A performance comparison of heterostructure surface plasmon resonance biosensor for the diagnosis of novel coronavirus SARS-CoV-2

被引:34
作者
Akib, Tarik Bin Abdul [1 ,2 ]
Mostufa, Shahriar [1 ]
Rana, Md. Masud [1 ]
Hossain, Md. Biplob [3 ,4 ]
Islam, Md. Rabiul [3 ]
机构
[1] Rajshahi Univ Engn & Technol, Dept Elect & Elect Engn, Rajshahi 6204, Bangladesh
[2] Bangladesh Army Univ Engn & Technol, Dept Elect & Elect Engn, Rajshahi 6431, Bangladesh
[3] Univ Wollongong, Fac Engn & Informat Sci, Wollongong, NSW 2522, Australia
[4] Jashore Univ Sci & Technol, Dept Elect & Elect Engn, Jashore 7408, Bangladesh
关键词
Biosensor; Finite-difference time-domain (FDTD); SARS-CoV-2; virus; Surface plasmon resonance; 2D materials; Transfer matrix method; REFRACTIVE-INDEX SENSITIVITY; HYBRID NANOSTRUCTURES; GRAPHENE; DESIGN; SENSOR; ENHANCEMENT;
D O I
10.1007/s11082-023-04700-4
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a performance comparison of heterostructure surface plasmon resonance (SPR) biosensors for the application of Novel Coronavirus SARS-CoV-2 diagnosis. The comparison is performed and compared with the existing literature based on the performance parameters in terms of several prisms such as BaF2, BK7, CaF2, CsF, SF6, and SiO2, several adhesion layers such as TiO2, Chromium, plasmonic metals such as Ag, Au, and two-dimensional (2D) transition metal dichalcogenides materials such as BP, Graphene, PtSe2 MoS2, MoSe2, WS2, WSe2. To study the performance of the heterostructure SPR sensor, the transfer matrix method is applied, and to analyses, the electric field intensity near the graphene-sensing layer contact, the finite-difference time-domain approach is utilized. Numerical results show that the heterostructure comprised of CaF2/TiO2/Ag/BP/Graphene/Sensing-layer has the best sensitivity and detection accuracy. The proposed sensor has an angle shift sensitivity of 390 degrees/refractive index unit (RIU). Furthermore, the sensor achieved a detection accuracy of 0.464, a quality factor of 92.86/RIU, a figure of merit of 87.95, and a combined sensitive factor of 85.28. Furthermore, varied concentrations (0-1000 nM) of biomolecule binding interactions between ligands and analytes have been observed for the prospects of diagnosis of the SARS-CoV-2 virus. Results demonstrate that the proposed sensor is well suited for real-time and label-free detection particularly SARS-CoV-2 virus detection.
引用
收藏
页数:38
相关论文
共 102 条
[1]   Rhodium Plasmonics for Deep-Ultraviolet Bio-Chemical Sensing [J].
Ahmadivand, Arash ;
Sinha, Raju ;
Kaya, Serkan ;
Pala, Nezih .
PLASMONICS, 2016, 11 (03) :839-849
[2]   Design and Numerical Analysis of a Graphene-Coated SPR Biosensor for Rapid Detection of the Novel Coronavirus [J].
Akib, Tarik Bin Abdul ;
Mou, Samia Ferdous ;
Rahman, Md Motiur ;
Rana, Md Masud ;
Islam, Md Rabiul ;
Mehedi, Ibrahim M. ;
Mahmud, M. A. Parvez ;
Kouzani, Abbas Z. .
SENSORS, 2021, 21 (10)
[3]   A Short Review on the Role of the Metal-Graphene Hybrid Nanostructure in Promoting the Localized Surface Plasmon Resonance Sensor Performance [J].
Alharbi, Raed ;
Irannejad, Mehrdad ;
Yavuz, Mustafa .
SENSORS, 2019, 19 (04)
[4]   Graphene-based hybrid materials and devices for biosensing [J].
Artiles, Mayra S. ;
Rout, Chandra Sekhar ;
Fisher, Timothy S. .
ADVANCED DRUG DELIVERY REVIEWS, 2011, 63 (14-15) :1352-1360
[5]   Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2): An overview of viral structure and host response [J].
Astuti, Indwiani ;
Ysrafil .
DIABETES & METABOLIC SYNDROME-CLINICAL RESEARCH & REVIEWS, 2020, 14 (04) :407-412
[6]  
Ball V, 1998, BIOPOLYMERS, V46, P489
[7]   Enhanced refractive index sensitivity of elevated short-range ordered nanohole arrays in optically thin plasmonic Au films [J].
Bochenkov, Vladimir E. ;
Frederiksen, Maj ;
Sutherland, Duncan S. .
OPTICS EXPRESS, 2013, 21 (12) :14763-14770
[8]   SPR microscopy and its applications to high-throughput analyses of biomolecular binding events and their kinetics [J].
Campbell, Charles T. ;
Kim, Gibum .
BIOMATERIALS, 2007, 28 (15) :2380-2392
[9]   Performance Comparison of Two Sensors Based on Surface Plasmon Resonance in a Plastic Optical Fiber [J].
Cennamo, Nunzio ;
Massarotti, Davide ;
Galatus, Ramona ;
Conte, Laura ;
Zeni, Luigi .
SENSORS, 2013, 13 (01) :721-735
[10]   Long range surface plasmon resonance for increased sensitivity in living cell biosensing through greater probing depth [J].
Chabot, Vincent ;
Miron, Yannick ;
Grandbois, Michel ;
Charette, Paul G. .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 174 :94-101