Vascular complications of ProGlide versus Prostar in transcatheter aortic valve replacement (TAVR) procedures: meta-analysis

被引:3
作者
Xiang, Yuwei [1 ]
Chen, Chen [2 ]
Zhao, Jichun [1 ]
Ma, Yukui [1 ]
Huang, Bin [1 ]
Wu, Zhoupeng [1 ]
机构
[1] Sichuan Univ, West China Hosp, Div Vasc Surg, Dept Gen Surg, 37 Guo Xue Alley, Chengdu 610041, Sichuan, Peoples R China
[2] Sichuan Univ, West China Hosp, Div Cardiol, Chengdu, Peoples R China
基金
中国博士后科学基金;
关键词
MEDIATED CLOSURE DEVICES; ACCESS SITE CLOSURE; END-POINT DEFINITIONS; SUTURE TECHNIQUE; ANEURYSM REPAIR; OUTCOMES; IMPLANTATION; MULTICENTER; HEMOSTASIS; REGISTRY;
D O I
10.1093/bjsopen/zrad061
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The aim of this study was to compare the vascular complications of ProGlide and Prostar in percutaneous transfemoral transcatheter aortic valve replacement. Methods: Electronic databases were searched in July 2022 for studies that compared the vascular complications of ProGlide and Prostar for percutaneous closure in transcatheter aortic valve replacement. The primary outcome was major vascular complications and the secondary outcomes were minor vascular complications, types of access-site vascular complications, device failure, and additional intervention. Estimates of relative effects were pooled to generate ORs and their 95 per cent c.i. using a random-effects model. The risk of bias in non-randomized comparative studies was assessed using the Risk Of Bias In Non-randomized Studies - of Interventions ('ROBINS-I') tool. Results: Nine studies were identified and a total of 7529 patients were included. Among them, 4144 patients received ProGlide and 3385 received Prostar. The pooled data showed that the risk of major vascular complications was significantly lower with ProGlide versus Prostar (OR 0.50, 95 per cent c.i. 0.32 to 0.78). Regarding the types of vascular complications, vascular trauma was the most common complication and the risk was similar between groups (OR 1.02, 95 per cent c.i. 0.55 to 1.91). ProGlide had a lower risk of bleeding complications (OR 0.46, 95 per cent c.i. 0.22 to 0.94), but a higher risk of ischaemia complications (OR 1.90, 95 per cent c.i. 1.10 to 3.27). The risk of device failure was lower in the ProGlide group (OR 0.45, 95 per cent c.i. 0.21 to 0.95). Both groups had a similar risk of having additional interventions for vascular complications (OR 1.02, 95 per cent c.i. 0.75 to 1.39). The use of ProGlide was associated with a lower risk of additional surgical treatments (OR 0.52, 95 per cent c.i. 0.34 to 0.80), but a higher risk of endovascular treatments (OR 2.69, 95 per cent c.i. 1.29 to 5.63). Conclusion: In percutaneous transfemoral transcatheter aortic valve replacement procedures, ProGlide has superior safety and efficacy when compared with Prostar; it is associated with fewer major vascular complications and device failures. The vascular complications of ProGlide are more likely to be dealt with using endovascular treatments than surgical treatments.
引用
收藏
页数:9
相关论文
共 44 条
[1]  
Akyüz AR, 2022, HERZ, V47, P449, DOI 10.1007/s00059-021-05069-4
[2]  
[Anonymous], ANN THORAC SURG
[3]   Comparison of suture-based vascular closure devices in transfemoral transcatheter aortic valve implantation [J].
Barbanti, Marco ;
Capranzano, Piera ;
Ohno, Yohei ;
Gulino, Simona ;
Sgroi, Carmelo ;
Imme, Sebastiano ;
Tamburino, Claudia ;
Cannata, Stefano ;
Patane, Martina ;
Di Stefano, Daniele ;
Todaro, Denise ;
Di Simone, Emanuela ;
Deste, Wanda ;
Gargiulo, Giuseppe ;
Capodanno, Davide ;
Grasso, Carmelo ;
Tamburino, Corrado .
EUROINTERVENTION, 2015, 11 (06) :690-697
[4]   Comparison of vascular closure devices for access site closure after transfemoral aortic valve implantation [J].
Barbash, Israel M. ;
Barbanti, Marco ;
Webb, John ;
De Nicolas, Javier Molina-Martin ;
Abramowitz, Yigal ;
Latib, Azeem ;
Nguyen, Caroline ;
Deuschl, Florian ;
Segev, Amit ;
Sideris, Konstantinos ;
Buccheri, Sergio ;
Simonato, Matheus ;
Della Rosa, Francesco ;
Tamburino, Corrado ;
Jilaihawi, Hasan ;
Miyazaki, Tadashi ;
Himbert, Dominique ;
Schofer, Niklas ;
Guetta, Victor ;
Bleiziffer, Sabine ;
Tchetche, Didier ;
Imme, Sebastiano ;
Makkar, Raj R. ;
Vahanian, Alec ;
Treede, Hendrik ;
Lange, Ruediger ;
Colombo, Antonio ;
Dvir, Danny .
EUROPEAN HEART JOURNAL, 2015, 36 (47) :3370-3379
[5]   Predicting the learning curve and failures of total percutaneous endovascular aortic aneurysm repair [J].
Bechara, Carlos F. ;
Barshes, Neal R. ;
Pisimisis, George ;
Chen, Huiting ;
Pak, Taemee ;
Lin, Peter H. ;
Kougias, Panagiotis .
JOURNAL OF VASCULAR SURGERY, 2013, 57 (01) :72-76
[6]   Efficacy and Safety of ProGlide Versus Prostar XL Vascular Closure Devices in Transcatheter Aortic Valve Replacement: The RISPEVA Registry [J].
Berti, Sergio ;
Bedogni, Francesco ;
Giordano, Arturo ;
Petronio, Anna S. ;
Iadanza, Alessandro ;
Bartorelli, Antonio L. ;
Reimers, Bernard ;
Spaccarotella, Carmen ;
Trani, Carlo ;
Attisano, Tiziana ;
Marella Cenname, Angela ;
Sardella, Gennaro ;
Bonmassari, Roberto ;
Medda, Massimo ;
Tomai, Fabrizio ;
Tarantini, Giuseppe ;
Navarese, Eliano P. .
JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2020, 9 (21)
[7]   Propensity-Matched Comparisons of Clinical Outcomes After Transapical or Transfemoral Transcatheter Aortic Valve Replacement A Placement of Aortic Transcatheter Valves (PARTNER)-I Trial Substudy [J].
Blackstone, Eugene H. ;
Suri, Rakesh M. ;
Rajeswaran, Jeevanantham ;
Babaliaros, Vasilis ;
Douglas, Pamela S. ;
Fearon, William F. ;
Miller, D. Craig ;
Hahn, Rebecca T. ;
Kapadia, Samir ;
Kirtane, Ajay J. ;
Kodali, Susheel K. ;
Mack, Michael ;
Szeto, Wilson Y. ;
Thourani, Vinod H. ;
Tuzcu, E. Murat ;
Williams, Mathew R. ;
Akin, Jodi J. ;
Leon, Martin B. ;
Svensson, Lars G. .
CIRCULATION, 2015, 131 (22) :1989-+
[8]   STS-ACC TVT Registry of Transcatheter Aortic Valve Replacement [J].
Carroll, John D. ;
Mack, Michael J. ;
Vemulapalli, Sreekanth ;
Herrmann, Howard C. ;
Gleason, Thomas G. ;
Hanzel, George ;
Deeb, G. Michael ;
Thourani, Vinod H. ;
Cohen, David J. ;
Desai, Nimesh ;
Kirtane, Ajay J. ;
Fitzgerald, Susan ;
Michaels, Joan ;
Krohn, Carole ;
Masoudi, Frederick A. ;
Brindis, Ralph G. ;
Bavaria, Joseph E. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (21) :2492-2516
[9]   Real-world experience of suture-based closure devices: Insights from the FDA Manufacturer and User Facility Device Experience [J].
Case, Brian C. ;
Kumar, Sant ;
Yerasi, Charan ;
Forrestal, Brian J. ;
Musallam, Anees ;
Chezar-Azerrad, Chava ;
Khalid, Nauman ;
Shlofmitz, Evan ;
Chen, Yuefeng ;
Khan, Jaffar M. ;
Satler, Lowell F. ;
Ben-Dor, Itsik ;
Hashim, Hayder ;
Bernardo, Nelson L. ;
Rogers, Toby ;
Waksman, Ron .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2021, 98 (03) :572-577
[10]  
Cox Tiffany, 2015, Surg Technol Int, V27, P32