Ten-year experience with sutureless Perceval bioprosthesis: single-centre analysis in 1157 implants

被引:9
作者
Concistre, Giovanni [1 ,2 ]
Bianchi, Giacomo [1 ]
Margaryan, Rafik [1 ]
Zancanaro, Edoardo [1 ]
Chiaramonti, Francesca [1 ]
Kallushi, Enkel [1 ]
Gasbarri, Tommaso [1 ]
Murzi, Michele [1 ]
Varone, Egidio [1 ]
Simeoni, Simone [1 ]
Leone, Alessandro [1 ]
Santarelli, Filippo [1 ]
Farneti, Pierandrea [1 ]
Solinas, Marco [1 ]
机构
[1] Fdn CNR G Monasterio, G Pasquinucci Heart Hosp, Dept Adult Cardiac Surg, Massa, Italy
[2] G Pasquinucci Heart Hosp, Dept Adult Cardiac Surg, Via Aurelia Sud, I-54100 Massa, Italy
关键词
aortic bioprosthesis; aortic valve disease; aortic valve surgery; minimally invasive surgery; AORTIC-VALVE-REPLACEMENT; TRANSCATHETER; MULTICENTER; PROSTHESIS; GUIDELINES; MORTALITY; OUTCOMES;
D O I
10.2459/JCM.0000000000001475
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
AimsWe describe long-term clinical and echocardiographic outcomes in the largest single-centre cohort of patients who underwent aortic valve replacement (AVR) with sutureless Perceval (CorCym, Italy) bioprosthesis.MethodsBetween March 2011 and March 2021, 1157 patients underwent AVR with Perceval bioprosthesis implantation. Mean age was 77 & PLUSMN; 6 years (range: 46-89 years) and mean EuroSCORE II was 6.7 & PLUSMN; 3.2% (range: 1.7-14.2%). Concomitant procedures were performed in 266 patients (23%).ResultsThirty-day mortality was 1.38% (16/1157). Eight hundred and twenty of 891 (92%) isolated AVRs underwent minimally invasive surgery with a ministernotomy (n = 196) or right minithoracotomy (n = 624) approach. Cardiopulmonary bypass and aortic cross-clamp times were 81.1 & PLUSMN; 24.3 and 50.6 & PLUSMN; 11.7 min for isolated AVR and 144.5 & PLUSMN; 34.7 and 96.4 & PLUSMN; 21.6 min for combined procedures. At mean follow-up of 53.08 & PLUSMN; 6.7 months (range: 1-120.5 months), survival was 96.5% and mean transvalvular pressure gradient was 13.7 & PLUSMN; 5.8 mmHg. Left ventricular mass decreased from 152.8 to 116.1 g/m(2) (P < 0.001) and moderate paravalvular leakage occurred in three patients without haemolysis not requiring any treatment. Freedom from reoperation was 97.6%. Eight patients required surgical reintervention and 19 patients transcatheter valve-in-valve procedure for structural prosthesis degeneration at a mean of 5.6 years after first operation (range: 2-9 years).ConclusionAVR with a Perceval bioprosthesis is associated with good clinical results and excellent haemodynamic performance in our 10-year experience. Structural degeneration rate of Perceval is comparable with other bioprosthetic aortic valves. Sutureless technology may reduce operative time especially in combined procedures and enable minimally invasive AVR.
引用
收藏
页码:506 / 513
页数:8
相关论文
共 24 条
[1]  
Akins CW, 2008, ANN THORAC SURG, V85, P1490, DOI [10.1016/j.athoracsur.2007.12.082, 10.1016/j.ejcts.2007.12.055]
[2]   Isolated aortic valve replacement in North America comprising 108,687 patients in 10 years: Changes in risks, valve types, and outcomes in the Society of Thoracic Surgeons National Database [J].
Brown, James M. ;
O'Brien, Sean M. ;
Wu, Changfu ;
Sikora, Jo Ann H. ;
Griffith, Bartley P. ;
Gammie, James S. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (01) :82-90
[3]   Increased Gradients After Aortic Valve Replacement With the Perceval Valve: The Role of Oversizing [J].
Cerillo, Alfredo Giuseppe ;
Amoretti, Francesca ;
Mariani, Massimiliano ;
Cigala, Emanuele ;
Murzi, Michele ;
Gasbarri, Tommaso ;
Solinas, Marco ;
Chiappino, Dante .
ANNALS OF THORACIC SURGERY, 2018, 106 (01) :121-128
[4]   The sutureless aortic valve at 1 year: A large multicenter cohort study [J].
Fischlein, Theodor ;
Meuris, Bart ;
Hakim-Meibodi, Kavous ;
Misfeld, Martin ;
Carrel, Thierry ;
Zembala, Marian ;
Gaggianesi, Sara ;
Madonna, Francesco ;
Laborde, Francois ;
Asch, Federico ;
Haverich, Axel .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 151 (06) :1617-+
[5]   Sutureless Valve Implantation via Mini J-Sternotomy: A Single Center Experience with 2 Years Mean Follow-up [J].
Fischlein, Theodor ;
Pfeiffer, Steffen ;
Pollari, Francesco ;
Sirch, Joachim ;
Vogt, Ferdinand ;
Santarpino, Giuseppe .
THORACIC AND CARDIOVASCULAR SURGEON, 2015, 63 (06) :467-471
[6]   Effect of sutureless implantation of the Perceval S aortic valve bioprosthesis on intraoperative and early postoperative outcomes [J].
Flameng, Willem ;
Herregods, Marie-Christine ;
Hermans, Hadewich ;
Van der Mieren, Gerry ;
Vercalsteren, Monique ;
Poortmans, Gert ;
Van Hemelrijck, Jan ;
Meuris, Bart .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 142 (06) :1453-1457
[7]   Paravalvular Leak After Transcatheter Aortic Valve Replacement The New Achilles' Heel? A Comprehensive Review of the Literature [J].
Genereux, Philippe ;
Head, Stuart J. ;
Hahn, Rebecca ;
Daneault, Benoit ;
Kodali, Susheel ;
Williams, Mathew R. ;
van Mieghem, Nicolas M. ;
Alu, Maria C. ;
Serruys, Patrick W. ;
Kappetein, A. Pieter ;
Leon, Martin B. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (11) :1125-1136
[8]   Do hospitals with low mortality rates in coronary artery bypass also perform well in valve replacement? [J].
Goodney, PP ;
O'Connor, GT ;
Wennberg, DE ;
Birkmeyer, JD .
ANNALS OF THORACIC SURGERY, 2003, 76 (04) :1131-1136
[9]  
Harold JG, 2014, J AM COLL CARDIOL, V63, pE57, DOI [10.1016/j.jacc.2014.02.536, 10.1016/j.jtcvs.2014.05.014, 10.1016/j.jacc.2014.02.537]
[10]   Long-Term Durability of Bioprosthetic Aortic Valves: Implications From 12,569 Implants [J].
Johnston, Douglas R. ;
Soltesz, Edward G. ;
Vakil, Nakul ;
Rajeswaran, Jeevanantham ;
Roselli, Eric E. ;
Sabik, Joseph F., III ;
Smedira, Nicholas G. ;
Svensson, Lars G. ;
Lytle, Bruce W. ;
Blackstone, Eugene H. .
ANNALS OF THORACIC SURGERY, 2015, 99 (04) :1239-1246