Core-shell mesoporous silica-based ion-imprinted electrochemical sensor for the determination of trace Cd2+ in water

被引:0
|
作者
Yin, Fengqin [1 ]
Zhou, Dianli [1 ]
Mo, Yeling [1 ]
Liu, Xueting [1 ]
Li, Gaoyang [1 ]
Gao, Jiali [1 ]
Yuan, Min [1 ]
Wu, Xiuxiu [1 ]
Hao, Liling [1 ]
Xu, Fei [1 ]
机构
[1] Univ Shanghai Sci & Technol, Shanghai Engn Res Ctr Food Rapid Detect, Sch Hlth Sci & Engn, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Cadmium; Core-shell mesoporous; Ion-imprinted polymers; Electrochemical sensor; Differential pulse voltammetry; ATOMIC-ABSORPTION-SPECTROMETRY; SELECTIVE EXTRACTION; CADMIUM IONS; ULTRA-TRACE; POLYMER; SORBENT; SAMPLES; PRECONCENTRATION; REMOVAL; MICROEXTRACTION;
D O I
10.1007/s10800-023-02015-6
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A selective and sensitive ion-imprinted electrochemical sensor was proposed to detect cadmium ion (Cd2+) through differential pulse voltammetry (DPV) method based on core-shell mesoporous cadmium ion-imprinted polymers (IIP) and gold nanoparticles (AuNPs). The ion-imprinted polymers were prepared by the surface ion-imprinting technique using core-shell mesoporous silica as the carrier, Cd2+ as the template ion, and 3-mercaptopropyl trimethoxysilane (MPTMS) as the functional monomer. Due to the implementation of surface ion imprinting strategy on core-shell mesoporous structure, the polymer was endowed with excellent specific surface area and imprinted cavities, thus showing effective transmission and recognition ability for Cd2+. Furthermore, the introduction of gold nanoparticles synthesized through electrodeposition can accelerate the electron transfer rate and also increase the modified area of electrode for ion-imprinted polymers, resulting in higher sensitivity of the modified electrodes when ion-imprinted polymers was self-assembled on the surface of gold nanoparticle-modified electrode through Au-S. The linear range of the sensor varied from 1 to 100 mu g L-1, with the minimum detection limit of 0.22 mu g L-1. In addition, excellent anti-interference ability in Cd2+ detection was obtained in the presence of various interfering ions, and the sensor has also been proved to have good practicability in actual water sample detection, with the recovery rate in the range of 82.2% and 116.0% and the RSD is in the range of 0.33-7.30%. Therefore, this work is expected to provide an electrochemical sensor with excellent selectivity, good stability, and sensitivity for detecting trace Cd2+ in real-water samples.{GRAPHIACAL ABSTRACT}
引用
收藏
页码:1125 / 1135
页数:11
相关论文
共 50 条
  • [41] Flow injection chemiluminescence sensor based on core-shell magnetic molecularly imprinted nanoparticles for determination of chrysoidine in food samples
    Lu, Fuguang
    Sun, Min
    Fan, Lulu
    Qiu, Huamin
    Li, Xiangjun
    Luo, Chuannan
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 173 : 591 - 598
  • [42] Zinc ion-imprinted polymer based on silica particles modified carbon paste electrodes for highly selective electrochemical determination of zinc ions
    Khairnar, Nilesh A.
    Jirimali, Harishchandra D.
    Patil, Kailas P.
    Gite, Vikas V.
    POLYMER-PLASTICS TECHNOLOGY AND MATERIALS, 2020, 59 (15): : 1698 - 1714
  • [43] A novel electrochemical imprinted sensor for acetylsalicylic acid based on polypyrrole, sol-gel and SiO2@Au core-shell nanoparticles
    Deiminiat, Behjat
    Razavipanah, Iman
    Rounaghi, Gholam Hossein
    Arbab-Zavar, Mohammad Hossein
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 244 : 785 - 795
  • [44] A novel voltammetric methodology based on a methacrylic acid/2-methyl thiophene ion-imprinted polymer sensor for the determination of As(III) in water samples
    Rebolledo-Perales, Luz E.
    Galan-Vidal, Carlos A.
    Perez-Silva, I.
    Hernandez-Ramirez, Daniel
    Guzman, Miriam Franco
    Islas, Gabriela
    Ortega, Israel S. Ibarra
    Romero, Giaan A. Alvarez
    ELECTROCHIMICA ACTA, 2025, 524
  • [45] CORE-SHELL POLYMER PARTICLES AS A FRET-BASED RATIOMETRIC SENSOR FOR MERCURY ION DETECTION IN WATER
    Liu, Yan
    Ma, Chao
    Zeng, Fang
    Wu, Shui-zhu
    ACTA POLYMERICA SINICA, 2012, (06) : 666 - 672
  • [46] Electrochemical sensor based on graphdiyne is effectively used to determine Cd2+ and Pb2+ in water
    Li, Ying
    Huang, Huan
    Cui, Rongli
    Wang, Dongmei
    Yin, Zi
    Wang, Dan
    Zheng, Lirong
    Zhang, Jing
    Zhao, Yidong
    Yuan, Hui
    Dong, Jinquan
    Guo, Xihong
    Sun, Baoyun
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 332
  • [47] Preparation of silica-based surface-imprinted core-shell nanoadsorbents for the selective recognition of sulfamethazine via reverse atom transfer radical precipitation polymerization
    Zou, Tianbian
    Zhou, Zhiping
    Dai, Jiangdong
    Gao, Lin
    Wei, Xiao
    Li, Chunxiang
    Guan, Weixing
    Yan, Yongsheng
    JOURNAL OF POLYMER RESEARCH, 2014, 21 (08)
  • [48] One-step synthesis of periodic ion imprinted mesoporous silica particles for highly specific removal of Cd2+ from mine wastewater
    Li, Weiming
    He, Rong
    Tan, Lei
    Xu, Shiying
    Kang, Chengcheng
    Wei, Chaohai
    Tang, Youwen
    JOURNAL OF SOL-GEL SCIENCE AND TECHNOLOGY, 2016, 78 (03) : 632 - 640
  • [49] One-step synthesis of periodic ion imprinted mesoporous silica particles for highly specific removal of Cd2+ from mine wastewater
    Weiming Li
    Rong He
    Lei Tan
    Shiying Xu
    Chengcheng Kang
    Chaohai Wei
    Youwen Tang
    Journal of Sol-Gel Science and Technology, 2016, 78 : 632 - 640
  • [50] A Hydrogen Peroxide Electrochemical Sensor Based on Core-Shell MnO2-SiO2-Ag Nanocomposite