Distalization of hinge site with use of hinge wire reduces hinge fracture rates in closing wedge distal femoral osteotomy

被引:7
作者
Teo, Shao Jin [1 ]
Koh, Don Thong Siang [1 ]
Soong, Jun Wei [1 ]
Yeo, William [1 ]
Wilson, Adrian [2 ]
Lee, Kong Hwee [1 ]
机构
[1] Singapore Gen Hosp, Dept Orthopaed Surg, 20 Coll Rd, Singapore 169856, Singapore
[2] Basingstoke & North Hampshire Hosp, Dept Trauma & Orthopaed, Basingstoke, England
关键词
Distal femoral osteotomy; Hinge fracture; Hinge; Knee preservation; HIGH TIBIAL OSTEOTOMY; TERM-FOLLOW-UP; VARUS OSTEOTOMY; OPENING WEDGE;
D O I
10.1007/s00167-022-07286-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Closing wedge distal femoral osteotomies (CWDFO) are attractive treatment options for unicompartmental knee osteoarthritis with coronal plane deformity. However, it has been traditionally associated with high rates of hinge fracture that can adversely impact recovery and patient outcomes. Appropriate siting of hinge point can be an effective method of reducing the incidence of hinge fractures. This study aims to illustrate a case series of CWDFO with low rates of hinge fracture utilising our preferred hinge point site.Methods A retrospective study of a cohort of 39 CWDFO was performed between May 2019 and May 2022. Both medial and lateral CWDFO were included. The hinge point in all cases was placed at the level of the inferior margin of the metaphyseal flare, and inferior to the gastrocnemius origin, with a hinge thickness of 10 mm. Post-operative radiographs were obtained at 2, 4 and 8 weeks after surgery to assess for hinge fracture and union.Results Thirty-nine cases of CWDFO were performed, consisting of eighteen cases of valgus malalignment that underwent medial CWDFO and twenty-one cases of varus malalignment that underwent lateral CWDFO. At surgery, the mean age was 47.6 (+/- 13.9) years and mean BMI was 29.4 (+/- 4.9). There were 23 men and 16 women. Three cases of hinge fractures occurred intraoperatively, translating into a hinge fracture rate of 7.69%. However, union was achieved in all three cases and all patients in this case series were able to progress to weight bear as tolerated at 2 months post-osteotomy.Conclusion Distal placement of the hinge at the level of the inferior metaphyseal flare margin with the use of a hinge wire can greatly reduce the rates of hinge fracture in CWDFO.
引用
收藏
页码:3141 / 3150
页数:10
相关论文
共 26 条
  • [1] The long-term outcome of high tibial osteotomy - A ten- to 20-year follow-up
    Akizuki, S.
    Shibakawa, A.
    Takizawa, T.
    Yamazaki, I.
    Horiuchi, H.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (05): : 592 - 596
  • [2] Long-term follow-up of distal femoral varus osteotomy of the knee
    Backstein, David
    Morag, Guy
    Hanna, Samer
    Safir, Oleg
    Gross, Allan
    [J]. JOURNAL OF ARTHROPLASTY, 2007, 22 (04) : 2 - 6
  • [3] Chahla J, 2016, ORTHOP J SPORTS MED, V4
  • [4] Adding a protective K-wire during opening high tibial osteotomy increases lateral hinge resistance to fracture
    Dessyn, Edouard
    Sharma, Akash
    Donnez, Mathias
    Chabrand, Patrick
    Ehlinger, Matthieu
    Argenson, Jean-Noel
    Parratte, Sebastien
    Ollivier, Matthieu
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (03) : 751 - 758
  • [5] Varus osteotomy of the distal part of the femur - A survivorship analysis
    Finkelstein, JA
    Gross, AE
    Davis, A
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (09) : 1348 - 1352
  • [6] Midterm results following medial closed wedge distal femoral osteotomy stabilized with a locking internal fixation device
    Forkel, Philipp
    Achtnich, Andrea
    Metzlaff, Sebastian
    Zantop, Thore
    Petersen, Wolf
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (07) : 2061 - 2067
  • [7] Influence of lateral hinge fractures on biplanar medial closing-wedge distal femoral osteotomy for valgus knee: a new classification of lateral hinge fracture
    Fujita, Kenji
    Sawaguchi, Takeshi
    Goshima, Kenichi
    Shigemoto, Kenji
    Iwai, Shintaro
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (03) : 1175 - 1183
  • [8] Large opening gaps, unstable hinge fractures, and osteotomy line below the safe zone cause delayed bone healing after open-wedge high tibial osteotomy
    Goshima, Kenichi
    Sawaguchi, Takeshi
    Shigemoto, Kenji
    Iwai, Shintaro
    Nakanishi, Akira
    Inoue, Daisuke
    Shima, Yosuke
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (04) : 1291 - 1298
  • [9] A protective hinge wire, intersecting the osteotomy plane, can reduce the occurrence of perioperative hinge fractures in medial opening wedge osteotomy
    Gulagaci, Firat
    Jacquet, Christophe
    Ehlinger, Matthieu
    Sharma, Akash
    Kley, Kristian
    Wilson, Adrian
    Parratte, Sebastien
    Ollivier, Matthieu
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (10) : 3173 - 3182
  • [10] Distal femoral varus osteotomy: problems associated with the lateral open-wedge technique
    Jacobi, Matthias
    Wahl, Peter
    Bouaicha, Samy
    Jakob, Roland P.
    Gautier, Emanuel
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (06) : 725 - 728