Microcirculatory response to lower body negative pressure and the association to large vessel function

被引:1
|
作者
Jonsson, Hanna [1 ]
Henricson, Joakim [2 ,3 ]
Saager, Rolf B. [1 ]
Wilhelms, Daniel [2 ,3 ]
机构
[1] Linkoping Univ, Dept Biomed Engn, Linkoping, Sweden
[2] Linkoping Univ, Dept Emergency Med Linkoping, Linkoping, Sweden
[3] Linkoping Univ, Dept Biomed & Clin Sci, Linkoping, Sweden
来源
PHOTONICS IN DERMATOLOGY AND PLASTIC SURGERY 2023 | 2023年 / 12352卷
关键词
Microcirculation; lower body negative pressure; skin; polarized reflection; spatial frequency domain imaging; DYSFUNCTION;
D O I
10.1117/12.2648028
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Vital signs reflect circulatory function and hence hemodynamics on a macroscopic scale and are often unreliable or late indicators of hemodynamic instability. Previous studies support that alterations in the microcirculation may provide early indicators of deterioration and impending shock. Microcirculation is also restored late in the recovery process. Hence, monitoring microcirculation is important since treatments based on normalizing classical vital signs will not always restore microvascular hemodynamics and the microcirculation may remain in shock although e.g., blood pressure seems normal. The aim of this study was to investigate alterations in skin microcirculation dynamics during lower body negative pressure as a model of shock and central hypovolemia. By using spatial frequency domain imaging (SFDI) and polarized reflectance imaging, we investigated the association between micro- and macrovascular function during these conditions. Furthermore, we evaluated microvascular reactivity using the capillary refill test. A cohort of 9 subjects were subjected to a progressive lower body negative pressure (LBNP) protocol. At baseline and at LBNP = -20mmHg, -30mmHg and -40mmHg, SFDI images were acquired and analyzed for tissue hemoglobin content and oxygenation. Superficial hemoglobin content was estimated by polarized reflectance imaging. We found that microcirculatory reactivity was prolonged during LBNP, but recovered after end of the protocol. These results indicate a correlation between negative pressure and microcirculatory function and that may provide a basis for early detection of shock in emergency care settings.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] The microcirculatory response to compensated hypovolemia in a lower body negative pressure model
    Bartels, Sebastiaan A.
    Bezemer, Rick
    Milstein, Dan M. J.
    Radder, Matthijs
    Lima, Alexandre
    Cherpanath, Thomas G. V.
    Heger, Michal
    Karemaker, John M.
    Ince, Can
    MICROVASCULAR RESEARCH, 2011, 82 (03) : 374 - 380
  • [2] THE MICROCIRCULATORY RESPONSE TO CONTROLLED, ADEQUATELY COMPENSATED, CENTRAL HYPOVOLEMIA IN A LOWER BODY NEGATIVE PRESSURE MODEL
    Bartels, S. A.
    Bezemer, R.
    Milstein, D. M.
    Lima, A.
    Karemaker, J. M.
    Ince, C.
    INTENSIVE CARE MEDICINE, 2011, 37 : S184 - S184
  • [3] EFFECTS OF LOWER BODY NEGATIVE PRESSURE ON RENAL FUNCTION
    GILBERT, CA
    BRICKER, LA
    STEVENS, PM
    WARREN, BH
    AEROSPACE MEDICINE, 1966, 37 (03): : 279 - +
  • [4] Ocular perfusion pressure is not reduced in response to lower body negative pressure
    Hall, Eric A.
    Whittle, Richard S.
    Diaz-Artiles, Ana
    NPJ MICROGRAVITY, 2024, 10 (01)
  • [5] Lower body negative pressure: A test of cardiovascular - Autonomic function
    Patel, AR
    Engstrom, JE
    Tusing, LD
    McNeeley, KJ
    Chelimsky, TC
    MUSCLE & NERVE, 2001, 24 (04) : 481 - 487
  • [6] Hemodynamic response to lower body negative pressure in hemodialysis patients
    Nette, RW
    Krepel, HP
    van den Dorpel, MA
    van den Meiracker, AH
    Poldermans, D
    Boomsma, F
    Weimar, W
    Zietse, R
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2003, 41 (04) : 807 - 813
  • [7] CARDIORESPIRATORY RESPONSE TO LOWER-BODY NEGATIVE-PRESSURE
    CHANG, CM
    CASSUTO, Y
    PENDERGAST, DR
    FARHI, LE
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 1994, 65 (07): : 615 - 620
  • [8] System identification of baroreflex response to mild lower body negative pressure
    Aletti, Federico
    Ferrario, Manuela
    Xu, Da
    Greaves, Danielle K.
    Shoemaker, Kevin J.
    Arbeille, Philippe
    Cerutti, Sergio
    Hughson, Richard L.
    Baselli, Giuseppe
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 2550 - 2553
  • [9] LOWER BODY NEGATIVE PRESSURE AS AN ASSAY TECHNIQUE FOR ORTHOSTATIC TOLERANCE .3. A COMPARISON OF INDIVIDUAL RESPONSE TO INCREMENTAL LEG NEGATIVE PRESSURE VS INCREMENTAL LOWER BODY NEGATIVE PRESSURE
    WOLTHUIS, RA
    HOFFLER, GW
    JOHNSON, RL
    AEROSPACE MEDICINE, 1970, 41 (12): : 1354 - &
  • [10] Sex Variations in Retinal Microcirculation Response to Lower Body Negative Pressure
    Salon, Adam
    Vladic, Nikola
    Schmid-Zalaudek, Karin
    Steuber, Bianca
    Hawliczek, Anna
    Urevc, Janez
    Bergauer, Andrej
    Pivec, Vid
    Shankhwar, Vishwajeet
    Goswami, Nandu
    BIOLOGY-BASEL, 2023, 12 (09):