Reliability of Measurements Using Ocular Response Analyzer as a Screening Tonometer and Corneal Hysteresis Values in the Presence or Absence of Glaucomatous Changes in Fundus

被引:1
作者
Maruyama, Katsuhiko [1 ,2 ]
Sugiura, Natsumi [1 ]
Taki, Toshie [1 ]
机构
[1] Yashio Maruyama Eye Clin, Saitama, Japan
[2] Yashio Maruyama Eye Clin, 2F,5-1-15,Oze, Yashio, Saitama 3400822, Japan
关键词
Ocular Response Analyzer; reliability; waveform score; intraocular pressure; corneal hysteresis; glaucoma; WAVE-FORM SCORE; RISK-FACTOR; THICKNESS;
D O I
10.1097/IJG.0000000000002312
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Precis: Use of the Ocular Response Analyzer (ORA) as a screening tonometer in clinical practice yielded reliable measurements in over 80% of eyes screened. Including corneal hysteresis (CH) data in screening may improve the accuracy of glaucoma detection. Purpose: To examine measurement reliability when the ORA is used as a screening tonometer, and to compare CH measurements in eyes with and those without glaucomatous changes in the fundus. Patients and Methods: 1488 eyes of 747 patients (mean age: 53.5 +/- 20.4 y, range: 6-94 y) underwent intraocular pressure (IOP) measurement using ORA as screening. The percentage of eyes with a waveform score >= 6, the recommended threshold indicating reliability, was calculated. Eyes that had waveform score >= 6 and had undergone fundus photography and optical coherence tomography were assessed for the presence or absence of glaucomatous changes in fundus from optical coherence tomography and fundus images, and CH was compared between the 2 groups. Results: Mean +/- SD (range) of ORA measurements were: Goldmann-correlated IOP 14.9 +/- 4.8 (1.0-63.2) mm Hg, corneal-compensated IOP 16.2 +/- 4.7 (3.2-73.6) mm Hg, CH 9.7 +/- 1.5 (0.0-20.6) mm Hg, and waveform score 7.3 +/- 1.5 (0.1-9.7). Eighty-four percent of eyes had a waveform score >= 6. Among 192 eyes (127 patients, aged 53.5 +/- 18.0 y) with waveform score >= 6 and evaluable for glaucomatous changes in the fundus, 53 eyes were determined as positive and 139 eyes as negative. CH was 9.6 +/- 1.4 (6.8-13.3) mm Hg in the positive group and 10.2 +/- 1.2 (6.9-13.3) mm Hg in the negative group, and was significantly lower in the positive group (P=0.003). Conclusion: When using ORA as a screening tonometer, reliable results were obtained in similar to 80% of the eyes. CH was lower in the glaucomatous change-positive group compared with the glaucomatous change-negative group, but the ranges overlapped between the 2 groups.
引用
收藏
页码:183 / 188
页数:6
相关论文
共 19 条
[1]   Corneal hysteresis measured with the Ocular Response Analyzer® in normal and glaucomatous eyes [J].
Abitbol, Olivia ;
Bouden, Jihene ;
Doan, Serge ;
Hoang-Xuan, Thanh ;
Gatinel, Damien .
ACTA OPHTHALMOLOGICA, 2010, 88 (01) :116-119
[2]   Biomechanical Glaucoma Factor and Corneal Hysteresis in Treated Primary Open-Angle Glaucoma and Their Associations With Visual Field Progression [J].
Aoki, Shuichiro ;
Miki, Atsuya ;
Omoto, Takashi ;
Fujino, Yuri ;
Matsuura, Masato ;
Murata, Hiroshi ;
Asaoka, Ryo .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (07)
[3]   Measuring corneal hysteresis: threshold estimation of the waveform score from the Ocular Response Analyzer [J].
Ayala, Marcelo ;
Chen, Enping .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (12) :1803-1806
[4]   Central corneal thickness and corneal hysteresis associated with glaucoma damage [J].
Congdon, NG ;
Broman, AT ;
Bandeen-Roche, K ;
Grover, D ;
Quigley, HA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (05) :868-875
[5]   Lower Corneal Hysteresis is Associated With More Rapid Glaucomatous Visual Field Progression [J].
De Moraes, Carlos Gustavo V. ;
Hill, Victoria ;
Tello, Celso ;
Liebmann, Jeffrey M. ;
Ritch, Robert .
JOURNAL OF GLAUCOMA, 2012, 21 (04) :209-213
[6]   Corneal biomechanics measured with the ocular response analyser in patients with unilateral open-angle glaucoma [J].
Hirneiss, Christoph ;
Neubauer, Aljoscha S. ;
Yu, Alice ;
Kampik, Anselm ;
Kernt, Marcus .
ACTA OPHTHALMOLOGICA, 2011, 89 (02) :E189-E192
[7]   Corneal Hysteresis and Rates of Neuroretinal Rim Change in Glaucoma [J].
Jammal, Alessandro A. ;
Medeiros, Felipe A. .
OPHTHALMOLOGY GLAUCOMA, 2022, 5 (05) :483-489
[8]   Relationship Between Corneal Biomechanical Properties, Central Corneal Thickness, and Intraocular Pressure Across the Spectrum of Glaucoma [J].
Kaushik, Sushmita ;
Pandav, Surinder Singh ;
Banger, Anupam ;
Aggarwal, Kanika ;
Gupta, Amod .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 153 (05) :840-849
[9]   The Usefulness of Waveform Score from the Ocular Response Analyzer [J].
Lam, Andrew K. C. ;
Chen, Davie ;
Tse, Jimmy .
OPTOMETRY AND VISION SCIENCE, 2010, 87 (03) :195-199
[10]   Temporal Raphe Sign for Discrimination of Glaucoma from Optic Neuropathy in Eyes with Macular Ganglion Cell-Inner Plexiform Layer Thinning [J].
Lee, Jinho ;
Kim, Young Kook ;
Ha, Ahnul ;
Kim, Yong Woo ;
Back, Sung Uk ;
Kim, Jin-Soo ;
Lee, Haeng Jin ;
Kim, Dai Woo ;
Jeoung, Jin Wook ;
Kim, Seong-Joon ;
Park, Ki Ho .
OPHTHALMOLOGY, 2019, 126 (08) :1131-1139