A performance comparison of heterostructure surface plasmon resonance biosensor for the diagnosis of novel coronavirus SARS-CoV-2

被引:34
作者
Akib, Tarik Bin Abdul [1 ,2 ]
Mostufa, Shahriar [1 ]
Rana, Md. Masud [1 ]
Hossain, Md. Biplob [3 ,4 ]
Islam, Md. Rabiul [3 ]
机构
[1] Rajshahi Univ Engn & Technol, Dept Elect & Elect Engn, Rajshahi 6204, Bangladesh
[2] Bangladesh Army Univ Engn & Technol, Dept Elect & Elect Engn, Rajshahi 6431, Bangladesh
[3] Univ Wollongong, Fac Engn & Informat Sci, Wollongong, NSW 2522, Australia
[4] Jashore Univ Sci & Technol, Dept Elect & Elect Engn, Jashore 7408, Bangladesh
关键词
Biosensor; Finite-difference time-domain (FDTD); SARS-CoV-2; virus; Surface plasmon resonance; 2D materials; Transfer matrix method; REFRACTIVE-INDEX SENSITIVITY; HYBRID NANOSTRUCTURES; GRAPHENE; DESIGN; SENSOR; ENHANCEMENT;
D O I
10.1007/s11082-023-04700-4
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a performance comparison of heterostructure surface plasmon resonance (SPR) biosensors for the application of Novel Coronavirus SARS-CoV-2 diagnosis. The comparison is performed and compared with the existing literature based on the performance parameters in terms of several prisms such as BaF2, BK7, CaF2, CsF, SF6, and SiO2, several adhesion layers such as TiO2, Chromium, plasmonic metals such as Ag, Au, and two-dimensional (2D) transition metal dichalcogenides materials such as BP, Graphene, PtSe2 MoS2, MoSe2, WS2, WSe2. To study the performance of the heterostructure SPR sensor, the transfer matrix method is applied, and to analyses, the electric field intensity near the graphene-sensing layer contact, the finite-difference time-domain approach is utilized. Numerical results show that the heterostructure comprised of CaF2/TiO2/Ag/BP/Graphene/Sensing-layer has the best sensitivity and detection accuracy. The proposed sensor has an angle shift sensitivity of 390 degrees/refractive index unit (RIU). Furthermore, the sensor achieved a detection accuracy of 0.464, a quality factor of 92.86/RIU, a figure of merit of 87.95, and a combined sensitive factor of 85.28. Furthermore, varied concentrations (0-1000 nM) of biomolecule binding interactions between ligands and analytes have been observed for the prospects of diagnosis of the SARS-CoV-2 virus. Results demonstrate that the proposed sensor is well suited for real-time and label-free detection particularly SARS-CoV-2 virus detection.
引用
收藏
页数:38
相关论文
共 102 条
[51]   Highly Sensitive TiO2/Au/Graphene Layer-Based Surface Plasmon Resonance Biosensor for Cancer Detection [J].
Mostufa, Shahriar ;
Akib, Tarik Bin Abdul ;
Rana, Md Masud ;
Islam, Md Rabiul .
BIOSENSORS-BASEL, 2022, 12 (08)
[52]   Numerical approach to design the graphene-based multilayered surface plasmon resonance biosensor for the rapid detection of the novel coronavirus [J].
Mostufa, Shahriar ;
Akib, Tarik Bin Abdul ;
Rana, Md Masud ;
Mehedi, Ibrahim M. ;
Al-Saggaf, Ubaid M. ;
Alsaggaf, Abdulrahman U. ;
Alsaggaf, Mohammed U. ;
Alam, Md. Sarowar .
OPTICS CONTINUUM, 2022, 1 (03) :494-515
[53]   Detection of hemoglobin in blood and urine glucose level samples using a graphene-coated SPR based biosensor [J].
Mostufa, Shahriar ;
Paul, Alok Kumar ;
Chakrabarti, Kisalaya .
OSA CONTINUUM, 2021, 4 (08) :2164-2176
[54]   Nano-layered surface plasmon resonance-based highly sensitive biosensor for virus detection: A theoretical approach to detect SARS-CoV-2 [J].
Moznuzzaman, Md ;
Khan, Imran ;
Islam, Md Rafiqul .
AIP ADVANCES, 2021, 11 (06)
[55]   Modeling of highly improved SPR sensor for formalin detection [J].
Moznuzzaman, Md ;
Islam, Md Rafiqul ;
Hossain, Md Biplob ;
Mehedi, Ibrahim Mustafa .
RESULTS IN PHYSICS, 2020, 16
[56]   Impact of Taguchi Optimization in Fiber Surface Plasmon Resonance Sensors Based on Si3N4 Layer [J].
Mudgal, N. ;
Choure, Kamal Kishor ;
Falaswal, Manoj Kumar ;
Pandey, Rahul ;
Agarwal, Ankit ;
Bhatia, Dinesh ;
Saharia, Ankur ;
Sahu, Saurabh ;
Singh, G. .
BRAZILIAN JOURNAL OF PHYSICS, 2022, 52 (03)
[57]   Sensitivity enhancement with anti-reflection coating of silicon nitride (Si3N4) layer in silver-based Surface Plasmon Resonance (SPR) sensor for sensing of DNA hybridization [J].
Mudgal, N. ;
Saharia, Ankur ;
Choure, Kamal Kishor ;
Agarwal, Ankit ;
Singh, G. .
APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2020, 126 (12)
[58]   Modeling of highly sensitive surface plasmon resonance (SPR) sensor for urine glucose detection [J].
Mudgal, N. ;
Saharia, Ankur ;
Agarwal, Ankit ;
Ali, Jalil ;
Yupapin, Preecha ;
Singh, G. .
OPTICAL AND QUANTUM ELECTRONICS, 2020, 52 (06)
[59]   Black Phosphorus Nanostructure Based Highly Sensitive and Selective Surface Plasmon Resonance Sensor for Biological and Chemical Sensing: A Review [J].
Nangare, Sopan ;
Patil, Pravin .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2023, 53 (01) :1-26
[60]   A transfer function approach to the small-signal response of saturated semiconductor optical amplifiers [J].
Nielsen, ML ;
Blumenthal, DJ ;
Mork, J .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 2000, 18 (12) :2151-2157