Comparison of Primary Stability of Two Different Implants Designs-A Prospective Clinical Study

被引:0
作者
Sravanthi, A. Veena [1 ]
Manne, Prakash [1 ]
Surapaneni, Haragopal [1 ]
机构
[1] Sibar Inst Dent Sci, Dept Prosthodont, Guntur, Andhra Pradesh, India
关键词
Bone density; Osseointegration; Osteotomy; Torque values; TAPERED IMPLANTS; INSERTION TORQUE; REGIONS;
D O I
10.7860/JCDR/2023/59056.17248
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Any implant treatment must begin with successful implant integration. The effectiveness of implant osseointegration is determined by various factors, including implant design, implant diameter and density, and surgical technique. Osseointegration is dependent on implant design. Aim: To assess the primary stability of tapered and cylindrical implants by using Resonance Frequency Analysis (RFA) and Insertion Torque Values (ITV). Materials and Methods: This in-vivo, prospective clinical study was conducted in the Department of Prosthodontics at Sibar Institute of Dental Sciences, Guntur, Andhra Pradesh, India in the month of November 2019. Twenty patients were selected for the study. Tapered Bioline implants (Bioline Dental GmbH & Co. KG -Germany) were spaced in 10 patients (group 1) and cylindrical Bioline implants (Bioline Dental GmbH & Co. KG-Germany) in the other 10 patients (group 2). For both implant designs, primary stability was assessed immediately after implant placement using RFA by Osstell Mentor and ITV by a torque wrench. Kolmogorov-Smirnov test, Shapiro-Wilk test were used for checking normality. Mann Whitney U test, Independent t tests, Spearman correlation tests were done by using software Statistical Package for Social Sciences (SPSS) Version 23.0. Results: The mean ISQ (Implant Stability Quotient) for tapered implants was 76.6 +/- 2.3, and for cylindrical implants mean ISQ is 59.75 +/- 4.2 (p-value < 0.001). The mean ITV for tapered implants was 43.5 +/- 2.58 Ncm, and for cylindrical implants, the mean ITV was 33 +/- 4.21 Ncm (p-value < 0.001). The correlation between ITV and RFA was 0.928 which was highly significant (p < 0.001**). Conclusion: Within the scope of this investigation, tapered implants showed better primary stability than cylindrical-shaped implants as determined by ISQ and insertion torque values. ITV and ISQ values showed a positive correlation in determining the primary stability of implants.
引用
收藏
页码:ZC16 / ZC19
页数:4
相关论文
共 18 条
[1]  
Bahat Oded, 2010, Clin Implant Dent Relat Res, V12 Suppl 1, pe2, DOI 10.1111/j.1708-8208.2010.00279.x
[2]  
BERGENDAL T, 1994, SWED DENT J, V18, P75
[3]   Influence of surgical technique, implant shape and diameter on the primary stability in cancellous bone [J].
Bilhan, H. ;
Geckili, O. ;
Mumcu, E. ;
Bozdag, E. ;
Sunbuloglu, E. ;
Kutay, O. .
JOURNAL OF ORAL REHABILITATION, 2010, 37 (12) :900-907
[4]  
do Vale Souza Joao Paulo, 2021, Eur J Dent, V15, P618, DOI [10.1055/s-0041-1725575, 10.1055/s-0041-1725575]
[5]   The Effects of Superficial Roughness and Design on the Primary Stability of Dental Implants [J].
dos Santos, Mychelle Vianna ;
Elias, Carlos Nelson ;
Cavalcanti Lima, Jose Henrique .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2011, 13 (03) :215-223
[6]   Primary stability and healing outcomes of apically tapered and straight implants placed into fresh extraction sockets. A pre-clinical in vivo study [J].
Ellis, Rebecca ;
Chen, Stephen ;
Davies, Helen ;
Fitzgerald, Wayne ;
Xu, Junhua ;
Darby, Ivan .
CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (08) :705-714
[7]  
George A, 2015, Alexandria Dental Journal, V40, P221, DOI [10.21608/adjalexu.2015.59156, 10.21608/adjalexu.2015.59156, DOI 10.21608/ADJALEXU.2015.59156]
[8]   Role of primary stability for successful osseointegration of dental implants: Factors of influence and evaluation [J].
Javed, Fawad ;
Ahmed, Hameeda Bashir ;
Crespi, Roberto ;
Romanos, Georgios E. .
INTERVENTIONAL MEDICINE AND APPLIED SCIENCE, 2013, 5 (04) :162-167
[9]   Effect of implant macro-design on primary stability: A prospective clinical study [J].
Lozano-Carrascal, Naroa ;
Salomo-Coll, Oscar ;
Gilabert-Cerda, Marta ;
Farre-Pages, Nuria ;
Gargallo-Albiol, Jordi ;
Hernandez-Alfaro, Federico .
MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2016, 21 (02) :E214-E221
[10]  
Menicucci G, 2012, INT J PROSTHODONT, V25, P465