Automated glycemic control with a bionic pancreas for type 1 diabetes mellitus: A systematic review and meta-analysis

被引:3
作者
Oktavian, Puguh [1 ]
Budi, David Setyo [1 ]
Wibowo, Idznika Nurannisa [1 ]
Rusuldi, Reyna Cesariyani Rahmadianti [1 ]
Kusumawardhani, Avianita Dewi [1 ]
Wafa, Ifan Ali [1 ]
Rahman, Hamzah Rafly [1 ]
Pratama, Nando Reza [2 ]
Mudjanarko, Sony Wibisono [3 ,4 ]
机构
[1] Univ Airlangga, Fac Med, Surabaya, Indonesia
[2] Univ Oxford, Nuffield Dept Med, Oxford, England
[3] Univ Airlangga, Dr Soetomo Gen Acad Hosp, Fac Med, Div Endocrinol Metab & Diabet,Dept Internal Med, Surabaya, Indonesia
[4] Univ Airlangga, Fac Med, Dept Internal Med, Div Endocrinol Metab & Diabet, Jl Mayjen Prof Dr Moestopo 47, Surabaya 60131, Indonesia
关键词
Bionic pancreas; Automatic glycemic control; Diabetes mellitus; Continuous glucose monitoring; Time-in-range; INSULIN-ONLY CONFIGURATION; PUMP THERAPY; ADULTS; GLUCOSE;
D O I
10.1016/j.dsx.2023.102847
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aims: The use of a bionic pancreas with automated insulin delivery systems to prevent complications of diabetes mellitus shows conflicting results. We aimed to comprehensively discuss the potential use of a bionic pancreas in patients with type 1 diabetes (T1D).Methods: A systematic database search was conducted on October 24, 2022, for articles investigating the use of a bionic pancreas in patients with T1D. The hemoglobin A1c (HbA1c) level, mean glucose level, glucose coefficient of variability, time-in-range (TIR), and adverse events were investigated.Results: Nine studies were included in this review. The data from these studies suggested that the use of a bionic pancreas could reduce the HbA1c (mean difference [MD] =-0.40% [95% confidence interval {CI} =-0.59 to-0.21], I-2 = 0%, p < 0.0001) and mean glucose levels (MD =-21.06 [95% CI =-24.66 to-17.46], I-2 = 45%, p < 0.00001) and improve the TIR (MD = 14.41% [95% CI = 10.99 to 17.83], I-2 = 60%, p < 0.00001). The most common adverse events reported were nausea and vomiting.Conclusions: The use of a bionic pancreas shows potential in preventing complications of T1D by improving the TIR and decreasing the HbA1c and mean glucose levels. Furthermore, serious adverse events with the use of a bionic pancreas and standard of care show insignificant results, suggesting a good safety profile.
引用
收藏
页数:9
相关论文
共 31 条
[1]  
[Anonymous], 2008, Clin Diabetes, DOI [10.2337/diaclin.26.2.77, DOI 10.2337/DIACLIN.26.2.77]
[2]   Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range [J].
Battelino, Tadej ;
Danne, Thomas ;
Bergenstal, Richard M. ;
Amiel, Stephanie A. ;
Beck, Roy ;
Biester, Torben ;
Bosi, Emanuele ;
Buckingham, Bruce A. ;
Cefalu, William T. ;
Close, Kelly L. ;
Cobelli, Claudio ;
Dassau, Eyal ;
DeVries, J. Hans ;
Donaghue, Kim C. ;
Dovc, Klemen ;
Doyle, Francis J. ;
Garg, Satish ;
Grunberger, George ;
Heller, Simon ;
Heinemann, Lutz ;
Hirsch, Irl B. ;
Hovorka, Roman ;
Jia, Weiping ;
Kordonouri, Olga ;
Kovatchev, Boris ;
Kowalski, Aaron ;
Laffel, Lori ;
Levine, Brian ;
Mayorov, Alexander ;
Mathieu, Chantal ;
Murphy, Helen R. ;
Nimri, Revital ;
Norgaard, Kirsten ;
Parkin, Christopher G. ;
Renard, Eric ;
Rodbard, David ;
Saboo, Banshi ;
Schatz, Desmond ;
Stoner, Keaton ;
Urakami, Tatsuiko ;
Weinzimer, Stuart A. ;
Phillip, Moshe .
DIABETES CARE, 2019, 42 (08) :1593-1603
[3]   A Multicenter Randomized Trial Evaluating Fast-Acting Insulin Aspart in the Bionic Pancreas in Adults with Type 1 Diabetes [J].
Beck, Roy W. ;
Russell, Steven J. ;
Damiano, Edward R. ;
El-Khatib, Firas H. ;
Ruedy, Katrina J. ;
Balliro, Courtney ;
Li, Zoey ;
Calhoun, Peter .
DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (10) :681-696
[4]   Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes [J].
Bergenstal, Richard M. ;
Tamborlane, William V. ;
Ahmann, Andrew ;
Buse, John B. ;
Dailey, George ;
Davis, Stephen N. ;
Joyce, Carol ;
Peoples, Tim ;
Perkins, Bruce A. ;
Welsh, John B. ;
Willi, Steven M. ;
Wood, Michael A. .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (04) :311-320
[5]  
Castle Jessica R, 2010, J Diabetes Sci Technol, V4, P1305
[6]   Interstitial Fluid Glucose Is Not Just a Shifted-in-Time but a Distorted Mirror of Blood Glucose: Insight from an In Silico Study [J].
Cobelli, Claudio ;
Schiavon, Michele ;
Man, Chiara Dalla ;
Basu, Ananda ;
Basu, Rita .
DIABETES TECHNOLOGY & THERAPEUTICS, 2016, 18 (08) :505-511
[7]   Hypoglycaemia: The limiting factor in the glycaemic management of Type I and Type II Diabetes [J].
Cryer, PE .
DIABETOLOGIA, 2002, 45 (07) :937-948
[8]   Quantification of the Glycemic Response to Microdoses of Subcutaneous Glucagon at Varying Insulin Levels [J].
El Youssef, Joseph ;
Castle, Jessica R. ;
Bakhtiani, Parkash A. ;
Haidar, Ahmad ;
Branigan, Deborah L. ;
Breen, Matthew ;
Ward, W. Kenneth .
DIABETES CARE, 2014, 37 (11) :3054-3060
[9]   Home use of a bihormonal bionic pancreas versus insulin pump therapy in adults with type 1 diabetes: a multicentre randomised crossover trial [J].
El-Khatib, Firas H. ;
Balliro, Courtney ;
Hillard, Mallory A. ;
Magyar, Kendra L. ;
Ekhlaspour, Laya ;
Sinha, Manasi ;
Mondesir, Debbie ;
Esmaeili, Aryan ;
Hartigan, Celia ;
Thompson, Michael J. ;
Malkani, Samir ;
Lock, J. Paul ;
Harlan, David M. ;
Clinton, Paula ;
Frank, Eliana ;
Wilson, Darrell M. ;
DeSalvo, Daniel ;
Norlander, Lisa ;
Ly, Trang ;
Buckingham, Bruce A. ;
Diner, Jamie ;
Dezube, Milana ;
Young, Laura A. ;
Goley, April ;
Kirkman, M. Sue ;
Buse, John B. ;
Zheng, Hui ;
Selagamsetty, Rajendranath R. ;
Damiano, Edward R. ;
Russell, Steven J. .
LANCET, 2017, 389 (10067) :369-380
[10]   A Bihormonal Closed-Loop Artificial Pancreas for Type 1 Diabetes [J].
El-Khatib, Firas H. ;
Russell, Steven J. ;
Nathan, David M. ;
Sutherlin, Robert G. ;
Damiano, Edward R. .
SCIENCE TRANSLATIONAL MEDICINE, 2010, 2 (27) :27ra27