关键词
Proper orthogonal decomposition; Model order reduction; Finite element analysis; Transcatheter aortic valve replacement; Predictive computational modeling; BIOMECHANICAL INTERACTION; IMPLANTATION; IMPACT; HEMODYNAMICS; COREVALVE; OUTCOMES;
D O I
10.1007/s10439-023-03360-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Computational modeling can be a critical tool to predict deployment behavior for transcatheter aortic valve replacement (TAVR) in patients with aortic stenosis. However, due to the mechanical complexity of the aortic valve and the multiphysics nature of the problem, described by partial differential equations (PDEs), traditional finite element (FE) modeling of TAVR deployment is computationally expensive. In this preliminary study, a PDEs-based reduced order modeling (ROM) framework is introduced for rapidly simulating structural deformation of the Medtronic Evolut R valve stent frame. Using fifteen probing points from an Evolut model with parametrized loads enforced, 105 FE simulations were performed in the so-called offline phase, creating a snapshot library. The library was used in the online phase of the ROM for a new set of applied loads via the proper orthogonal decomposition-Galerkin (POD-Galerkin) approach. Simulations of small radial deformations of the Evolut stent frame were performed and compared to full order model (FOM) solutions. Linear elastic and hyperelastic constitutive models in steady and unsteady regimes were implemented within the ROM. Since the original POD-Galerkin method is formulated for linear problems, specific methods for the nonlinear terms in the hyperelastic case were employed, namely, the Discrete Empirical Interpolation Method. The ROM solutions were in strong agreement with the FOM in all numerical experiments, with a speed-up of at least 92% in CPU Time. This framework serves as a first step toward real-time predictive models for TAVR deployment simulations.
引用
收藏
页码:208 / 225
页数:18
相关论文
共 50 条
  • [41] Reduced-Order Model of a Time-Trial Cyclist Helmet for Aerodynamic Optimization Through Mesh Morphing and Enhanced with Real-Time Interactive Visualization
    Di Meo, E.
    Lopez, A.
    Groth, C.
    Biancolini, M. E.
    Valentini, P. P.
    FLUIDS, 2024, 9 (12)
  • [42] A Systematic Review of Real-Time Medical Simulations with Soft-Tissue Deformation: Computational Approaches, Interaction Devices, System Architectures, and Clinical Validations
    Nguyen, Tan-Nhu
    Ho Ba Tho, Marie-Christine
    Dao, Tien-Tuan
    APPLIED BIONICS AND BIOMECHANICS, 2020, 2020 (2020)
  • [43] Device Landing Zone Calcification Predicts Significant Paravalvular Regurgitation after Transcatheter Aortic Valve Replacement: A Real Time Three-Dimensional Transesophageal Echocardiography Study
    Mihara, Hirotsugu
    Shibayama, Kentaro
    Harada, Kenji
    Berdejo, Javier
    Itabashi, Yuji
    Makkar, Raj R.
    Shiota, Takahiro
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (05): : E142 - E144
  • [44] POD-Enhanced Deep Learning-Based Reduced Order Models for the Real-Time Simulation of Cardiac Electrophysiology in the Left Atrium
    Fresca, Stefania
    Manzoni, Andrea
    Dede, Luca
    Quarteroni, Alfio
    FRONTIERS IN PHYSIOLOGY, 2021, 12
  • [45] Co-rotational Reduced Order Kalman Filter Finite Element Method for the Real-time Implementation of Large-scale Structural Models
    Rasheed, Bismi
    Pedersen, Morten Dinhoff
    Schaathun, Hans Georg
    IFAC PAPERSONLINE, 2023, 56 (02): : 10198 - 10203
  • [46] International journal of computational fluid dynamics real-time prediction of unsteady flow based on POD reduced-order model and particle filter
    Kikuchi, Ryota
    Misaka, Takashi
    Obayashi, Shigeru
    INTERNATIONAL JOURNAL OF COMPUTATIONAL FLUID DYNAMICS, 2016, 30 (04) : 285 - 306
  • [47] Transapical aortic valve replacement under real-time magnetic resonance imaging guidance: experimental results with balloon-expandable and self-expanding stents
    Horvath, Keith A.
    Mazilu, Dumitru
    Kocaturk, Ozgur
    Li, Ming
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 39 (06) : 822 - 828
  • [48] Casting hybrid twin: physics-based reduced order models enriched with data-driven models enabling the highest accuracy in real-time
    Amine Ammar
    Mariem Ben Saada
    Elias Cueto
    Francisco Chinesta
    International Journal of Material Forming, 2024, 17
  • [49] Casting hybrid twin: physics-based reduced order models enriched with data-driven models enabling the highest accuracy in real-time
    Ammar, Amine
    Ben Saada, Mariem
    Cueto, Elias
    Chinesta, Francisco
    INTERNATIONAL JOURNAL OF MATERIAL FORMING, 2024, 17 (02)
  • [50] Parallel spatiotemporal order-reduced Gaussian process for dynamic full-field multi-physics prediction of hypervelocity collisions in real-time with limited data
    Wang, Zhuosen
    Cheng, Yunguo
    Ding, Chensen
    COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2025, 438