Improved Chromatography and MS-Based Detection of Glyphosate and Aminomethylphosphonic Acid Using iTrEnDi

被引:8
作者
Rosales, Christian A. [1 ,2 ]
Shields, Samuel W. J. [1 ,2 ]
Aulenback, Chelsey L. J. [2 ,3 ]
Elezi, Gazmend [4 ,5 ]
Wasslen, Karl V. [1 ,2 ]
Pallister, Peter J. [1 ,2 ]
Faull, Kym F. [4 ,5 ]
Manthorpe, Jeffrey M. [1 ,3 ]
Smith, Jeffrey C. [1 ,3 ]
机构
[1] Carleton Univ, Dept Chem, Ottawa, ON K1S 5B6, Canada
[2] Carleton Univ, Carleton Mass Spectrometry Ctr, Ottawa, ON K1S 5B6, Canada
[3] Carleton Univ, Inst Biochem, Dept Chem, Ottawa, ON K1S 5B6, Canada
[4] Univ Calif Los Angeles, David Geffen Sch Med, Jane & Terry Semel Inst Neurosci & Human Behav, Pasarow Mass Spectrometry Lab, Los Angeles, CA 90024 USA
[5] Univ Calif Los Angeles, David Geffen Sch Med, Dept Psychiat & Biobehav Sci, Los Angeles, CA 90024 USA
基金
加拿大自然科学与工程研究理事会;
关键词
herbicide; glyphosate; aminomethylphosphonic acid; diazomethane; mass spectrometry; high-performance liquid chromatography; SIGNIFICANTLY ENHANCES SENSITIVITY; MASS-SPECTROMETRY ANALYSES; AMINO-GROUPS; WATER; DERIVATIZATION; DIAZOMETHANE; GLUFOSINATE; AMPA; QUATERNIZATION; SAMPLES;
D O I
10.1021/jasms.3c00026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Glyphosate (GLY), a synthetic, nonselective systemic herbicide that is particularly effective against perennial weeds, is the most used weedkiller in the world. There are growing concerns over GLY accumulation in the environment and the attendant human health-associated risks, and despite increased attention in the media, GLY and its breakdown product aminomethylphosphonic acid (AMPA) remain elusive to many analytical strategies. Chemical derivatization coupled with high-performance liquid chromatography-mass spectrometry (HPLC-MS) addresses the challenge of quantifying low levels of GLY and AMPA in complex samples. Here we demonstrate the use of in situ trimethylation enhancement using diazomethane (iTrEnDi) to derivatize GLY and AMPA into permethylated products ([GLYTr]+ and [AMPATr]+, respectively) prior to analysis via HPLC-MS. iTrEnDi produced quantitative yields and resulted in a 12-340-fold increases in HPLC-MS-based sensitivity for [GLYTr]+ and [AMPATr]+, respectively, compared with underivatized counterparts. The limits of detection of derivatized compounds were found to be 0.99 ng/L for [GLYTr]+ and 1.30 ng/L for [AMPATr]+, demonstrating significant sensitivity improvements compared to previously established derivatization techniques. iTrEnDi is compatible with the direct derivatization of Roundup formulations. Finally, as proof of principle, a simple aqueous extraction followed by iTrEnDi enabled the detection of [GLYTr]+ and [AMPATr]+ on the exterior of field-grown soybeans that were sprayed with Roundup. Overall, iTrEnDi ameliorates issues relating to low proton affinity and chromatographic retention, boosting HPLC-MS-based sensitivity and enabling the elucidation of elusive analytes such as GLY and AMPA within agricultural systems.
引用
收藏
页码:948 / 957
页数:10
相关论文
共 50 条
[41]   Determination of glyphosate and aminomethylphosphonic acid for assessing the quality tap water using SPE and HPLC [J].
Delmonico, Eduardo Luiz ;
Bertozzi, Janksyn ;
de Souza, Nilson Evelazio ;
Oliveira, Claudio Celestino .
ACTA SCIENTIARUM-TECHNOLOGY, 2014, 36 (03) :513-519
[42]   New Standardized Procedure to Extract Glyphosate and Aminomethylphosphonic Acid from Different Matrices: A Kit for HPLC-UV Detection [J].
Chiara, Francesco ;
Allegra, Sarah ;
Arrigo, Elisa ;
Di Grazia, Daniela ;
Agar, Francesco Maximillian Anthony Shelton ;
Abalai, Raluca Elena ;
Gilardi, Sara ;
De Francia, Silvia ;
Mancardi, Daniele .
JOURNAL OF XENOBIOTICS, 2025, 15 (01)
[43]   Determination of Phosphite, Phosphate, Glyphosate and Aminomethylphosphonic Acid by Two-Dimensional Ion Chromatography System Coupled with Capillary Ion Chromatography [J].
Qiu Hui-Min ;
Geng Jin-Ju ;
Han Chao ;
Ren Hong-Qiang .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (12) :1910-1913
[44]   Dynamic supported liquid membrane tip extraction of glyphosate and aminomethylphosphonic acid followed by capillary electrophoresis with contactless conductivity detection [J].
See, Hong Heng ;
Hauser, Peter C. ;
Sanagi, M. Marsin ;
Ibrahim, Wan Aini Wan .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (37) :5832-5838
[45]   High-Performance Liquid Chromatography Quantification of Glyphosate, Aminomethylphosphonic Acid, and Ascorbate in Culture Medium and Microalgal Cells [J].
Ostera, Juan Manuel ;
Olmos, Valentina ;
Puntarulo, Susana ;
Bonetto, Julian G. ;
Malanga, Gabriela .
BIO-PROTOCOL, 2025, 15 (07)
[46]   Determination of glyphosate and aminomethylphosphonic acid in soybean samples by high performance liquid chromatography using a novel fluorescent labeling reagent [J].
Zhang, Yaoyao ;
Zhang, Yi ;
Qu, Qishu ;
Wang, Guoxiu ;
Wang, Chengyin .
ANALYTICAL METHODS, 2013, 5 (22) :6465-6472
[47]   Rapid determination of glufosinate, glyphosate and aminomethylphosphonic acid in environmental water samples using precolumn fluorogenic labeling and coupled-column liquid chromatography [J].
Sancho, JV ;
Hernandez, F ;
Lopez, FJ ;
Hogendoorn, EA ;
Dijkman, E ;
vanZoonen, P .
JOURNAL OF CHROMATOGRAPHY A, 1996, 737 (01) :75-83
[48]   Direct and sensitive determination of glyphosate and aminomethylphosphonic acid in environmental water samples by high performance liquid chromatography coupled to electrospray tandem mass spectrometry [J].
Guo, Hongyue ;
Riter, Leah S. ;
Wujcik, Chad E. ;
Armstrong, Daniel W. .
JOURNAL OF CHROMATOGRAPHY A, 2016, 1443 :93-100
[49]   Development of a sensitive direct injection LC-MS/MS method for the detection of glyphosate and aminomethylphosphonic acid (AMPA) in hard waters [J].
Jake C. Ulrich ;
P. Lee Ferguson .
Analytical and Bioanalytical Chemistry, 2021, 413 :3763-3774
[50]   Development of a sensitive direct injection LC-MS/MS method for the detection of glyphosate and aminomethylphosphonic acid (AMPA) in hard waters [J].
Ulrich, Jake C. ;
Ferguson, P. Lee .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (14) :3763-3774