Comparison of definitions of coronary artery reference sizes and effects on stent selection and evaluation of stent expansion

被引:2
|
作者
Andreasen, Lene Nyhus [1 ,2 ]
Christiansen, Evald Hoj [1 ]
Mogensen, Lone Juul Hune [1 ]
Holm, Niels Ramsing [1 ]
机构
[1] Aarhus Univ Hosp, Dept Cardiol, Aarhus, Denmark
[2] Aarhus Univ Hosp, Palle Juul Jensens Blvd 99, DK-8200 Aarhus, Denmark
关键词
Coronary reference estimations; Optical coherence tomography; Intervascular imaging; Stent expansion; OPTICAL COHERENCE TOMOGRAPHY; INTRAVASCULAR-ULTRASOUND; IMPLANTATION; ANGIOGRAPHY; TRIAL; IVUS; INTERVENTION; GUIDANCE; LESIONS; PREDICTORS;
D O I
10.1007/s10554-023-02890-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Accurate determination of coronary reference size is essential for optimal stent selection and evaluation of stent expansion during percutaneous coronary intervention (PCI). Several approaches for reference size estimation have been published with no universal agreement. The aim of this study was to investigate if potential differences in coronary reference size estimation lead to differences in stent and balloon selection and in detection of stent under expansion. Definitions for coronary reference size estimation, stent size selection, and stent expansion were identified in 17 randomized controlled trials. The identified methods were applied in a population of 32 clinical cases. Reference size estimates ranged up to 1.35mm, and indicated nominal stent size ranged up to 1.0 mm in the same case depending on method. Mean relative stent expansion ranged from 54 & PLUSMN;12% to mean 100 & PLUSMN;29% depending on the applied reference method. Choice of method for reference size estimation using intravascular imaging may influence stent selection and greatly affects evaluation of post-PCI stent expansion.
引用
收藏
页码:1825 / 1837
页数:13
相关论文
共 50 条
  • [41] Treatment of Sirolimus-Eluting Stent Restenosis: Additional Stent, Balloon Angioplasty, and Coronary Artery Bypass Graft
    Ishikawa, Kiyotake
    Aoyama, Yutaka
    Kato, Katsuhiro
    Tanaka, Akihito
    Hiramatsu, Mizuho
    Ajioka, Masayoshi
    Kamiya, Haruo
    Tanaka, Toshikazu
    Hirayama, Haruo
    JOURNAL OF CARDIAC SURGERY, 2013, 28 (02) : 97 - 101
  • [42] Increased cholesterol absorption is associated with In-stent-restenosis after stent implantation for stable coronary artery disease
    Otto, Sylvia
    Luetjohann, Dieter
    Kerksiek, Anja
    Friedrichs, Silvia
    Schulze, Paul Christian
    Moebius-Winkler, Sven
    Porner, Tudor C.
    Weingaertner, Oliver
    STEROIDS, 2022, 187
  • [43] Drug-eluting stent implantation for coronary artery disease: current stents and a comparison with bypass surgery
    Head, Stuart J.
    Bogers, Ad J. J. C.
    Kappetein, A. Pieter
    CURRENT OPINION IN PHARMACOLOGY, 2012, 12 (02) : 147 - 154
  • [44] Three-dimensional intravascular ultrasound evaluation of carina and plaque shift at the distal left main coronary artery bifurcation after treatment with a one-stent cross-over technique
    Xiu, Jiancheng
    Choi, So-Yeon
    Mintz, Gary S.
    Araki, Hiroshi
    Masuda, Naoki
    Morino, Yoshihiro
    Sonoda, Shinjo
    Tahk, Seung Jea
    Ochiai, Masahiko
    Maehara, Akiko
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (07) : 1142 - 1149
  • [45] Frequency and impact of bleeding in elective coronary stent clinical trials-Utility of three commonly used definitions
    Fleming, Lisa M.
    Novack, Victor
    Novack, Lena
    Cohen, Sidney A.
    Negoita, Manuela
    Cutlip, Donald E.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 80 (02) : E23 - E29
  • [46] Coronary artery stent fracture with in-stent restenosis and aneurysm formation: Diagnosis and successful treatment with graft stent implantation
    Stambuk, Kresimir
    Pavlovic, Nikola
    Gabric, Ivo Darko
    Krcmar, Tomislav
    Trbusic, Matias
    Manola, Sime
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 148 (02) : 253 - 255
  • [47] Clinical Outcomes Following Covered Stent for the Treatment of Coronary Artery Perforation
    Lee, Wei-Chieh
    Hsueh, Shu-Kai
    Fang, Chih-Yuan
    Wu, Chiung-Jen
    Hang, Chi-Ling
    Fang, Hsiu-Yu
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2016, 29 (06) : 569 - 575
  • [48] Impact of drug-eluting stent selection on long-term clinical outcomes in patients treated for unprotected left main coronary artery disease: The sirolimus vs paclitaxel drug-eluting stent for left main registry (SP-DELFT)
    Meliga, E.
    Garcia-Garcia, H. M.
    Valgimigli, M.
    Chieffo, A.
    Biondi-Zoccai, G.
    Maree, A. O.
    Gonzalo, N.
    Cook, S.
    Marra, S.
    Moretti, C.
    De Servi, S.
    Palacios, I. F.
    Windecker, S.
    van Domburg, R.
    Colombo, A.
    Sheiban, I.
    Serruys, P. W.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 137 (01) : 16 - 21
  • [49] Artifacts in intravascular ultrasound imaging during coronary artery stent implantation
    Finet, G
    Cachard, C
    Delachartre, P
    Maurincomme, E
    Beaune, J
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (06) : 793 - 802
  • [50] Fracture of coronary artery sirolimus eluting stent with formation of four aneurysms
    D'Amico, Maurizio
    Frisenda, Valeria
    Conrotto, Federico
    Pennone, Mauro
    Scacciatella, Paolo
    Marra, Sebastiano
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2015, 16 : S125 - S129