in a 2.4-fold increase in the resulting refractive correction.Conclusion: OCE showed that refractive changes and alterations in corneal biomechanics are directly related. A patient-specific selection of both, the administered UV fluence and the irradiation pattern during CXL is promising to allow customized photorefractive corrections in the future.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Corneal Collagen Cross-linking
    Stulting, R. Doyle
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 154 (03) : 423 - 424
  • [32] Complications of corneal cross-linking
    Seiler, T. G.
    Schmidinger, G.
    Fischinger, I.
    Koller, T.
    Seiler, T.
    OPHTHALMOLOGE, 2013, 110 (07): : 639 - 644
  • [33] RIBOFLAVIN FOR CORNEAL CROSS-LINKING
    O'Brart, D. P. S.
    DRUGS OF TODAY, 2016, 52 (06) : 331 - 346
  • [34] Corneal cross-linking - a review
    Meek, Keith M.
    Hayes, Sally
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2013, 33 (02) : 78 - 93
  • [35] Use of Anterior Segment Optical Coherence Tomography to Study Corneal Changes After Collagen Cross-linking
    Doors, Muriel
    Tahzib, Nayyirih G.
    Eggink, Fred A.
    Berendschot, Tos T. J. M.
    Webers, Carroll A. B.
    Nuijts, Rudy M. M. A.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (06) : 844 - 851
  • [36] Effect of fluence levels on prophylactic corneal cross-linking for laser in situ keratomileusis and transepithelial photorefractive keratectomy
    Lu, Nan-Ji
    Hafezi, Farhad
    Torres-Netto, Emilio A.
    Assaf, Jad F.
    Aslanides, Ioannis M.
    Awwad, Shady T.
    Cui, Le-Le
    Koppen, Carina
    ACTA OPHTHALMOLOGICA, 2023, 101 (02) : E185 - E196
  • [37] Efficacy of corneal cross-linking for the treatment of keratoconus
    Touboul, D.
    Robinet-Perrin, A.
    Fournie, P.
    Malecaze, F.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2016, 39 (03): : 308 - 314
  • [38] Corneal collagen cross-linking: ectasia and beyond
    Suri, Kunal
    Hammersmith, Kristin M.
    Nagra, Parveen K.
    CURRENT OPINION IN OPHTHALMOLOGY, 2012, 23 (04) : 280 - 287
  • [39] Design and implementation of optical system for corneal cross-linking device
    Zheng T.-L.
    Fu W.-W.
    Zhu H.-L.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2019, 27 (06): : 1286 - 1292
  • [40] Corneal Cross-Linking for Brittle Cornea Syndrome
    Kaufmann, Claude
    Schubiger, Gregor
    Thiel, Michael A.
    CORNEA, 2015, 34 (10) : 1326 - 1328